Toro 100 Plus Series Valves Specifications

Micro-Irrigation
100 Series Plus
Application:
These heavy-duty globe/angle valves offer superior perform­ance and durability under the most demanding conditions. The 100 Series Century Plus valve delivers a host of features and reliable performance, which makes it suitable for agricul­tural, commercial and industrial applications.
1", 11⁄2", 2" and 3"
plastic models
Features:
Performance
• Flow range from 5-300 GPM
• Manual internal bleed
• Manual external bleed (flush mode)
• Brass flow control stem (2 and 3-inch models)
• Flow control allows precise flow adjustment and manual shutoff
Anti - Contamination 102 models
• Electric valves with 150-mesh external control water filter and three-way solenoid
Quality Construction
• Glass-reinforced nylon, stainless steel and brass construction withstands high temperatures and system surges under pressure
• Rugged, nylon-reinforced Buna-N diaphragm provides leak-proof seal
• Buna-N valve seat seal
• Captive plunger
• Stainless steel metering
• Molded-in and anchored studs allow positive bonnet attachment and removal
• Easily serviced without removal from the system
• Non-continuous metering system for dirty or effluent water applications
• Small exchange of control water allows minimum filter capacity
• Control water filter allows easy external service
• Selectable normally open or normally closed mode
• Working pressure range from 10-100 psi
100 Series Plus
Globe Angle Valves
Pressure Regulation
213 Models
• Manual downstream pressure regulating valves
• Available in downstream sens­ing in 20–100 or 0–30 psi (1,4–6,9 or 0–2 bar) range
• Self-modulating pressure regu­lator maintains constant down­stream pressure within +/- 2 psi (0,14 bar) of pressure setting [for in-valve sensing; within +/­1 psi (0,07 bar) for down­stream sensing]
• All flow ranges must be within recommended range indicated on pressure loss chart — mini­mum 15 gpm (0,9 l/s) recom­mended for 103 and 213 models
• Inlet pressure must be 15 psi (1,03 bar) greater than desired outlet pressure
Electrical Specifications
• Solenoid: 24 VAC
• Inrush volt-amp: 24 VAC-11.50 VA
• Inrush current: .4 amp (102 models: .48 amp)
• Holding volt-amp: 24 VAC-5.75 VA
• Holding current: .2 amp (102 models: .24 amp)
Optional Accessories
• Hydraulic conversion kit (HVC-Kit)
• Reclaimed water kit (RW60-Kit)
• DC latching solenoid (E2002)
Example:
ow To Order:
H
A-100P 1 -LS
odel
M
-100P1 1" yes
A A-100P1.5 1.5" yes
-100P2 2" yes
A A-100P3 3" yes
-100P1-LS 1" no
A A-100P1.5LS 1.5" no A-100P2-LS 2" no
-100P3-LS 3" no
A
A-102P 1 DS
Model Size Solenoid
-102P1 1" yes
A A-102P1.5 1.5" yes
-102P2 2" yes
A A-102P3 3" yes
Pressure Regulating
ownstream Sensing 0–100psi
D
213P1-100DS 1" no
13P1.5-100DS 1.5" no
2 213P2-100DS 2" no
Downstream Sensing 0–30psi
213P1-30DS 1" no 213P1.5-30DS 1.5" no 213P2-30DS 2" no
ize
S
olenoid
S
Flow Rate (GPM)
Model Style Size 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 175 200 225 250 275 300
A-100P1/A-102P1 213P1-100DS 213P1-30DS
A-100P1.5/A-102P1.5 213P1.5-100DS 213P1.5-30DS
A-100P2/A-102P2 213P2-100DS 213P2-30DS
A-100P3/A-102P3 213P3-100DS 213P3-30DS
NOTES: (1) When designing a system, the industry standard for flow rate velocity through pipes and fittings is 5 Fps (2m/s).
The ToroCompany Micro-Irrigation Business
1588 N. Marshall Avenue, El Cajon, CA 92020-1523, USA Tel: +1(800) 333-8125 or +1 (619) 562-2950 Fax: +1 (800) 892-1822 or +1 (619) 258-9973
(2) Pressure loss data is derived from valves independently tested by C.I.T., Fresno, CA. (3) Hydraulic actuated valves vented to atmosphere will show lower pressure loss figures at low flows (HVC-Kit). (4) Pressure regulating valves must operate in the recommended flow ranges – For the best pressure regulation the valves should
be sized at the upper end of the flow range. ex: for 100 gpm the 1
Globe
Angle 4.2 3.1 2.7 4.8 7.9
Globe
Angle 1.3 1.6 2.8 4.0 5.5 7.1 9.0 11.0 13.3
Globe
Angle 1.2 1.6 2.0 2.4 2.8 3.3 3.9 4.4
Globe
Angle 1.9 2.4 3.3 4.3 5.5 6.9 8.5
4.2 3.2 4.1 7.2 10.9
1"
11/2"
2"
3"
1.6 2.3 3.6 5.2 7.0 9.2 11.7 14.4 17.5
2.1 2.7 3.3 4.0 4.8 5.6 6.5 7.5
1
/2" valve should be specified instead of the 2" valve.
2.5 3.0 4.1 5.3 6.7 8.3 10.1
toromicroirrigation.com
ALT011 02/10
Pressure Loss PSI