BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97E911
SUBJECT
MODEL
CATEGORY
Safety standard Related
From Apr. 1997 (But the ground wire for AUD,TWD, SAD,ASD destinations is from May 1997 )
CONTENT
A new sorter (MG2014) is now available as an option attachable to the 6560. If the electrical noise is measured for the safety standard(VCCI,FCC,EMI) , the margin is not sufficient in comparison with the standard passing level. In order to increase the margin, a ground wire has been added to the gap between the control panel inner cover and the copier frame (TAD,CSD,AUD,TWD,SAD,ASD:regions only) and between the LCD and the control panel stay (AUD,TWD,SAD,ASD : regions only).
With the addition of the ground wire, a ground hole has been added to the inner cover and the control panel bracket (right), and these parts number has been changed. But for areas where a ground wire is not used (EUD,GSD,FSD,SED,UKD), to obtain parts standardization, the new parts are applied.
6560
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
97/06/27
UNIT
Display Unit
DTM-F7310/7417
[ Figure : Connection between the control panel inner cover and the copier ] (Only for these regions : TAD,CSD,AUD,TWD,SAD,ASD)
Control panel bracket (right)
BSI No. F97E911 Page 2
Inner cover
Ground wire
Connect to the copier (See below)
Inner cover on the right
Inner cover
[ Figure : Connection between the LCD and the control panel ] (Only for these regions : AUD, TWD, SAD, ASD)
Hinge on the right
Setscrew
Ground wire