Publish Date: 99/05/21
.
.
BSI No.: M-FSA29018
Subject:
Changing the ROM (for DE/GB)
Model: TF831, TF861
Category Field Application Unit
Modification of Software (ROM) To be applied when necessary ROM
Factory Application: From the production of June, 1999
CONTENT
1. Reason for Modification
1.1 Added the new functions
(1) Separator Page between received documents.
(2) Line Monitor set permanently by the customer.
(3) Forced-print out function in security RX.
.
.
.
.
(4) Changing the destination of Recovery Transmission.
1.2 Improved items requested by TSB
(1) Changing the number of received pages to 3 digits.
(2) Changing the indication of the year to 4 digits on lists and reports.
(3) LCD indication and operation when [JOB STATUS] key is pressed.
(4) Supported V34 for PC transmission.
(5) Enable PC Printing during Secure Receive.
(6) Changed Prompts. Mb -> MB
(7) When Reception Collate Printing function is ON, the machine prints the job in the
order the machine completed receiving the job.
(8) Indicate the error code, STATUS (OK, NG) on Memory Transmission Report.
(9) Indicate department name in TTI which controls department.
(10) Widen scan width a few mm.
(11) Reduction rate from LEGAL to LETTER was changed from 75% to 73% on reception.
(12) When PC printing using MS WORD, the page can be printed in 11, 22, 33 collated
way.
2. Details of Modification
Location (IC No. / Unit name): ROM1, ROM2, ROM3 / Main PC board
Change of ROM version (Check Sum):
ROM1 (TF831) "1ACWWTS2o" (9250) ---> "1ACWWTS5a" (4B81)
ROM1 (TF861) "1ABWWTS2o" (924E) ---> "1ABWWTS5a" (4B7F)
ROM2 (Common) "2AAWWTS2o" (53C7) ---> "2AAWWTS5a" (212E)
ROM3 (DE only) "3ABEUTS1dAA" (31B1) ---> "3ABEUTS4bAA" (9701)
Note: The above change of ROMs are applied to the machines that the new type CIS
unit installed only.
Attached Files