600 series hydraulic valves are configured with an in-line filter, three-position selector and a three-way pilot for downstream pressure reducing or pressure sustaining/relief.
• Three-way pressure-sensing pilot controls hydraulically operated valves
• The pilot vents to atmosphere for pressure regulation, giving the advantage of fully opening the main valve when conditions call for minimum pressure loss
• The pilot is versatile – by changing the porting, the same pilot valve can be used to convert a hydraulic valve into a pressure reducing or pressure sustaining/relief control valve
• Downstream pressure regulating range from 5 psi to 113 psi
Three-position selector
• This valve allows for selection of hydraulic control modes: open, closed or automatic
• Allows for manual override for opening or closing the main control valve
Flow control stem
• Flow control allows for precise flow adjustment
600 Series Valves
Additional Features:
• Self-cleaning In-line filter for filtration of the command system water
• Non-continuous metering system – since only a small exchange of control water is used to operate the main valve, the system is less susceptible to failure due to plugging
• Available in 2" and 3" (51 and 76mm)
• Working pressure is 10 to 150 psi (.7 to 10.3 bar)
• Flow range from 80 gpm to 300 gpm (5.0 to 18.9 l/s)
• Manual external bleed
• Glass reinforced nylon body and bonnet give superior high temperature strength
Understanding 600 Series Valves Part Numbers
Example: 601 –3–T– 01 –B
Valve Category
asic Hydraulic –600
B
ressure Reducing –601
P
ressure Sustaining/Relief –602
P
ressure Reducing and –603
P
ustaining/Relief Valve
S
Valve Size
wo-inch Valve –2
T Three-inch Valve –3
Options
Three Position Selector Valve –T
Electric Control
o Solenoid –00
N Solenoid 24 VAC –01 24 VDC Latching –02 9 – 12 VDC Latching –03
Pilot Springs
5–20psi Blue –B 9–35psi Green –G 21–113psi Silver –S
Pressure Loss in PSI
Flow Rate (GPM)
Style Size 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 175 200 225 250 275 300
Globe Angle 1.2 1.6 2.0 2.4 2.8 3.3 3.9 4.4
Globe Angle 1.9 2.4 3.3 4.3 5.5 6.9 8.5
2"
3"
2.1 2.7 3.3 4.0 4.8 5.6 6.5 7.5
2.5 3.0 4.1 5.3 6.7 8.3 10.1
Pressure Loss in Bar
Flow Rate
Liters/second 0,5 1,0 1,5 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 11,0 12,0 13,0 14,0 15,0 16,0 17,0 18,0 19,0
M3/Hour 1,8 3,6 5,4 7,2 10,8 14,4 18,0 21,6 25,2 28,8 32,4 36,0 39,6 43,2 46,8 50,4 54,0 57,6 61,2 64,8 68,4
Style Size
Globe
50mm
Angle 0,08 0,12 0,17 0,22 0,28
Globe
75mm
Angle 0,14 0,16 0,20 0,24 0,29 0,34 0,39 0,45 0,52 0,59
NOTES: (1) When designing a system, the industry standard for flow rate velocity through pipes and fittings is 5 Fps (2m/s).
(2) Pressure loss data is derived from valves independently tested by C.I.T., Fresno, CA. (3) Hydraulic actuated valves vented to atmosphere will show lower pressure loss figures at low flows. (4) Pressure regulating valves must operate in the recommended flow ranges – For the best pressure regulation the
valves should be sized at the upper end of the flow range.
0,14 0,21 0,28 0,37 0,47
0,18 0,21 0,25 0,30 0,35 0,41 0,48 0,54 0,62 0,70
©2012 The Toro Company Micro-Irrigation Business
1588 N. Marshall Avenue, El Cajon, CA 92020-1523, USA Tel: +1(800) 333-8125 or +1 (619) 562-2950 Fax: +1 (800) 892-1822 or +1 (619) 258-9973
toro.com
ALT057 1/04