Toshiba 3R-MV User Manual

Page 1
TOSHIBA
17

MEDIUM VOLTAGE DRIVES

MTX
NEMA 3R MV
NEMA 3R / UL Rain Tight Enclosure Ratings 4160 V at 500, 1000, and 1500 HP 50°C Ambient Rating
Neutral Point Clamp Eliminates Common Mode Voltage
Innovative Design for Use in the Desert, Jungle, or Anywhere in Between
Reliability/n motion^
Page 2
MTX NEMA 3R MV
Horsepower
500 HP
1000 HP 107 x 168 x 63 1500 HP
Liquid Crystal Display/ Electronic Operator Interface (LCD EOI )
LED Indications Keys Push Button Analog Outputs Analog Inputs Digital Inputs Digital Outputs
Enclosure Panel Construction Color
Ambient Temperature Humidity Altitude Installation Typical Applications Standards Components and Others
4 x 20 Graphical Backlit LCD Display. Ability to Display Multiple Parameters on one Screen. Flash Upgradeable Software. Includes Multi-Function Rotary Encoder and Ethernet PC Interface
Run (Red) / Stop (Green), Remote / Local, Indication of Inverter Status Local / Remote, Monitor/Program, Run, Enter, ESC, Stop / Reset, Up, Down Illuminated Interlock and Fault Reset Push Buttons Eight Selectable Voltage or Current Output Signals with Programmable Functions Two Selectable Voltage or Current Input Signals Eight Digital Inputs with Programmable Functions Six Available Digital Outputs with Programmable Functions (One used internal to drive.)
Type 3R Free Standing, Front-Maintenance Type, Top or Bottom Access for Motor and Power Cables Bright White
0 to 50‘C Maximum 95% (No Condensation) 1000 m Above Sea Level or Less Outdoor Fan, Blower, Pump, Compressor, Extruder, Options for Submersible Puming Applications Electrical Performance: NEC, ANSI NEC, NEMA, UL, CUL
**Typical HP rating of a 4 pole motor. Contact factory for applications on constant torque loads.
H x W x D (in) Weight (lb)
Construction
Ambient Conditions
15000
MTX - a New Benchmark
in Deliverable Medium
Voltage Technology
Toshiba proudly introduces the MTX N3R Outdoor Medium Voltage ASD. The MTX is the world's first ASD specifically designed for outdoor mounting in remote applications or applications where a building does not exist. It features an innovative enclosure design and power section topology that is unprecedented in the medium voltage ASD arena.
The MTX is two enclosure types married together. The transformer section is convection cooled. There are no moving parts, and heat is eliminated through passive vents at the top of the drive. The inverter section is forced cooled. Power modules are designed with the heat sinks out-the-back to send waste heat to the atmosphere. The interior of the inverter section is cooled using plate-type heat exchanger(s) so it remains cool and clean without introducing outside air.
The new topology is a logical progression of the proven T300M design in a UL rain tight enclosure. Additionally, you will achieve a lower cost of ownership with the MTX because heat removal
from a building-based drive is eliminated.
ADJUSTABLE SPEED DRIVES MOTORS CONTROLS UPS INSTRUMENTATION PLC
TOSHIBA
Available Through:
TOSHIBA INTERNATIONAL CORPORATION
INDUSTRIAL DIVISION
13131 West Little York Road, Houston, Texas 77041
Tel 713/466-0277 Fax 713/466-8773
US 800/231-1412 Canada 800/872-2192 Mexico 01/800/527-1204 www.toshiba.com/ind Copyright 10/2006
Loading...