Toshiba f97e918 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97E918
SUBJECT
MODEL
CATEGORY
To improve the reliability
UA710061~
CONTENT
Symptom When making multi-page enlargement in the digital art function, C3300(scan trigger input failure) may appear.
Cause When making multi-page enlargement, how many areas the original is divided into (2~36) in order to read the image is determined based on a combination of original size and reproduction ratio. After the start key is pressed, the developing process is done in the order of C->M->Y->BK, so the scanning and returning operation is repeated by the scanner. The order of the area to be read starts from the rear of the original scale side to the front, then to the trailing edge of the scanning direction (If the area is divided into four, the order is as shown in the figure below). As the scanner returns even after BK is developed, depending on original size and reproduction ratio it takes too long to move the scanner to the scanning start position of the next area when the area is changed to the scanning direction (Move from "2" to "3" in the figure above), which causes the error C3300.
FC70
FIELD APPLICATION
To be applied when necessary
FACTORY APPLICATION
Scanning
Date
UNIT
Software
97/07/02
-----
Returning
Original scale
Countermeasure The programs of the software of IC93C(02) and IC94C(03) on the printed board C(01) have been changed so that the scanner will not return after developing Bk.
Change of Parts
Page No. Current New New Parts Name Interchange-ab
ility 6 1 4402404420 4402424440 PW BOARD-C B 6 8 4402414300 4402424450 IC B 6 9 4402414310 4402424460 IC B
Remarks
BSI No. F97E918 Page 2