BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97E908
SUBJECT
Complying with the Energy-Star (Tier 2)
MODEL
CATEGORY
Safety standard Related
From May 1997 / ME711921
CONTENT
For complying with the energy-star (Tier 2), the following parts have been changed for 100V series
(TAD, CSD, TWD, SAD) as well as those shown below.
Due to parts standardization with 200V series, some parts have been changed for all versions.
1) 2 stays (Items 4,5)
2) Logic PC board (Items 7,8,9)
(The interchangeability in the table below is for the 100V series and for 200V destinations the
interchangeability for the stays and logic PC board is "E".)
6560
FIELD APPLICATION
Others
FACTORY APPLICATION
Date
97/06/23
UNIT
Electrical Circuit
DTM-F7303/7310
Parts Name Current New Remarks Interchang
1 SSR ------- 3037885416
TY-TSS8J48SR
2 Screw ------- 4842040692
TZPAN3008MSZN3L
3 Screw ------- 4842040481
THPAN3008MSZN3L
4 STAY
(High
Voltage
Transformer)
5 STAY
(Transformer
box)
6 Harness 4401796220
7 Logic PC 4402321270
8 Logic PC
board
9 Resistance
(R97)
4401911280
STAY-HVT-TR
4401776570
STAY-TR-BOX
WH-PFC-AJSW-15
0
PWA-F-LGC-154
4402321470
PWB-F-LGC-154
4843072154
RTP-2B2A391JDT
4402310990
STAY-HVT-TR
4402310950
STAY-TR-BOX
4402322060
WH-PFC-AJSW-154
4402321320
PWA-F-LGC-154
4402321500
PWB-F-LGC-154
-------
(Removed)
SSR added
(Only 100V series)
Each one screw for
fixing the SSR
(Only 100V series)
Addition of hole for
screw for SSR. (For
all regions)
Addition off escape
hole for screw for
SSR
(For all regions)
Insulating tube added
(Only 100V series)
Resistor (R97)
deleted
(For all regions)
Changed pattern for
|R97| deleted (For all
regions)
Deleted
(For all regions)
e-ability
D
---
B
B
B
B
B
---
BSI No. F97E908 Page 2
Added SSR
[ Changes to the AC line ]
Addition of the Insulating tube
in the harness portion
Hole for installing
stay to SSR.
SSR
Added
(Only 100V series)
Correction of errors