Toro TMC-424E Series Scheduling Form

Calendar Days S M T W T F S
Interval Odd/Even Excluded Days
S M T W T F S
Pump Enable
Pump Delay
Cycle Repeat
Start Times
1 9 1 9 1 9 1 9
2 10 2 10 2 10 2 10
3 11 3 11 3 11 3 11
4 12 4 12 4 12 4 12
5 13 5 13 5 13 5 13
6 14 6 14 6 14 6 14
7 15 7 15 7 15 7 15
8 16 8 16 8 16 8 16
Module I
Run Learned Run Learned Run Learned Run Learned
Station Location Time Flow Time Flow Time Flow Time Flow
__
(1)
__
(2)
__
(3)
__
(4)
__
(5)
__
(6)
__
(7)
__
(8)
Module II
Run Learned Run Learned Run Learned Run Learned
Station Location Time Flow Time Flow Time Flow Time Flow
__
(1)
__
(2)
__
(3)
__
(4)
__
(5)
__
(6)
__
(7)
__
(8)
Module III
Run Learned Run Learned Run Learned Run Learned
Station Location Time Flow Time Flow Time Flow Time Flow
__
(1)
__
(2)
__
(3)
__
(4)
__
(5)
__
(6)
__
(7)
__
(8)
S M T W T F S S M T W T F S S M T W T F S
Program
A B C D
S M T W T F SS M T W T F SS M T W T F S
(Maximum 16 start times, all programs combined.)
TMC-424E Watering Schedule Form
© 2008 The Toro Company • Irrigation Division www.toro.com • Form Number 373-0470 Rev. A
V0071 Software version (example shown) SEC-Y Station time in seconds increments 12 H or 24 H 12- or 24-hour clock format
NFLOW Nominal flow threshold exceeded FLOW Flow monitor threshold exceeded Display Alert FUSE (01–16) Overload condition exists on (station) % Season Adjust not (100%)
Run SEN Rain sensor activated 01–14 Rain delay active, 01–14 days off OFF OFF No controller operation
•Flow monitor settings
•Rain sensor assignment per program
•Station run times
•Start time(s)
•Day schedule type
•Total station time duration per program Review •Total program duration (all factors)
(30 seconds to 9 minutes)
Manual station operation
Valve Test 2M Test run time for each station Manual Station (01–16)
Manual Program MAN Semi-automatic program operation
for each flow-monitored station LF Learned Flow - Standard flow rate
(terminates operation) CF Flow rate above learned flow
UF Flow rate under learned flow OF Flow rate over learned flow FLO - Y/N Flow monitor operation by station NF Nominal Flow - Flow threshold when off MV:NC/NO Master Valve: Normally Open or Closed FIL:01 Fill delay option, Off–9 minutes RS[A] - Y Rain Senor control by program Sensors TBP-N Rain Sensor Timed Bypass, Yes/No
or POR-Portuguese FRA-French, ITA-Italian, DUE-German
ENG Language: ENG-English, ESP-Spanish, 1PROG Program Stacking/Overlap, 1–3 DL - - (if CYC-Y) Delay between repeat cycles RPT - - (if CYC -Y) Repeat cycles, Off–30 CYC-N Program watering cycle repeat - Off during a station delay period
PE Pump Enable - Enable pump operation after pump start, Off–60 seconds
PD Pump Delay - delay station start MVS-N Master valve (excluded) by station MV[A]-Y Master valve active by program 01–60M (minutes)
Special Functions SD Station Delay, Off–60 seconds or Season Adjust Increase or decrease by 10%
Excluded day Active watering day SUN–SAT Day exclusion Day Current day within the interval cycle Day Interval 01 DAY Watering day frequency
Excluded day Active watering day SUN–SAT Day exclusion
Odd/Even Odd or Even Odd or Even number day schedule Calendar Days SUN–SAT Watering schedule by calendar days
Station Times SEC Runtime in seconds
Day of Week (3-letter abbreviation) Day (in numeric value)
Current Time/Day Time, Year, Month,
Dial Position Symbol Description Dial Position Symbol Description
Loading...