Publish Date: 99/06/18
.
.
BSI No.: A29002
Subject:
Change the Service Manual
Model: TF471, TF478
Category Field Application Unit
Modification/Correction of
Service Manual
Factory Application:
To be applied immediately Operator's Manual/Service
CONTENT
1. Document No.
For TAIS
For except TAIS
Change the SJ1 and SJ2 jumper settings for EUR1, AT, PT, and ES.
E0-26151
E0-26147
.
.
.
.
Manual
See attached Table 1 on page 8-17.
2. Reason for Change
Acquisition of Spanish standard.
Attached Files
TF471/TF478
Installation:
NOTE: With EU/AU models NCU PBA, set the jumper pins for country setting by referring
to the table below.
Table 1: Jumper setting
DE GB IT FR AU EUR1 AT PT E S EUR2 SE NL DK CH FI NO BE
SJ1—————MOUAABMOUBBBBBBA
SJ2—————MOUAABMOUAAAAAAC
SJ3————— ————MOUAAAAAAC
SJ4————— ————MOUAAAAAAB
SJ5 — — — — — MOU B C C MOU A A A A A C C
SJ6—————MOUBCCMOUBBBBBBB
NOTE 1: Initial setting for EUR1 is AT.
NOTE 2:Initial setting for EUR 2 is SE.
(1) Fit the bottom of the NCU PBA to the guide of the base, and install the NCU PBA using the one
screw.
NCU PBA
Guide
TF471 US/CA/AU models and TF478 model
8-2-18-1.eps
8-2-18-2.eps
TF471 EU model
Fig. 8-2-18
SERVICE MANUAL 8-17 Chapter 8