Toro 51574 - Rake & Vac 10.5 Amp Electric Blower/Vacuum, 51574, 51602, 51609, Rake and Vac 51574 Operator's Manual

...
FormNo.3370-936 Rev A
RakeandVac™,Super,andUltraBlower/Vacuum
ModelNo.51574—SerialNo.312000001andUp ModelNo.51602—SerialNo.312000001andUp ModelNo.51609—SerialNo.312000001andUp
Operator'sManual
Registeratwww.Toro.com.
Ifyouhavequestionsorproblems,calltollfree 1-888-367-6631(US),1-888-430-1687(Canada),or 1-800-574-3312(Mexico)beforereturningthisproduct.
IMPORTANTSAFETY INSTRUCTIONS
Whenusinganelectricalappliance,basicprecautionsshould alwaysbefollowed,includingthefollowing:
READALLINSTRUCTIONS BEFOREUSINGVAC/BLOWER
WARNING—Toreducetheriskofre,electric
shock,orinjury,followthesesafetyinstructions.
Toensuremaximumsafety,bestperformance,andtogain knowledgeoftheappliance,itisessentialthatyouoranyother operatoroftheappliancereadandunderstandthecontentsofthis manualbeforeoperatingtheappliance.Payparticularattentionto thesafetyalertsymbol
whichmeansCAUTION,WARNINGor
DANGER-personalsafetyinstruction.Readandunderstandthe instructionbecauseithastodowithsafety.Failuretocomply
withtheseinstructionsmayresultinpersonalinjury,riskof re,orelectricalshock.
Donotleavetheappliancewhenpluggedin.Unplugfromoutlet whennotinuseandbeforeservicing.
WARNING-T oreducetheriskofelectricshock,donotusethe applianceonwetsurfaces.Donotexposeittorain.Storeit indoors.
Donotallowappliancetobeusedasatoy .Donotusenear children.Donotletchildrenusetheappliance.
Useonlyasdescribedinthismanual.Useonlymanufacturer's recommendedattachments.
Dressproperly .Keephair,looseclothing,ngers,andallpartsof thebodyawayfromopeningsandmovingparts.Beawareofthe positionoftheblowerandtheairinletsduringoperation.Loose clothing,jewelryandhaircanbedrawnintotheinlets(refertothe followinggure)andmayresultinpersonalinjury.Alwayswear substantialfootwear,longpants,andeyeprotection.
G017088
Caution—MovingParts—donotoperatetheappliancewithout theairinletguardinplace.RefertoSetupforproperassembly instructions.
Donotusewithdamagedcordorplug.Ifapplianceisnotworking asitshould,hasbeendropped,damaged,leftoutdoors,or droppedintowater,returnittoaservicedealer.
Donotpullorcarrybycord,usecordasahandle,closeadoor oncord,orpullcordaroundsharpedgesorcorners.Keepcord awayfromheatedsurfaces.
Donotunplugbypullingoncord.Tounplug,grasptheplug,not thecord.
Donothandleplugorappliancewithwethands.
Donotputanyobjectintoopenings.Donotusewithanyopening blocked;keepfreeofdust,lint,hair,andanythingthatmayreduce airow.
Turnoffallcontrolsbeforeunplugging.
Useextracarewhencleaningonstairs.
Donotusetovacuumupammableorcombustibleliquids,such asgasoline,oruseinareaswheretheymaybepresent.
Thisapplianceisprovidedwithdoubleinsulation.Useonly identicalreplacementparts.Seeinstructionsforservicingof Double-InsulatedAppliances.
Donotvacuumanythingthatisburningorsmoking,suchas cigarettes,matches,orhotashes.
Donotusewithoutvacbagorproperattachmentsinplace.
SAVETHESE INSTRUCTIONS
©2012—TheToro®Company 8111LyndaleAvenueSouth Bloomington,MN55420
Registeratwww.T oro.com.
OriginalInstructions(EN)
PrintedintheUSA
AllRightsReserved
SafetyandInstructionalDecals
Important:Safetyandinstructiondecalsarelocatednearareasofpotentialdanger.Replacedamagedorlostdecals.
108-8987
Setup
Registeryourproductatwww.Toro.comtoensurethatTorocan notifyyouinthecaseofasafetyorwarrantyproductrecall.
AssemblingtheBlower
Important:Theblowerwillnotrununlessthebottominlet coverislockedinplace.
1
2
3
G017089
4
ConvertingfromBlowerto Vacuum
WARNING
Theimpellerrotatesforafewsecondsafteryouturn offtheblowerandcancutorinjurengers.
Donotremovethebottominletcoverwhenthemotoris runningorwhentheunitispluggedintoapoweroutlet.
1.Removetheinletcoverandtheblowertube.
1
2
3
G017090
2.Installthevacuumtubeandbag.
Important:Thevacuumwillnotrununlessthevacuum tubeislockedinplace.
1 2
3
G017091
4
2
3.Adjustthestrapasneededforcomfortableoperation.
ConvertingfromVacuumto Blower
1.Removethevacuumbagandthevacuumtube.
1
2
3
G017093
4
2.Installtheblowertubeandinletcover.
Important:Theblowerwillnotrununlessthebottom inletcoverislockedinplace.
1
2
3
G017089
4
Operation
Important:Thisblowerisintendedforoutdoor,residential useonly.Donotuseitindoorsorforcommercialorindustrial purposes.Thisapplianceisforhouseholduseonly.
ConnectingtoaPowerSource
Toreducetheriskofelectricshock,thisappliancehasapolarized plug(i.e.,onebladeiswiderthantheother).Useonlyapolarized, ULlisted(CSAcertiedinCanada)extensioncordrecommended foroutdooruse.Apolarizedplugwilltinapolarizedcordonly oneway.Iftheplugdoesnottfullyinthecord,reversethecord. Ifitstilldoesnott,purchaseapolarizedextensioncord.Ifyou haveapolarizedextensioncordandtheextensioncordplugdoes nottfullyintothewallreceptacle,reversetheplug.Ifitstilldoes nott,contactaqualiedelectriciantoinstalltheproperoutlet.Do notchangetheapplianceorextensioncordpluginanyway.
Useonlyanextensioncordrecommendedforoutdooruse.
WARNING
Ifyoudonotfullyseattheextensioncordonthe inletplug,oriftheplugandcorddonottrmly,the looseplugcouldleadtooverheatingandcauseare, possiblyburningyouorothers.
Ensurethatyoufullyseatthecordontheplug.
Checktheconnectionregularlytoensurethatthe
cordisrmlyattached.
Donotuseaworn-outorlooseextensioncord.
ExtensionCordLengthMinimumWireGage(A.W.G.)
100ft
14
150ft
12
Note:Donotuseanextensioncordover150feet.
Important:Checktheextensioncordfrequentlyduringuse forholesintheinsulation.Donotuseadamagedcord.Do notrunthecordthroughstandingwaterorwetgrass.
Securetheextensioncordtotheblowercordusingan overhandknot,asshown.
3
Starting/Stopping/Adjusting theAirSpeed
G017095
UsingtheNozzles
Installthepower(UltraandSupermodelsonly)andconcentrator nozzlesintotheblowertubetohelpreachintonarrowspacesor toremovematteddebrisfromhardsurfaces.OnUltraandSuper blowersyoucanusethepowernozzlewithouttheconcentrator formorepowerwhenblowing.
1
2
3
4
G017266
1.Blowertube
3.Concentratornozzle
2.PowerNozzle(Ultraand SuperBlowersonly)
4.Cordwrap(UltraBlower only;refertoUsingthe CordWrap)
UsingtheBlower
Theblowerisintendedforresidentialuseonly.Usetheblower outdoorstomovedebrisasneeded.
WARNING
Theblowercanthrowdebris,possiblycausingserious personalinjurytotheoperatororbystanders.
Donotblowhardobjectssuchasnails,bolts,or
rocks.
Donotoperatetheblowernearbystandersorpets.
Useextracarewhencleaningdebrisfromstairsor
othertightareas.
Wearsafetygogglesorothersuitableeye
protection,longpants,andshoes.
UsingtheVacuum
WARNING
Thevacuumcanthrowdebris,possiblycausing seriouspersonalinjurytotheoperatororbystanders.
Donotoperatethevacuumwithoutthebaginstalled
orwiththebagzipperopen.
Donotvacuumsharp,pointed,orhardobjectsthat
couldbethrownthroughthefabricofthebag,such aswires,staples,nails,orrocks.
G017098
Important:Vacuumonlyleavesandsoftitems.Harditems suchassticks,rocks,acorns,andpineconeswilldamage theimpeller.
Important:Donotforcethevacuumtubeintoapileofdebris orholdthetubeuprightwhileforcefeedingdebrisintothe tube.Eitheractionmaycloganddamagetheimpeller.Ifthe vacuumstartstovibrateormakeabnormalnoise,stopit, unplugthecord,andcheckforthecause.
EmptyingtheBag
1.Turnoffandunplugthevacuumfromthepowersource.
2.Emptyanydebrisfromthebag.
G017099
4
Donotstoredebrisinthebag.T ocleanthebag,turnit insideoutandshakeoutanyexcessdebris.Onceayear, handwashthebaginsoapywaterandallowittoairdry.
DANGER
Normalusageofthebagcausesittowearand deteriorateovertime.Awornordeterioratedbag allowssmallobjectstobethrownthroughthebag, possiblyinjuringtheoperatororbystanders.
Checkthebagfrequently.Ifitiswornor deteriorated,replaceitwithagenuineToro vacuumbag.
SeparatingtheVacuumTube
Models51574and51602only
1
2
G017094
RemovingCloggedDebris fromtheImpeller
1.Turnoffandunplugthevacuumfromthepowersourceand
waitforallmovingpartstostop.
2.Removethevacuumtubethenremovethedebrisfrom impellerblades.
1 2
3
G017100
3.Checktheimpellerforanysignsofdamage.Ifitisdamaged, contactyourAuthorizedT oroDealer.
4.Installthevacuumtube,or,ifyouwanttoswitchtoblower mode,thebottominletcover.RefertoConvertingfrom BlowertoV acuumorConvertingfromVacuumtoBlower formoreinformation.
Service
Torohasdesignedthisproducttogiveyouyearsoftroublefree use.Shoulditneedservice,bringtheproducttoyourAuthorized ToroServiceDealer.YourT oroDealerisspeciallytrainedtorepair ToroproductsandwillensurethatyourT orostays“All”T oro.
Double-insulatedAppliances
Inadouble-insulatedappliance,twosystemsofinsulation areprovidedinsteadofgrounding.Nogroundingmeansis providedonadouble-insulatedappliance,norshouldameansfor groundingbeaddedtotheappliance.Servicingadouble-insulated appliancerequiresextremecareandknowledgeofthesystem, andshouldbedoneonlybythequaliedservicepersonnelat yourAuthorizedT oroServiceDealer.Replacementpartsfora double-insulatedappliancemustbeidenticaltothepartsthey replace.Adouble-insulatedapplianceismarkedwiththewords “DoubleInsulation”or“DoubleInsulated.”Thesymbol(square
withinasquare)
mayalsobemarkedontheappliance.
Storage
Storetheblower/vacuumandextensioncordindoors,inacooldry location,outofreachofchildrenandanimals.
UsingtheCordWrap
Model51609only
InstallthecordwrapasillustratedinUsingtheNozzles(page4). Wrapyourextensioncord(cordnotprovided)aroundtheblower, asshown,foreaseofstorage.
Important:Alwaysunplugtheblowerbeforewrappingthe cordorstoringit.
G017267
Troubleshooting
Ifyourblowerfailstorunwhenyouturniton,checkthefollowing beforecontactingyourAuthorizedT oroServiceDealer:
Ensurethatthebottominletcoverorvacuumtubeislockedin
place.
Ensurethatthepowercordissecuredinplaceonthebackof
theblowerandthattheplugisfullyseated.
5
Loading...