Toshiba A29004 Service Note

Publish Date: 99/02/26
.
.
BSI No.: A29004 Subject:
Changing the ROM (for FR)
Model: TF610
Category Field Application Unit
Modification of Software (ROM) To be applied when necessary ROM
Factory Application: From the production of February, 1998
CONTENT
1. Reason for Modification
Software bug will be improved as mentioned below. When the following conditions overlap while some jobs had remained, a machine will not
carried out dialing for next transmission jobs. In case of this condition, LCD continues to display "Date & Time XX% (not 100%)".
However, functional recovery was carried out with power supplies ON/OFF.
.
. .
Condition: This problem is generated only when the transmission report after transmission or
Broadcast report is registered Into the 64th printing cue at that time. It Is no problem. If either report Is registered Into cue buffer of No.00-63. So when operator sets parameter confirmation report to "ON", rate of occurrence will be Increased.
2. Details of Modification
Location (IC No. / Unit name): ROM1 / Main PC board Change of ROM version (Check Sum):
"1223K4TSFR09B31b" (A700) ---> "1320K4TSFR10B41c" (CF00)
Attached Files
None
Loading...