MODEL PS-5
MAX. CAPACITY 5 kg, 10 lb, 160 oz
MIN. DIVISION 0.005 kg, 0.01 lb, 0.2 oz
MAX. TARE 5 kg, 10 lb, 160 oz
OPERATION TEMPERATURE RANGE 14 TO 104 ºF ( -10 TO 40ºC)
STORAGE TEMPERATURE RANGE
-4 TO 122 ºF ( -20 TO 50ºC)
AC/DC POWER SUPPLY :
DIMENTIONS
NOTE : THIS PRODUCT'S SERIAL NUMBER CAN BE FOUND UNDER THE PLATE
HOLDER ON THE CABINET OF THE SCALE. WE SUGGEST THAT YOU WRITE DOWN
THAT SERIAL NUMBER AND THE CORRESPONDING MODEL IN THE FOLLOWING
BLANKS AND KEEP THEM AS PERMANENT PROOF OF YOUR ACQUISITION, TO HELP
IN THE IDENTIFICATION IN CASE OF LOSS OR FURTHER CONSULTATIONS.
TELEPHONE________________________________________________________________
DATE OF
PURCHASE:________________________________________________________________
MODEL:____________________________________________________________________
SERIAL NUMBER: ___________________________________________________________
OUTPUT 9 Vd.c. 500 mA.
U
L
APPROVED
FABRICANTES DE BASCULAS TORREY
S.A. DE C.V.
ELECTRONIC SCALE
PS SERIESPS SERIES
USER MANUAL
IMPORTANT:
BEFORE OPERATING THIS SCALE, PLEASE READ THIS MANUAL THOROUGHLY.
REVISION: 1.0
Page 2
THERE IS NO
CHECK THAT THE AC/DC POWER SUPPLY
LDER
IS OBSTRUCTING
DEAR COSTUMER:
WE APPRECIATE YOUR PREFERENCE. YOU HAVE JUST ACQUIRED A TORREY
ELECTRONIC SCALE, INTERNATIONAL DISTINGUISHED FOR ITS PRECISION AND
QUALITY.
WITHOUT DOUBT, WE ASSURE THAT YOU WILL BE PLENTY SATISFIED WITH YOUR
NEW ACQUISITION.
INTRODUCTION
THE ELECTRONIC SCALE PS-5 IS AN EASY USE PRODUCT. IT COULD BE USED IN THE
PORTIONING FOR AN EXACT CONTROL IN THE WEIGH, SUPPORT IN NUTRITIONAL
CONTROL, DIETETIC CONTROL AND A WITHOUT ENDED APPLICATIONS IN THE
WEIGHT. IT HAS THE TARE FUCTION, USED WHEN YOU DON’T WANT TO TAKE INTO
ACCOUNT THE RECIPIENT WEIGHT. IT HAS THE CAPABILITY OF INTERCHANGE THE
UNITS FROM KILOGRAMS, POUNDS OR OUNCES, IT COULD BE EASY TRANSPORTED
BECAUSE IT CAN WORK WITH A 9 VOLT BATTERY (NO INCLUDED), IT HAS A
VOLTAGE SENSOR FOR THE BATTERY AND IT SHOWS TO THE USER IMPORTANT
MESSAGES.
ELEMENT CHECK LIST
IN YOUR PURCHASE YOU SHOULD RECEIVE:
• PS-5 SCALE
• PLATE
• AC/DC ADAPTOR 120 VAC/9 VDC.
• USER MANUAL
8
2
3
1
PART IDENTIFICATION
1.- CABINET: MANUFACTURED IN STAINLESS STEEL RESI STANT TO
CORROSION AND STROKES
2.- PLATE: ALSO MANUFACTURED IN STAINLESS STEEL WITH THE BORDER
BENT AND ROUNDED.
MAINTENANCE AND CLEANING.
• DO NOT PUT OVERWEIGH OVER THE SCALE
• NEVER PRESS THE KEYBOARD WITH OBJECTS SUCH AS PENCILS, PENS, KNIVES,
ETC.
• DO NOT DROP HARD THE PRODUCT TO BE WEIGHTED ON THE PLATE OF THE
SCALE BECAUSE WITH THE TIME IT COULD DAMAGE THE LOAD CELL.
• DO NOT USE A FLOW OF WATER TO CLEAN YOUR SCALE. USE A DAMP RAG AND
CLEAN EACH OF THIS COMPONENTS DAILY: PLATE, KEYBOARD.
• TO REMOVE OIL AND GREASY SUBSTANCES, USE A DRY AND CLEAN RAG,
RUBBING THE DIRTY AREA SEVERAL TIMES.
• DO NOT USE DETERGENTS NOR CORROSIVE LIQUIDS WHILE CLEANING.
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE SOLUTION
IT DOES NOT
OPERATE
LOW BATTERY CONNECT THE AC/DC POWER SUPPLY IF
THE SCALE
SHOWS
DIFFERENT
4
5
7
6
WEIGHTS WHEN
THE SAME
PRODUCT IS
WEIGHED
SEVERAL TIMES.
ELECTRIC CURRENT
AC/DC POWER
SUPPLY CABLE HAS
A FALSE CONTACT.
MATERIAL UNDER
THE PLATE HO
THE CORRECT
MOVEMENT
WITH A MULTIMETER, CHECK IF THERE IS
ELECTRIC CURRENT IN THE OUTLETS.
TERMINALS, IF IT IS POSSIBLE, CHECK
WITH ANOTHER AC/DC POWER SUPPLY.
THE SCALE OPERATES, THEN REPLACE
THE BATTERY
CHECK THAT THERE ARE NOT MATERIALS
UNDER THE PLATE HOLDER. IF THERE
ARE, REMOVE THEM AND CHECK THE
OPERATION AGAIN
Page 3
BUT IF YOU PRESS THE
THE COMPARTMENT FOR THE 9 VOLT BATTERY IS LOCATED UNDER THE SCALE. TO
YOU WILL SEE THE FOLLOWING IN THE VIEW FINDER
POWER OFF TIMER FUNCTION .
THIS FUNCTION IS PERMANENTLY ACTIVE WHEN THE SCALE IS WORKING WITHOUT
THE AC/DC POWER SUPPLY CONNECTED INTO THE SCALE. IF THE SCALE IS NOT
USED FOR A PERIOD OF TIME APPROXIMATE TO 15 MINUTES, IT WILL
AUTOMATICALLY TURN OFF. TO TURN ON THE SCALE AGAIN, JUST PRESS THE
KEY.
THE POWER OFF TIMER FUNCTION ALLOW YOU TO SAVE ELECTRICITY AVOIDING A
QUICK BATTERY DISCHARGE.
BATTERY LIFE
THE PS-5 SCALE CAN BE CONTINUOUSLY USED FOR A PERIOD OF TIME OF 48
HOURS USING AN ALKALINE 9 VOLT BATTERY.
.
"LOW BATTERY" INDICATOR
WHEN THE DISPLAY SHOWS THE LOW BATTERY INDICATOR, THE BATTERY IS
ALMOST OUT OF ENER GY. WHEN THIS HAPPENS IT IS PREFERABLE TO REPLACE
THE 9 VOLT BATTERY.
EVEN WITH THIS SIGNAL, IT IS POSSIBLE FOR THE SCALE TO KEEP ON OPERATING
FOR A SHORT PERIOD OF TIME APROXIMATELY (2 HOURS), BUT AFTER A SECOND
WARNING SIGNAL APPEARS ("LOW bAt") IN THE VIEW FINDER, THE SCALE STOPS
ITSELF AND SHUTS ITSELF DOWN.
kg
KEY THE SCALE WILL CHANGE TO “Kg” MODE AND
ON
3.- PLATE HOLDER: MANUFACTURED IN ALUMINUM THAT PROVIDES
SUPPORT
4.- BATTERY COMPARTMENT: PLACE WHERE IS LOCATED THE 9 VOLT
BATTERY (NO INCLUDED)
5.- JACK: CONNECTS THE AC/DC POWER SUPPLY TO THE SCALE WHICH IS
LOCATED IN THE BOTTOM OF THE SCALE (IN THE BASE).
6.- GENERAL VIEW FINDER: IT SHOWS THE WEIGHT OF THE PRODUCTS IN
KILOGRAMS, POUNDS OR OUNCES. THE DISPLAY IS LIQUID CRYSTAL.
7.- MEMBRANE KEYBOARD: WITH BIG MEMBRANE AND READABLE KEYS. IT
IS VERY EASY TO HANDLE.
.
8.- AC/DC ADAPTOR: IT CHANGES FROM 120 VOLTS AC TO 9 VOLTS DC.
THE PLUG OF THIS ADAPTOR IS CONNECTED TO THE JACK.
INSTALLATION INSTRUCTIONS
1.- UNPACK YOUR SCALE AND CHECK THAT YOUR SCALE IS IN GOOD CONDITION IF
THERE IS ANY PROBLEM PLEASE IMMEDIATELY REPORT IT TO THE AUTHORIZED
DITRIBUTOR.
2.- PLACE THE SCALE WHERE THERE IS NOT ANY MOVEMENT OR VIBRATION. MAKE
SURE THE SURFACE IS LEVELED ,
3.- CONNECT THE AC/DC POWER SUPPLY'S CABLE (IF YOU USE IT) TO 120 V a.c.
OUTLET.
4.- TURN THE SCALE ON AND AFTER THE COUNTDOWN SEQUEN CE. YOUR SCALE
WILL DISPLAY ZEROS AND WILL BE READY TO USE.
LOCATION OF THE 9 VOLT BATTERY.
OPEN IT JUST PRESS FROM THE SMALL NOTCH (1) TO THE BIG ONE (2), THEN LIFT
THE CAP. IN ORDER TO HAVE LONG PERIOD OF OPERATION TIME IT IS PREFERABLE
TO USE ALKALINE BATTERY TYPE.
TO ELIMINATE ANY OF THE TWO INDICATORS AND CONTINUE USING THE SCALE,
CONNECT THE AC/DC POWER SUPPLY TO THE SCALE OR REPLACE THE BATTERY.
BASE
Page 4
OPERATION
HOW TO WEIGHT A PRODUCT
TURN YOUR SCALE ON PRESSING THE
COUNTDOWN SEQUENCE STARTS IN THE GENER AL VIEW FINDER. AT THE END OF
THIS COUNTDOWN SEQUENCE, THE VIEW FINDER WILL BE IN "ZEROS" . AT THIS
MOMENT THE SCALE IS READY TO WEIGHT.
THEN PLACE THE PRODUCT TO WEIGHT ON THE PLATE AND YOU WILL SEE THE
WEIGHT IN THE ALPHANUMERIC INDICATOR. THE "Kg", "Lb " OR “Oz” SYMBOL WILL
APPEAR IN THE INDICATOR. FOR EXAMPLE, IF YOU PLACE A PRODUCT WHOSE
WEIGHT IS 2.5 POUNDS, YOU WILL SEE THE FOLLOWING:
HOW TO USE THE “TARE”.
WHEN YOU WISH TO WEIGHT A PRODUCT IN A CONTAINER AND YOU DO NOT WANT
TO CONSIDER THE CONTAINER'S WEIGHT DURING THE OPERATION, YOU CAN USE
THE “TARE” FUNCTION. TO USE THIS FUNCTION, FOLLOW THESE STEPS: SUPPOSE
YOU ARE GOING TO WEIGHT 5 POUNDS OF SOME PRODUCT IN A CONTAINER THAT
WEIGHT 4.5 POUNDS.
PLACE THE EMPTY CONTAINER ON THE SCALE.
PRESS THE
PUT THE PRODUCT INSIDE THE CONTAINER AND THE SCALE SHOWS ONLY THE
WEIGHT OF THE PRODUCT WITHOUT THE CONTAINER'S WEIGHT. NOTICE THAT
WHEN YOU REMOVE THE CONTAINER A NEGATIVE NUMBER (WEIGHT OF
CONTAINER) APPEARS IN THE GENERAL VIEW FINDER.
IT IS IMPORTANT TO MENTION THAT THIS FUNCTION IS SUBTRACTIVE. FOR
EXAMPLE, IF WE HAVE A CONTAINER THAT WEIGHT 4 POUNDS, THE SCALE WILL
ONLY BE ABLE TO WEIGHT UP TO 6 POUNDS OF PRODUCT TO COMPLETE THE
MAXIMUM CAPACITY ( 10 POUNDS, 5 KILOGRAMS OR 160 OZ. IN A PS-5 MODEL).
TARE
KEY. THE VIEW FINDER WILL DISPLAY:
ON
KEY. YOU WILL SEE THAT A
TO CANCEL THE TARE FUNCTION JUST PRESS THE
RETURN TO THE NORMAL FUNCTION. THE NET SYMBOL WILL DISAPPEAR
NOTE: MAKE SURE THAT THE SCALE IS FREE OF WEIGHT OVER THE PLATE
THE TWO FOLLOWING OBSERVATIONS ARE SPECIALLY IMPORTANT.
A) WHEN THERE IS NO WEIGHT ON THE SCALE YOU CAN NOT ACTIVATE THE
"TARE" FUNCTION.
B) WHEN A CONTAINER IS "TARED", BUT WHEN YOU REMOVE IT FROM THE PLATE
AND YOU REMOVE A LARGER WEIGHT THAN THE CONTAINER, (GREASE, REMAINING
OF A PRODUCT, ETC.), OR WHEN THE PLATE IS SLIGHTLY LIFTED WITH YOUR HAND.
"NEG" (NEGATIVE) WILL APPEAR.
HOW TO USE THE "REFERENCE TO ZERO"
IT IS POSSIBLE FOR THE SCALE TO SHOW A NUMBER IN THE VIEW FINDER
WITHOUT HAVING ANY PRODUCT ON THE PLATE DUE TO VOLTAGE VARIATIONS,
ROUGH HANDLING, OR SOME OTHER FACTOR. WHEN THIS HAPPENS, SIMPLY PRESS
ZERO
THE
WILL APPEAR IN THE VIEW FINDER. THIS OPERATION IS COMMONLY KNOWN AS
"RESETTING TO ZERO".
HOW TO USE THE
IF THE SCALE IS IN THE “Lb” MODE AND YOU PUT ON THE SCALE A PRODUCT THAT
WEIGHTS 5 POUNDS YOU WILL SEE THE FOLLOWING IN THE VIEW FINDER
IF YOU PRESS THE
WILL SEE THE FOLLOWING IN THE VIEW FINDER
KEY AND THE VIEW FINDER WILL RETURN TO "ZERO". THE WORD "ZERO"
kg, lb
oz
oz
,
KEYS .
KEY THE SCALE WILL CHANGE TO “oz” MODE AND YOU
TARE
KEY AND THE SCALE WILL
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.