PUMP & HEATING ELEMENT .......................................... PAGE 22
HEATING ELEMENT W/ FITTINGS .................................. PAGE 23
ELECTRICAL & PLUMBING SYSTEM .............................. PAGE 24
Page 3
Tornado® Standard Warranty Program*
10 Years:
Warranties do not cover components
subject to normal wear or abuse and
misuse, and have other limitations not
specified here. For full details,
contact your Authorized Tornado
Distributor, Service Center, or the
Tornado Technical Service
Department.
Parts on all Tornado and Tornado/Karcher
All plastic tanks and
rotationally-molded bodies
2 Years:
cleaning equipment
1) 2) 3) 5)
1) 5)
Tornado sales and services
representatives are not
authorized to waive or alter the
terms of this warranty, or to
increase the obligations of
Tornado under the warranty.
Labor on all Tornado and Tornado/Karcher
cleaning equipment
1 Year:
2) 5)
1 Year:
Warranty on batteries and chargers,
One year pro-rated.
* Effective January 1st, 2001. Terms subject to change without notice.
1) Windshear™ Blower-Dryer, Insulation Blowers, T191, T201, CV 30, CV 38, CW 50, CW 100, Pro PAC Vacs,
Duo-Upright Carpetkeepers™, and all chargers are warranted for 1 (one) year for both parts and labor.
2) Warranties on all riding sweepers including the ICC1, KM 100/100 R, KMR 1250, and KMR 1700 are 24
months parts/6 months labor OR 1000 hours of operation, whichever comes first. Warranties on the
75/140 & 90/140 are 24 months parts/12 months’ labor OR 1000 hours of operation, whichever comes first.
3) All non-wear item parts purchased after warranty expiration are warranted for 90 days.
4) Warranty starts from date of sale to the consumer or, at Tornado’s discretion, 6 months after dealer
purchased the unit from Tornado, whichever comes first.
5) See limited 2-year pressure washer warranty.
Page 4
Inspection
Unpack and inspect your extractor for shipping damage. Each unit is tested and inspected prior to
shipping. For any concerns regarding shipping damage, contact your dealer immediately. All returns
must have a Return Authorization (RA) number.
Grounding Instructions
The extractor MUST BE GROUNDED. If the machine should stop working or malfunction, grounding
offers a path of least resistance for electrical current, reducing the risk of electrical shock. This
machine is equipped with a cord that has an equipment grounding conductor and a grounding plug.
The plug must be inserted into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Cutting off the ground wire or using a cord that is not
properly grounded will void the manufacturers warranty on this machine.
Safety
Warning - To reduce the risk of fire, electrical shock or Injury:
• READ ALL INSTRUCTIONS BEFORE USING.
• Use only as described in this manual.
• Plug power cord Into the nearest outlet (20A preferred).
• Never attempt any adjustments or repairs while the machine is plugged in.
• Do not use outdoors, in standing water, or on wet surfaces.
• Pay close attention when using unit near children.
• Do not leave unit outdoors, or in extreme heat or cold. Harsh weather elements will damage
components and void warranty.
• Lift using only the appropriate handles.
• Always wear appropriate clothing and safety equipment when operating unit.
• Keep all body parts, hair, and loose clothing away from openings and moving parts
• Use extra care when cleaning on stairs. Do not move up or down stairs with fluid in the unit.
• Use common sense to protect yourself and others from injury when using an extractor.
Warnings
• Do not run the pump without water in the solution tank.
• Do not use hot liquids in the solution tank.
• Do not pick up combustible or flammable materials.
• Do not use your extractor with a damaged cord.
• Do not operate without the float shut-off assembly in place.
Precautions
• Do not run the pump dry. This will void the manufacturer warranty.
• Do not run hot fluids through the pump. This can cause pump cavitation and will void the warranty.
This is a water-cooled pump.
• Always be sure the solution tank and hoses and filters are clear of debris. Running the pump with
clogged filters or hoses can cause pump damage.
• Replace any damaged cords or hoses before use.
Chemical Use
• Only use chemicals approved for use with extraction.
• Keep the appropriate MSDS sheets onhand at all times.
• Flush the solution pump with clean water after each use to extend the life of the pump.
Page 5
Electrical
• Do not pull your machine by, close a door on, or run over the cord, and keep it away from heated
surfaces.
• Do not pull onthe cord to unplug the machine.
• Turn all machine switches to OFF before unplugging.
• Connect to a properly grounded outlet only.
Operational Instructions
• Use only a (20 amp) electrical outlet, usually found In Bathroom, Kitchens, or Laundry rooms. Plug
your machine in.
• Attach vacuum and solution hoses to appropriate connections on the machine and your wand. As
you do this, always Inspect hoses for cracks or fraying. Do not use if hoses are cracked or frayed.
• Mix water and approved extractor detergent in the solution tank at the front of the machine. Use a
clean hose to fill the solution tank. If a hose is not available, use a clean bucket. DO NOT
OVERFILL.
Machine Maintenance
1. Regular dally maintenance Is required to keep this equipment In the best working condition. A
detailed list of preventative maintenance is outlined below. Thoroughly clean all equipment and
accessories after each use:
• Rinse solution and vacuum recovery tank with clean water.
• Flush entire pumping system with clean water. This includes all solution hoses and wand(s).
Do not allow liquids to remain in equipment after use.
• Clean all filters and dump valve.
2. The solution system has one filter located in the solution tank, and high-pressure machines
(200psi and higher) have an in-line filter in the pump compartment. Check filters dally and clean
when dirty in order for them to properly filter debris from the solution tank. If the filter Is missing or
becomes damaged It must be replaced before the machine Is used.
3. Lubricate all quick disconnects with a quality silicone lubricant.
4. Do not use the same pail to fill the solution tank that is used to empty the waste tank. This would
introduce dirt and debris into the solution lines, block the fitters, orifices, and generally degrade
the pumping system.
Winterizing Your Extractor
This unit should be winterized between uses if it is to be exposed to freezing temperatures. To
winterize your machine, pour a 50/50 mix of anti-freeze and water into the empty solution tank. Aim
the spray gun into the solution tank. Run the pump and spray the gun into the solution tank until the
fluid flows from the gun into the tank.
Serial #'s
The serial number is located on the back of the machine just above the dump valve.
Page 6
ACCESSORIES FOR ALL MODELS
Page 7
12 GALLON CARPETRINSER/DRYERS
98242
Item #QtyPart #Description
1220002Vac Motor 2-Stage
2220003Gasket Vac Motor
4As Reqd20006Screws for Pump Mounting
5120007Heating Element
7120009Pump-100 PSI 2-Stage
8120010Hose-Vacuum 1.5" (Blk)