FormNo.3409-678RevB
MultiPro
ModelNo.41188—SerialNo.400000000andUp
®
1750TurfSprayer
SoftwareGuide
Readthisinformationcarefullytolearnhowtooperateandmaintainyourproductproperlyandtoavoidinjury
andproductdamage.Youareresponsibleforoperatingtheproductproperlyandsafely.
Wheneveryouneedservice,genuineT oroparts,oradditionalinformation,contactanAuthorizedServiceDealer
orToroCustomerServiceandhavethemodelandserialnumbersofyourproductready .
YoumaycontactT orodirectlyatwww.Toro.comforproductsafetyandoperationtrainingmaterials,accessory
information,helpndingadealer,ortoregisteryourproduct.
Introduction
Thisguideprovidesinformationforusingsprayer
systeminformationandcontrollingsprayersystem
functions.
Contents
Introduction...............................................................1
Setup........................................................................1
BeforeYouBeginSpraying.................................1
ProductOverview.....................................................2
Controls.............................................................2
Operation..................................................................4
BeforeOperation...................................................4
StartingtheInfoCenter........................................4
InfoCenterMainSubMenus...............................5
CalibratingtheSprayer......................................11
EnteringtheSprayTankVolume........................11
DuringOperation.................................................12
InfoCenterSprayAreaScreens........................12
InfoCenterAdvisories.......................................13
Maintenance...........................................................14
ServiceScreens...............................................14
DiagnosticsScreens.........................................15
AboutScreens..................................................17
Setup
BeforeYouBeginSpraying
PreparingtheMachine
1.Fillthesprayertankandfreshwatertank;refer
tollingthespraytankandllingthefresh-water
tankproceduresintheOperator’sManual.
2.Calibratethemachine;refertotheMultiPro
1750TurfSprayerOperator’sManualfor
informationaboutcalibratingthemachine.
3.Enterthecorrectvolumeofliquidinthespray
tank;refertoEnteringtheSprayT ankVolume
(page1 1)
©2017—TheT oro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA
AllRightsReserved
*3409-678*B

ProductOverview
downmenus.
•Rightselectionbutton—usethisbuttontoopen
•Middleselectionbutton—usethisbuttontoscroll
Controls
amenuwherearightarrowindicatedadditional
content.
InfoCenterHomeScreen
Whenyoustartthemachine,thehomescreen
appears,displayingthecorrespondingiconsthat
apply(i.e.,theparkingbrakeisengaged,thesprayer
sectionsareon,theoperatorisoutoftheseat,etc.).
Note:Thefollowinggureisanexamplescreen;this
screenshowsallofthepotentialiconsthatcould
appearonthescreenwhileoperating.
Refertothefollowinggraphicforalloftheicon
denitions(Figure1).
Note:Thepurposeofeachbuttonmaychange
dependingonwhatisrequiredatthetime.Each
buttonhasanicondisplayingitscurrentfunction.
Master-SectionIndicator
Themaster-sectionindicatordisplayswhenthe
masterboomswitchisintheONposition(Figure1).
Sprayer-SectionIndicators
Theleft,right,and/orcentersprayersectionsdisplay
whenanyofthesprayer-sectionswitchesareinthe
ONposition(Figure1).
Spray-Tank-VolumeIndicator
Thespraytankiconappearswhenaspraytank
volumegreaterthan0isregistered.
Active-ApplicationRate
Theactive-applicationrateindicatestheactualrateat
whichthesprayedproductisbeingapplied(Figure1).
Figure1
1.Rightsection
indicator—ON
2.Applicationrate
3.Parkingbrake(applied)
4.Hillassist(active)10.Throttlelock(active)
5.Spraytankvolume(US
gallonsshown)
6.Rightselectionbutton12.Mastersection-switch
Left,Center,andRightSelectionButtons
7.Centerselectionbutton
8.Leftselectionbutton
9.Vehicle-speedindicator
(mphshown)
11.Speedlock(active)
indicator—ON
Usetheleft,center,andrightselectionbuttonstodo
thefollowing:
•Leftselectionbutton—pressthisbuttontoaccess
theInfoCentermenus.Y oucanalsouseittoexit
anymenuthatyouarecurrentlyusing.
Vehicle-SpeedIndicator
Thevehicle-speedindicatordisplaysthecurrent
vehiclespeed(Figure1).
g202824
Parking-BrakeIndicator
Theparking-brakeindicatordisplaysontheHome
Screenwhentheparkingbrakeisengaged(Figure1).
Hill-AssistIndicator
Thehill-assistindicatordisplaysonthehomescreen
whenthehillassistfunctionisenabled.
SpeedLock
Thespeedlockiconappearswhenspeedlockis
active.
ThrottleLock
Thethrottlelockiconappearswhenthrottlelockis
active.
2

InfoCenterIconDescriptions
IconDescription
Informationicon
Fullspraytank
Spraytankathalf
Next
Previous
Scrolldown
Enter
Changethenextvalueinthe
list
Increase
Decrease
Activescreen
Inactivescreen
Gotothehomescreen
Tanklevellow
Emptyspraytank
TURFunits(1,000ft²)
or
Areasprayed
Volumesprayed
Adjusttankvolume
Homescreen
Clearactivearea
Activehomescreen
Savevalue
Exitmenu
Hourmeter
CorrectPINcodeentered
CheckPINentry/Calibration
verication
Parkingbrakeactive
Hillassist
MasterboomOn/Boom
sprayerOff
MasterboomOn/Boom
sprayerOn
Clearallareas
Adjustdigit
Selectthenextareafor
accumulation
Throttlelockisactive
3

Operation
BeforeOperation
StartingtheInfoCenter
1.Insertthekeyintothestarterswitchandrotateit
totheONposition.
TheInfoCenterilluminatesanddisplaysthe
initializationscreen,whichdisplaysvoltmeter
andhourmeterinformation(Figure2).If
youhavetheGeoLinksystemequipped,the
initializationscreenshowstheGeoLinklogo
insteadoftheT orologo(Figure3).
buttontodisplaytheinformationcontext(Figure
4).
g028528
Figure4
•Pressthecenterselectionbuttonagainto
navigatetothemainmenu.
Fromthemainmenuscreen,youcanaccess
severalsubmenus;refertoInfoCenterMain
SubMenus(page5)
•Usetherightandleftselectionbuttonsto
navigatetotheSprayAreaandtheSpray
TankVolumescreens;refertoInfoCenter
SprayAreaScreens(page12)andEntering
theSprayTankVolume(page11).
1.Voltmeter2.Hourmeter
Figure2
Figure3
Note:MachineswiththeGeoLinksystem
installedandenabledcanonlyaccessthe
g202966
mainmenu.
Note:RotatingthestarterswitchtotheSTART
positionandstartingtheenginecausesthevalues
indicatedintheInfoCenterdisplaytoreectthe
runningmachine.
g202724
1.Voltmeter3.Hourmeter
2.GeoLinklogo
2.Afterapproximately15seconds,thehome
screenwillappear;pressthecenterselection
4

InfoCenterMainSubMenus
UsingtheMenus
ToaccesstheInfoCentermenusystem,pressthe
menuaccessbuttonwhileatthemainscreen.This
willbringyoutothemainmenu.Refertothefollowing
tablesforasynopsisoftheoptionsavailablefrom
themenus:
Calibration
MenuItemDescription
TestSpeedSetsthetestspeedforcalibration.
FlowCalCalibratestheowmeter.
SpeedCalCalibratesthespeedsensor.
UseFlowCal
Default
UseSpeedCal
Default
Settings
MenuItemDescription
HillAssist
SprayT ank
Alert
Units
Language
Backlight
ContrastChangesthecontrastbetweenthedarkand
GeoLinkSatellitenavigationoption
Protected
Menus
Protect
Settings
LBoom
CBoomAdjuststhewidthofthecentersection.
RBoom
ResetDefaultsResetsseveralfunctionstotheirfactory
Resetstheowcalibrationtothedefault
calculatedaverage,nottheactualvolume.
Resetsthespeedcalibrationtothedefault
calculatedaverage,nottheactualspeed.
Enablesordisablesthehillassistfeature.
Setsthelowtankvolumealert.
ChangestheunitsusedbytheInfoCenter.
ThemenuchoicesareEnglish,SI(Metric),
andTurf.
Changesthelanguageusedonthe
InfoCenter.
Increasesordecreasesthebrightnessofthe
LCDdisplay.
lightareasoftheLCDdisplay.
Grantsaccesstoprotectedmenus.
LockstheadjustmentofLBOOM,CBOOM,
andRBOOMwhenenabled.
Adjuststhewidthoftheleftsection.
Adjuststhewidthoftherightsection.
defaults.
Service
MenuItemDescription
Faults
Hours
FlowRate
FlowCalValue
SpeedCal
Value
Displaysthemostrecentfaultsandlast
clearedfault.
Liststhetotalnumberofhoursforkeyon,
machinerun,andpumpon.Italsoliststhe
serviceduehourandservicereset.
Displaysthecurrentowrate.
Displaysthecurrentmultiplierusedto
calculatethedifferencebetweenthe
assumedowandthecalibratedow.
Displaysthecurrentmultiplierusedto
calculatethedifferencebetweenthe
assumedspeedandthecalibratedspeed.
Diagnostics
MenuItemDescription
PumpsAccessesthepumpinputs,momentaryrinse,
Booms
ThrottleLock
EngineRunAccessestheengineruninputsandoutputs.
andtimerinseoptions.
Accessestheboominputs,qualiers,and
outputs.
Accessesthethrottlelockinputs,quantiers,
andoutputs.
About
MenuItemDescription
Model
SerialNumberListstheserialnumberofthemachine.
S/WRevListstherevisionnumberofthemachine
InfoCtrSWRevListstherevisionnumberoftheInfoCenter
CANBusListsthestatusoftheCANBus
Liststhemodelnumberofthemachine.
software.
software.
Note:Ifyouinadvertentlychangethelanguage
orcontrasttoasettingwhereyoucannolonger
understandorviewthedisplay ,contactyour
AuthorizedToroDistributorforassistanceinresetting
thedisplay .
5

Calibration
SettingtheHillAssistFunction
Note:MachineswiththeGeoLinksysteminstalled
andenabledcannotaccesstheCalibrationsubmenu.
ThecalibrationfunctionismaintainedbytheGeoLink
system.
Toaccessthecalibrationsettings,usethemiddle
selectionbuttontonavigatetotheCALIBRATION,then
presstherightbuttontoenterintothecalibration
screen(Figure5).
Figure5
HillassistissettoONbydefault,butyoucanturnitoff
asfollows:
1.ScrolldowntoHILLASSISTandpressthecenter
selectionbuttontoentertheHillAssistsettings
menu(Figure7).
g202827
Figure7
g202807
2.IntheHillAssistsettingsmenu,selectOFF.
Forinformationoncalibration,seetheMultiPro1750
TurfSprayerOperator’sManual.
Settings
Toaccessthesettingsscreen,usethemiddle
selectionbuttontonavigatetoSETTINGS,thenpress
therightselectionbuttontoenterintothesettings
screen(Figure6).
Figure6
g202811
SettingtheSprayTankAlert
1.Pressthecenterselectionbuttontohighlightthe
Alertsetting(Figure8).
Note:The(-)and(+)iconswillappearabove
thecenterandrightselectionbuttons.
g028521
Figure8
2.Presstherightselectionbutton(Figure8).
3.Usethecenterorrightselectionbuttonstoenter
theminimumquantityinthetankwhenthealert
displaysduringsprayeroperation(Figure8).
Note:Holdingthebuttondownincreasesthe
valueofthetankalertby10%.
4.Presstheleftselectionbuttontosaveandreturn
tothemainmenu.
6

ChangingtheUnitsofMeasure
1.Tochangetheunitofmeasure,usethemiddle
selectionbuttontoscrolltotheUNITSoption
Figure9.
2.Presstherightselectionbuttontochangethe
listedunitsofmeasure(Figure9).
•English:mph,gallons,andacre
•Turf:mph,gallons,and1000ft
2
•SI(metric):kph,liter,hectare
Note:ThedisplayswitchesbetweenEnglish
andmetricunits.
(thebuttonbelowthedownarrowiconinthe
display)tomovetheselectedoptiondowntothe
BacklightorContrastsetting(Figure10).
Figure9
1.Listoptions(icon)3.Rightselectionbutton(list
context)
2.Scrolldown(icon)4.Centerselectionbutton
(scrollcontext)
Note:Pressingtheleftselectionbuttonsaves
yourselection.
ChangingtheLanguage
1.Tochangethelanguageusedinthedisplay,
pressingthecenterselectionbutton(thebutton
belowthedownarrowinthedisplay)tomove
theselectedoptiontoLanguage(Figure9).
2.Presstherightselectionbutton(thebutton
belowthelisticoninthedisplay)tohighlightthe
listedlanguageusedinthedisplay(Figure9).
Note:AvailablelanguagesincludeEnglish,
Spanish,French,German,Portuguese,Danish,
Dutch,Finnish,Italian,Norwegian,andSwedish.
AdjustingtheBacklightandContrastLevelsofthe
Display
g028519
g028415
Figure10
Backlightoptionisselected
1.Selectarrow(icon)5.Increasethevalue(icon)
2.Scrolldown(icon)6.Decreasethevalue(icon)
3.Rightselectionbutton
(selectcontext)
4.Centerselectionbutton
(scrollcontext)
7.Rightselectionbutton
(raisevaluecontext)
8.Centerselectionbutton
(lowervaluecontext)
2.Presstherightselectionbuttontodisplaythe
valueadjustmentcontext(Figure10).
Note:Thedisplayshowsa(―)iconoverthe
centerselectionbuttonanda(+)iconoverthe
rightselectionbutton.
AdjustingtheBacklightLevel
1.Toadjustthebacklightorcontrastlevelsof
thedisplay,pressthecenterselectionbutton
3.Usethecenterselectionbuttonandright
selectionbuttontochangethebrightnessor
contrastlevelofthedisplay(Figure10).
7

Note:Asyouchangethebrightnessorcontrast
value,thedisplaychangesthevalueofthe
selectedlevel.
4.Presstheleftselectionbuttontosaveyour
selection(Figure10).
UsingProtectedMenus
Authorizedindividualscanenterthe4digitpersonal
identicationnumber(PIN)torevealthefollowing
servicefunctions:
•FlowRate
•FlowCalibrationRate
•SpeedCalibrationRate
•ClearSystemFaults
•ServiceTimerReset
EnteringthePINintotheInfoCenter
EnteringthePINallowsyoutochangetheaccess
protectsettingsandmaintainthepassword.
Note:ThefactoryenteredPINnumberis1234.
•Pressthecenterselectionbutton(BofFigure
11)toincreasethenumericalvalue(0to9).
•Presstherightselectionbutton(CofFigure
11)tomovethecursortothenextnumerical
positiontotheright.
4.Oncetheright-mostvalueisset,presstheright
selectionbutton.
Note:Thecheckmarkiconappearsabovethe
centerselectionbutton(DofFigure1 1).
5.Pressthecenterselectionbutton(DofFigure
11)toenterthepassword.
ChangingthePIN
1.EnterthecurrentPIN;refertosteps1through5
inEnteringthePINintotheInfoCenter.
2.Pressthecenterselectionbuttontohighlightthe
ProtectedMenussetting.
1.Usethecenterselectionbuttontohighlightthe
ProtectedMenussetting.
Figure11
2.PresstherightselectbuttontoselectProtected
Menus(AofFigure11).
3.SetthenumericalvalueinthePINentryscreen
bypressingthefollowingselectionbuttons:
g028717
Figure12
3.PresstherightselectbuttontoselectProtected
Menus(AofFigure12).
4.EnterthenewPINintotheentryscreenby
pressingthefollowingselectionbuttons:
g028522
•Pressthecenterselectionbutton(BofFigure
12)toincreasethenumericalvalue(0to9).
•Presstherightselectionbutton(CofFigure
12)tomovethecursortothenextnumerical
positiontotheright.
5.Oncetheright-mostvalueisset,presstheright
selectionbutton.
Note:TheSaveiconappearsabovethecenter
selectionbutton(DofFigure12).
8

6.WaituntiltheInfoCenterdisplaysthe“value
savedmessage”andtheredindicatorlight
illuminates.
SettingtheProtectSettings
Important:Usethisfunctiontolockandunlock
theapplicationrate.
Note:Youmustknowthe4-digitPINnumberto
changesettingsforfunctionsintheprotectedmenus.
1.Pressthecenterselectionbuttontohighlightthe
ProtectSettingsentry.
Note:Ifthereisno“X”intheboxtotheright
ofProtectSettingsentry,thesub-menusforL
Boom,CBoom,RBoom,andResetDefaults
arenotlockedwiththePIN(Figure14).
Figure13
2.Presstherightselectionbutton.
Note:ThePINentryscreenappears.
3.EnterthePIN;refertostep3inEnteringthePIN
intotheInfoCenter.
4.Oncetheright-mostvalueisset,presstheright
selectionbutton.
Note:TheCheckMarkiconappearsabovethe
centerselectionbutton.
5.Pressthecenterselectionbutton.
g028523
Figure14
8.WaituntiltheInfoCenterdisplaysthe“value
savedmessage”andtheredindicatorlight
illuminates.
Note:Thesub-menusbelowtheProtected
MenusentryarelockedwiththePIN.
Note:T oaccessthesub-menus,highlightthe
ProtectSettingsentry,presstherightselection
button,enterthePIN,andwhentheCheckMark
iconappears—pressthecenterselectionbutton.
SettingtheGeoLinkOption
RefertotheX25GeoLinkPrecisionSpraySystem
g028524
FinishingKitinstallationinstructionsforinformationon
enablingtheGeoLinkoption.
Note:UsingtheGeoLinksystemremovesseveral
functionsfromtheInfoCenter,including:
•Calibration
•T ankAlert,Units,andLeft,Center,RightBoom
fromtheSettingssubmenu
•FlowRate,FlowRateCalValue,andSpeedCal
ValuefromtheServicesubmenu
Thesefunctionswillbeavailableforuseonyour
GeoLinkmonitor.RefertotheX25GeoLinkPrecision
SpraySystemKitOperator’sManualformore
information.
Note:Thesub-menusforLBoom,CBoom,R
Boom,andResetDefaultsappear.
6.Pressthecenterselectionbuttontohighlightthe
ProtectSettingsentry.
7.Presstherightselectionbutton.
Note:An“X”appearsintheboxtotherightof
ProtectSettingsentry(Figure14).
TodisabletheGeoLinksystem:
1.Usethemiddleselectionbuttontonavigateto
theGEOLINKoption.
EnsurethatthecorrectPINcodeisentered;
refertostep3inUsingProtectedMenus(page
8).
2.Presstherightselectionbuttontodisablethe
GeoLinksystem(Figure14).
9

Figure15
SettingtheSprayerSectionSizes
1.Usethemiddleselectionbuttontoscrolltothe
sprayersectionthatyouwanttoedit.
•LBoom—80in
•CBoom—60in
•RBoom—80in
1.Usethemiddleselectionbuttontonavigateto
theRESETDEF AULTSoption.
2.Presstherightselectionbuttontoenterintothe
ResetDefaultsscreen.
3.PressthecenterselectionbuttonforYESorthe
leftselectionbuttonforNO.
Note:SelectingYESwillresetthesettingslisted
above.
Service
g203523
ToaccesstheServicescreen,usethemiddlebutton
tonavigatetotheSERVICEoption,thenpresstheright
buttontoenterintotheServicescreen(Figure17).
2.Usethemiddleselectionbuttonortheright
selectionbuttontoincreaseordecreasethe
selectedsprayersectionwidth(Figure16).
Note:Themiddleselectionbuttonallowsyou
todecreasethewidth;therightselectionbutton
allowsyoutoincreasethewidth.
Figure16
ResettingtheDefaultSettings
TheRESETDEFAUL TSoptionresetsthefollowing
settingstotheirfactorydefaults:
g202810
Figure17
ForinformationabouttheServicesubmenu,referto
ServiceScreens(page14).
g203192
•ApplicationRecording—subarea1
•T estSpeed—0.0
•HillAssist—enabled
•SprayTankAlert—1gal/ltr
•Units—US
10

Diagnostics
ToaccesstheDiagnosticsscreen,usethemiddle
buttontonavigatetotheDIAGNOSTICSoption,then
presstherightbuttontoenterintotheDiagnostics
screen(Figure18).
Figure18
CalibratingtheSprayer
RefertotheMultiPro1750TurfSprayerOperator’s
Manualforinformationoncalibratingthesprayer.
EnteringtheSprayTank
Volume
Usethespraytankvolumescreentoentertheamount
ofwaterlledintothetankbeforeyoubeginspraying.
Toaccessthespraytankvolumescreen:
1.Atthehomescreen,pressanybuttontoexpose
thenavigationpane.
2.Presstherightselectionbuttontonavigateto
thespraytankvolumescreen(Figure20).
g202809
ForinformationabouttheDiagnosticssubmenu,refer
toDiagnosticsScreens(page15).
About
ToaccesstheAboutscreen,usethemiddlebutton
tonavigatetotheABOUToption,thenpresstheright
buttontoenterintotheAboutscreen(Figure19).
Figure19
g203514
Figure20
1.Currenttankvolume2.Currentapplicationrate
Toenterthespraytankvolume:
1.Pressanybuttontoexposethenavigationpane.
2.Presstherightselectionbutton,thenpressthe
leftselectionbuttontoenterintothetankscreen
(Figure21).
g202808
ForinformationabouttheAboutsubmenu,seeAbout
Screens(page17).
11
1.Currenttankvolume
2.Increasetankvolume
g203520
Figure21
3.Decreasetankvolume

3.Usethecenterselectionbuttonandright
selectionbuttontoadjustthetankvolume
(Figure21).
DuringOperation
InfoCenterSprayArea
Screens
Usetheareascreenstogetinformationaboutthe
following:
•Areasprayed(acres,hectares,or1000ft
•Volumesprayed(USgallonorliters)
UsingtheTotalAreaScreen
Usethetotalareascreentoviewtheareaandthe
amountofproductsprayedsincethescreenwere
cleared(Figure22).
Totalareaandtotalvolumesprayedinformation
accumulatesuntilyouresetit.Presstheright
selectionbuttontoresetthetotalareaandtotal
volumeinformation.
Note:Resettingthetotalareaandtotalvolume
informationatthetotal-areascreenresetsallsub-area
andsub-areavolumeinformationforactiveand
inactivesub-areas.
AccessingtheTotalAreaScreen
UsingtheSub-AreaScreen
Thesub-areascreendisplaystheareaandthe
amountofproductsprayedinsub-areas(Figure23).
•Useanindividualsub-areaforeachsprayerjobat
yoursite.Youcanuseupto20sub-areastocollect
sprayerinformationforthesprayerjobsatthesite.
•Youcanuseinformationonthesub-areascreento
tracktheamountofareaandamountofchemical
sprayedforeachsprayerjobforwhichyoudene
asub-area.
•Areaandvolumesprayedinformationaccumulates
fortheactivesub-areainthesprayersystem
2
)
memoryuntilyouresetit.Presstherightselection
buttontoresetthesub-area.
Note:Resettingthetotalareaandtotalvolume
informationatthetotal-areascreenresetsall
sub-areaandsub-areavolumeinformationfor
activeandinactivesub-areas.
Note:Ifthevolumesprayedandareasprayed
dataforaselectedsub-areaiscleared,thesprayer
systemwilldeductthatsub-areavolumesprayed
andareasprayedquantityfromthetotalvolume
sprayedandtotalareasprayeddata.
•Ifthereisexistingdataintheactivesub-areathat
youdonotneed,resetareaandvolumesprayed
informationforthatsub-area.
AccessingtheSubAreaScreen
Toaccessthesubareascreen(Figure23)fromthe
totalareascreen,presstheleftselectionbutton.
Toaccessthetotalareascreen,pressanybuttonto
exposethenavigationpaneonthehomescreen,then
presstherightselectionbutton(Figure22).
Figure22
1.Cleartheapplication
recordtotal
2.Totalareaapplied(US
gallonshown)
3.Totalproductapplied
(acresshown)
g203249
Figure23
1.Sub-areanumber4.Totalareaapplied(US
2.Additionalsub-areas5.Totalproductapplied
g203250
3.Cleartheapplication
recordsub-area
UsingDifferentSub-Areas
Toaccumulatedatawithadifferentsub-area,usethe
middleselectionbuttontoselectthedesiredsub-area
number.
gallonshown)
(acresshown)
12

Note:Thenumbershowninthebox,locatedinthe
upperrightcornerofthescreen,indicatestheactive
sub-areawhereareaandvolumeinformationare
beingcollected.
InfoCenterAdvisories
Operatoradvisoriesautomaticallydisplayonthe
InfoCenterscreenwhenamachinefunctionrequires
additionalaction.Forexample,ifyouattemptto
starttheenginewhilepressingthetractionpedal,an
advisorydisplays,indicatingthatthetractionpedal
mustbeintheNEUTRALposition.
Foreachadvisorythatoccurs,thefaultindicator
ashes,andanadvisorycode(number),anadvisory
description,andanadvisoryqualierappearsonthe
screenasshowninFigure24.
Advisorydescriptionsandqualiersappear
asInfoCentericons.RefertoInfoCenterIcon
Descriptions(page3)foradescriptionofeachicon.
Note:Anadvisoryqualierexplainstheconditions
thattriggeredtheadvisoryandprovidesinstructions
oneliminatingtheadvisory.
Figure24
1.Faultindicator3.Advisorydescription
2.Advisoryqualier
Note:Advisoriesdonotlogintothefaultlog.
Note:Youcanclearanadvisoryfromthedisplay
screenbypressinganyoftheInfoCenterkeys.
RefertothefollowingtablefortheInfoCenter
advisories:
Advisories
AdvisoryCode
200
201
202
Description
StartPrevented—Pumpswitchactive
StartPrevented—NotinNEUTRAL
StartPrevented—Outofseat
4.Advisorycode
Advisories(cont'd.)
AdvisoryCode
203
204
205Parkingbrakeisengaged
206
207
208
209ThrottleLockPrevented—Parkingbrakeis
210
211
212Tanklowvolumealert
213
220Flowsensorcalibration
221Flowsensorcalibration—Fillwaterintank
222Flowsensorcalibration—Turnonthepump
223
224
225
226Flowsensorcalibration—Exitingcalibration
231
g202867
232
233
234
235
236
237
238
241
Description
StartPrevented—Throttlepedalisnothome
StartPrevented—Starterengagetimeout
PumpStartPrevented—Boomactive
PumpStartPrevented—Enginerpmhigh
Throttle/SpeedLockPrevented—Pumpis
notactive
notengaged
SpeedLockPrevented—Operatornotin
seatorparkingbrakeinengaged
Throttle/SpeedLockPrevented—Clutchor
servicebrakeisengaged
RinsepumpON
andentervolumelled
Flowsensorcalibration—Turnonallofthe
booms
Flowsensorcalibration—Calibration
commenced
Flowsensorcalibration—Calibration
complete
mode
Speedsensorcalibration
Speedsensorcalibration—Fillthefresh
watertank,pressnext
Speedsensorcalibration—Fillthesprayer
halffullwithwater,pressnext
Speedsensorcalibration—Enterthe
calibrationdistance,pressnext
Speedsensorcalibration—Markanddrive
theentereddistancewithsprayersections
off
Speedsensorcalibration—Speedsensor
calibrationinprogress
Speedsensorcalibration—Speedsensor
calibrationcomplete
Speedsensorcalibration—Turnoffthe
booms
Calibrationoutofbounds,usingdefault
13

Maintenance
ServiceScreens
ToaccesstheServicescreen,usethemiddlebutton
tonavigatetotheSERVICEoption,thenpresstheright
buttontoenterintotheServicescreen(Figure25).
Figure25
ViewingtheSprayerSystemFaults
1.Usethemiddleselectionbuttontoscrolltothe
FAULTSoption,thenpresstherightselection
buttontoenterintotheFaultsscreen(Figure26).
Figure26
2.ReviewthefaultslistedintheFaultsscreen
(Figure27).
g203637
Figure27
1.Faultitems
Thelistbelowidentiesthefaultcodesthatare
generatedbytheToroElectronicController(TEC)to
identifyanelectricalsystemmalfunctionthatoccurred
duringmachineoperation.Followthestepslisted
abovetoviewthefaults.
Note:Ifyouseefaultslistedintheviewer,contact
yourAuthorizedToroServiceDealer.
g202810
g202879
Faults
Code
Description
1
TECisfaulty
2
OneormoreoftheTECoutputfuses(7.5A)isfaulty
3
Mainpowerrelayorcircuitwiringisfaulty
4
Chargingsystemorcircuitwiringisfaulty
5
Startrelayorcircuitwiringisfaulty
6
Killrelaycircuitisfaulty
7
Spraypumpclutchorcircuitwiringisfaulty
8
Spraypumpindicatorlightorcircuitwiringisfaulty
9
Throttlelockorcircuitwiringisfaulty
10
Throttlelockindicatororcircuitwiringisfaulty
11
Masterboomvalveactuatororcircuitwiringisfaulty
12Rinsepumprelay,optionalrinsepump,orcircuitwiring
isfaulty
13
Brakeholdsolenoidorcircuitwiringisfaulty
14
InfoCentersoftwareisnotrecognizedbyTEC
15
Brakepressureswitchorcircuitwiringisfaulty(circuitis
closedeventhoughthebrakepedalhasbeenreleased)
16
Servicebrakeorthrottlehomesensor,orcircuitwiring,
isfaulty(circuitisopeneventhoughthebrakeor
acceleratorpedalhasbeenreleased)
17
Startertimeout(starterhasbeenengagedformore
than30seconds)
14

ViewingtheServiceHours
1.Usethemiddleselectionbuttontonavigateto
theHOURSoption(Figure28).
Figure28
2.Presstherightselectionbuttontoenterintothe
Hoursscreen.
3.Usethecounterinformationdisplayedonthe
screen(Figure29)todeterminethefollowing:
•Thenumberofhoursthattheignitionswitch
hasbeenintheRUNposition.
•Thenumberofhoursthattheenginehas
beenrunning.
•Thenumberofhoursremainingbeforethe
nextrecommendedservice
g203665
Figure30
FLOWCALVALUEselected
g202880
2.Presstherightselectionbuttontoselectthe
FLOWRATE,FLOWCALVALUE,orSPEEDCAL
VALUEoption.
DiagnosticsScreens
Thediagnosticsscreenlistsavarietyofmachine
operationsandthecurrentstateoftheinputs,the
qualiers,andtheoutputsrequiredtoallowthe
operationtoproceed.
Diagnosticsshouldbeusedtotroubleshootmachine
operationissuesandensurethatnecessary
componentsandcircuitwiringarefunctioning
correctly.
Figure29
1.Numberofhoursthatthe
ignitionswitchhasbeenin
theRUNposition
2.Numberofhoursthatthe
enginehasbeenrunning
3.Numberofhours
remainingbeforethenext
recommendedservice
ViewingtheFlowRate,Flow
Calibration,andSpeedCalibration
Toviewtheowrate,owcalibration,orspeed
calibration:
Toaccessthediagnosticsscreen,usethemiddle
buttontonavigatetotheDIAGNOSTICSoption,then
presstherightbuttontoenterintothediagnostics
screen(Figure31).
g203638
g202809
Figure31
1.Usethemiddleselectionbuttontonavigateto
theFLOWRATE,FLOWCALVALUE,orSPEEDCAL
VALUEoption.
15

Pumps
ThePumpsscreenidentiestherequirements
necessarytoallowoperationofthespraypumpand
theoptionalrinsepump.
TonavigatetothePumpsscreen,usethemiddle
selectionbuttontohighlightthePUMPSoption,then
presstherightselectionbuttontoenterintothe
Pumpsscreen(Figure32).
g202853
Figure33
Refertothefollowingtableforinputs,qualiers,and
outputsasdisplayedintheBoomsscreen:
BoomParametersTable
Figure32
Refertothefollowingtableforinputs,qualiers,and
outputsasdisplayedinthePumpsscreen:
PumpParametersTable
Inputs
SprayPump
Switch
MomentaryRinse
Switch(optional
rinsepumpkit)
TimedRinse
Switch(optional
rinsepumpkit)
QualiersOutputs
ThrottleHome
Switch
Timer(optional
rinsepumpkit)
SprayPumpClutch
RinsePump
(optionalrinse
pumpkit)
Booms
TheBoomsscreenidentiestherequirements
necessarytoallowoperationofthemasterboom
sprayvalve.
Inputs
g202855
LeftBoomSwitch
CenterBoom
Switch
RightBoomSwitch
MasterBoom
Switch
QualiersOutputs
NoneMasterBoom
SprayValve
EngineRun
TheEngineRunscreenidentiestherequirements
necessarytoallowfortheenginetostartandrun.
TonavigatetotheEngineRunscreen,usethemiddle
selectionbuttontohighlighttheENGINERUNoption,
thenpresstherightselectionbuttontoenterintothe
EngineRunscreen(Figure34).
TonavigatetotheBoomsscreen,usethemiddle
selectionbuttontohighlighttheBOOMSoption,then
presstherightselectionbuttontoenterintothe
Boomsscreen(Figure33).
g202854
Figure34
Refertothefollowingtableforinputs,qualiers,and
outputsasdisplayedintheEngineRunscreen:
16

EngineRunParametersTable
Inputs
KeyStartNeutralSwitchOKRUN
KeyRun
QualiersOutputs
SeatSwitchor
ParkingBrake
Switch
PumpSwitchOFF
StarterOutput
ThrottleLock
TheThrottleLockscreenidentiestherequirements
necessarytoallowforthethrottletoholdinitscurrent
position.
TonavigatetotheThrottleLockscreen,usethe
middleselectionbuttontohighlighttheTHROTTLELOCK
option,thenpresstherightselectionbuttontoenter
intotheThrottleLockscreen(Figure35).
AboutScreens
InformationintheAboutscreenincludesthemodel
number,serialnumber,andtherevisionnumberof
thesoftwareversion.
1.Toaccesstheaboutscreen,usethemiddle
buttontonavigatetotheABOUToption,then
presstherightbuttontoenterintotheAbout
screen(Figure36).
Figure35
Refertothefollowingtableforinputs,qualiers,and
outputsasdisplayedintheThrottleLockscreen:
ThrottleLockParametersTable
Inputs
Speed
Lock/ThrottleLock
Switch
QualiersOutputs
NeutralSwitchSpeed
Lock/ThrottleLock
Solenoid
ParkingBrake
Switch
SprayPumpSwitch
ClutchSwitch
g202808
Figure36
2.Usethemiddleselectionbuttontoscrollthrough
theaboutscreenitems(Figure37).
g202856
g202838
Figure37
17

Notes:

Notes: