Multi Pro® 5800
Initial Console Programming
The console will require programming upon initial setup or any time the controller system values must be reset
to their default settings. When turning the console power on for the first time, the console will flash “CAL” in
the RATE display. This indicates that the console must be programmed before it can be operated. Once the
console is programmed, the “CAL” indicator will stop flashing and the values will be stored in memory.
Turning the power ON/OFF switch to the “OFF” position will not affect the stored values.
FOLLOW THESE STEPS:
Note: Reset the console system settings by turning power switch to the OFF position, depress
and hold while turning the power switch ON
If an entry selection is made in error during steps 1 & 2, simply reset the Console.
CE
STEP 1: Selecting US (Acres), SI (Hectares) or TU (1,000 sq. ft.)
A. Momentarily depress until you reach the desired setting. (US, SI or TU)
B. Once the desired setting has been reached, momentarily depress
to lock in your selection.
CE
ENTER
STEP 2: Program Keys
Program keys 1-8 (top row of the Console) using the key reference on the reverse side.
DATA ENTRY KEYSTROKE SEQUENCE:
1. Depress the key in which you wish to enter data (i.e. “BOOM 1 CAL”, “SPEED CAL”, etc.) and then Depress .
2. Depress the keys corresponding to the number you wish to enter (i.e. “2”, “4”, etc.) and then Depress to complete the entry.
*Numbers listed are default system values. Before spraying, calibrate your sprayer to confirm the numbers used are correct. Consult the Pro Control XP Operator’s Manual for full details on Set-Up and Operation.
BOOM 1
Clear entry – Will clear a
wrong entry. Also used
in Initial Programming to
toggle between settings.
CE
1
CAL
* Use 80” [203 cm]
Number of nozzles
x spacing in inches [cm]
of left boom.
Totals area covered in
acres, 1000 sq. ft. or ltr/ha
until cleared to zero.
Monitors volume applied
in gallons or liters until
cleared to zero.
Totals area covered in
acres, 1000 sq. ft. or ltr/ha
until cleared to zero.
Monitors volume applied
in gallons or liters until
cleared to zero.
Measures distance in
feet or meters until
cleared to zero.
Displays speed in MPH
or km/h.
TOTAL
AREA
VOLUME
TOTAL
FIELD
AREA
VOLUME
FIELD
DISTANCE SPEED ENTER
2
3
4
5
6
7
BOOM 2
CAL
BOOM 3
CAL
SPEED
CAL
METER
CAL
VALVE
CAL
RATE 1
CAL
* Use 60” [152 cm]
Number of nozzles
x spacing in inches [cm]
of center boom.
* Use 80” [203 cm]
Number of nozzles
x spacing in inches [cm]
of right boom.
*
Use 148 [38] w/Half Full
Tank. Reset Distance readout
to “0”. Drive vehicle 500 ft.
Verify distance readout is
490-510 ft. [150 m]
Use number on silver tag
on the Flow Meter’s cable.
* Use 23 (for 0.5 GPM &
higher nozzles).
Use 46 (for 0.2 & 0.4
GPM nozzles).
Sets system response.
First rate of application
in Gal/Acre. Gal/1000 sq.
ft., or lit/ha depending on
initial set up.
Multi Pro
5800 Pro Control
XP Key Reference
®
TM
ENTER
ENTER
11-082-T Part No. 120-8599
Displays gallons or liters
per minute that system
is currently using.
Displays acres, 1000 sq. ft.
or hectare covered per
hour at speed driven.
Used to adjust Agitation.
(Note: when the number
increases, the agitation
pressure increases.
This number is NOT the
agitation pressure.)
Used for other operations,
See Owner’s Manual.
Used to enter data into
Console.
VOL /
MIN
AREA /
HOUR
MENU
DATA
8
9
0
RATE 2
CAL
TANK
VOL
TIME
TEST
SELF
Second rate. If only one
rate is used, use same
value here that was used
in Rate 1.
Reset volume when filling.
24-Hour Clock (military
time) or Elapsed Timer.
Simulates speed to allow
operator to check system
operation before applying
chemicals while vehicle is
parked. If “SELF TEST” is
depressed and held at any
time, US, TU or SI will flash,
indicating spray area entered during initial setup.