254/264 Series
Plastic Valves
VALVES
Extremely rugged residential/commercial valves designed for reliable
performance.
20 and 25mm (3⁄4
" and 1") Electric Models
Features
• Male-threaded inlet and male-threaded or barbed outlet available
• Barbed insert models for use with poly pipe
• Manual flow control: adjustable to zero flow (254 Series)
• Manual bleed screw
• Energy-efficient solenoid
• 45cm (18") lead wires for easy-access installation
• Self-cleaning, stainless-steel metering pin (electric models)
• Stainless-steel diaphragm differential spring for smooth, positive
closing
• Single-piece rubber diaphragm for reliable, leak-free valve closing
•Tough, glass-filled Zytel
®
cap and body provides stability under
pressure
• Zytel Super Tough and stainless-steel construction for exceptional
durability
•Available with or without flow control
Specifications
25mm (1") Models
• Recommended flow range: 19-170 LPM (5-45 GPM)
• Operating pressure: 1.4-10 Bar (20-150 PSI)
• Burst pressure safety rating: 52 Bar (750 PSI)
• Body styles: Globe valve
• 2X4-06: 25mm (1") male-threaded inlet and outlet
• 2X4-16: 25mm (1") male-threaded inlet, 25mm (1") insert
(barbed) outlet
• Solenoid: 50/60 Hz (24 V.a.c.)
• Inrush: 0.30 Amps, 7.20 VA
• Holding: 0.20 Amps, 4.80 VA
• Dimensions:
• 254 Series (with flow control):
152 x 115mm (H x W) (6" x 41⁄2
") (H x W)
• 264 Series (without flow control):
115 x 115mm (H x W) (41⁄2
" x 41⁄2
") (H x W)
20mm (3⁄4") Models
• Recommended flow range: 2-57 LPM (0.5-15.0 GPM)
• Operating pressure: 1-10 Bar (15-150 PSI)
• Burst pressure safety rating: 52 Bar (750 PSI)
• Body style: Globe valve
• 20mm (3⁄4
") male-threaded inlet and outlet
• Solenoid: 50/60 Hz (24 V.a.c.)
• Inrush: 0.25 Amps, 6.00 VA
• Holding: 0.19 Amps, 4.50 VA
• Dimensions:
76 x 102mm (H x W) (3" x 4" H x W)
Effluent flow-control
knob available
(Part No. 89-7855)
Manual bleed screw
Optional
flow control
Tough, glass-
filled Zytel cap
and body
Single-piece rubber
diaphragm
Stainless-steel
metering pin
254 Male x Male Valve
254 / 264 Series Friction Loss Chart – English Data (PSI)
Flow (GPM) 0.5 1 3 5 10 15 20 2 5 30
3
⁄4
" Electric <1.0 <1.0 <1.0 1.5 3.0 6.5
1" Electric 2.0 2.0 2.3 3.1 4.0 5.4
254 / 264 Series Friction Loss Chart – Metric Data (Bar)*
Flow (LPM) 2 25 50 75 100 125
20mm (
3
⁄4") Electric <0,1 0,1 0,4 0,7
25mm (1") Electric 0,1 0,2 0,2 0,3 0,4
Flow Control Body Threads Size
Specifying Information
2X4 X6 0X
5–w/ F.C.
6–w/o F.C.
0–Male Thread x Male Thread-NPT
1–Male Thread x Barb-NPT
3–20mm (
3
⁄4")
4–25mm (1")
For Example:
When specifying a 25mm (1") electric 264 Series valve
without flow control and with a male thread x 25mm (1") insert,
you would specify:
264-16-04
264-06-03
254-16-04
264-06-04
254-06-04
264-16-04
20mm (3⁄4") available with male x male thread without flow control only.
Note: For optimum sprinkler performance when designing a system,
calculate total friction loss to ensure sufficient downstream pressure.
Flow rates are recommended not to exceed 5 PSI loss.
*Values are listed in Bar. For kPa values, multiply tabular values by
100. For Kg/cm
2
values, multiply tabular values by 1,02. Flow rates
are recommended not to exceed 0,35 Bar loss