Toshiba f97d879 Service Note

BSI(Service Note) TOSHIBA
TOSHIBA TEC CORPORATION
2-4-1, Shibakoen, Minato-ku, TOKYO, 105-8524 JAPAN
BSI No
F97D879
Change of the PROM
MODEL
CATEGORY
To improve the reliability
Version 070 : From Feb. Version 080 : From Mar.
CONTENT
Change of the following PROM
1) Change to version 070
4401978430 PRA-T210UC-060 4401978440 PRA-T210GDF-060
4401978450 PRA-T210GFS-060
2060, 2860, 2870
FIELD APPLICATION
Others
FACTORY APPLICATION
Current New Destination
4401978480 PRA-T210UC-070 4401978490 PRA-T210GDF-070
4401978500 PRA-T210GFS-070
NAD
MJD,MFD,UKD,ASD,SAD , TWD AUD
Date
UNIT
Software
97/05/20
DTM-F212,F7307
The underlined parts names "PRA-T210**(*)-070" have been typed the above ROM Label. <Change of contents> (1) Correction of errors in AMS (automatic magnification selection)( For Models : 2860. 2870)
When AMS was used with copiers without a document feeder, the magnification has been in correctly set. This has now been revised and the right message is now displayed.
(2) A setting code for the use of the function clear mode when there is no key copy counter has been
added. When there is no key copy counter inserted, an setting mode 08 code 133 has been added to
enable the use of or nonuse of the function clear mode. Input value = 0 : Machines which have no key copy counter inserted can use the function clear
mode.
1 : Machines which have no key copy counter inserted cannot use the function
clear mode. .
2) Change to Version 080 Current New Destination
4401978480 PRA-T210UC-070
4401978610 PRA-T210UC-080
NAD
BSI No. F97D879 Page 2
4401978490 PRA-T210GDF-070 4401978500 PRA-T210GFS-070
New
(Service Parts only)
New
(Service Parts only)
New
(Service Parts only)
4401978620 PRA-T210GDF-080 4401978630 PRA-T210GFS-080
4401978540 PRA-T210IEP-080 4401978550 PRA-T210NDP-080 4401978560 PRA-T210SNF-080
MJD,MFD,UKD,ASD,SAD, TWD AUD
Italian, Spanish Portuguese Dutch, Danish, Polish
Swedish, Norwegian, Finnish
The underlined parts names "PRA-T210**(*)-080" have been typed in the above ROM Label. [ Change of Contents ]
(1) Countermeasures to poor fixing for paper which is narrower than the width of B4 size.
When multicopying is performed with paper which is narrower than the width of B4 size, depending on the type of paper or original use, poor fixing could occur. As a counter measure to this, a method of controlling the fixing temperature has been changed.
(2) Addition of PROM service parts in various languages
A PROM in various European languages has been added to the service parts.
[ Note ]
In multicopying , the temperature of the edge of the heat roller rises, and it is necessary to prevent damage to the components. So a system to control the fall of the temperature has been for these models as follows.
( Step 1 ) At the 20th sheet or whenever thermistor 2 determines 230OC , whichever is quicker
: T - 10OC = 190OC ( If the set temperature : T is 200OC )
( Step 2)At the 30th sheet or whenever thermistor 2 determines 235 OC whichever is quicker
: T - 20OC = 180OC ( If the set temperature : T is 200OC)
( Step 3 ) 70th sheet ( Changed at the 1000th sheet )
: T - 30 OC = 170OC ( If the set temperature : T is 200OC ) But step 3 only occurs if the width of the paper is narrower than the width of B4 size ( B4, A4-R, A5-R, LG, LT-R, ST-R, etc.)
If the set temperature of the heater is 200 OC ( setting mode 08 code 6 : input value is " 6 ". )
Set Temperature :
( 1 step ) : ( 2 step ) : ( 3 step ) :
200OC
20th sheet / 230
190 OC
30th sheet / 235
O
C control
180 OC
O
C
control
170 OC
70th sheet (Changed at the 1000th sheet)