Toro 108-9699 Installation Instructions

Form No. 3353-789 Rev B
Temperature Sender Kit
For Groundsmaster 1000L Traction Units
Model No. 108–9699
Installation Instructions
Installation
1. Disconnect the battery cables.
2. Disconnect the w ires from the temperature sender on the engine (Figure 1).
3. Remove the temperature sender from the engine adapter (Figure 1). Do not remove the sender adapter from the engine.
1
8. Remove the clamp securing the temperature gauge to the control panel. Remove the gaug e.
9. Mount the new temperature gauge to the control panel with the clamp and fasteners supplied.
10. Route the wire harness, along the existing harness, to the new temperature gauge.
1
2
G001310
Figure 2
1. Temperature gauge
2. Mounting clamp
G001309
Figure 1
1. Temperature sender
4. Install the new temperature sender switch to the engine.
5. Connect the ring terminal, of the new wire harness, to the new temperature sender with the insulated washer, atwasher, lockwasher andhexnut.Tightenthenuttonomorethan 20 in.-lbs.
6. Plug the (2) sender wires to the new wire harness.
7. Disconnect all the wires from the temperature gauge (Figure 2). Note mounting position of wires on gauge.
© 2005—The Toro® Company 8111 Lyndale Avenue South Bloomington, MN 55420
Register at www.Toro.com. Original Instructions (EN)
11. Reconnect the existing wires to the new temperature gauge.
12. Connect the bullet terminal, from the new harness, to the four t h stud on the gauge (red decal on stud).
13. Secure the harness with cable ties. Keep harness away from any hot, sharp or moving parts.
14. Reconnect the battery cables.
Printed in the USA. All Rights Reserved