TOREX XBS303V17R-G User Manual

A
XBS303V17R-G
Schottky Barrier Diode, 3A, 30V Type
FEATURES
Forward Voltage : VF=0.355V (TYP.) Forward Current : I Repetitive Peak Reverse Voltage : V
BSOLUTE MAXIMUM RATINGS
Ta=25
PARAMETER SYMBOL RATINGS UNIT Repetitive Peak Reverse Voltage VRM 30 V Reverse Voltage (DC) VR 30 V Forward Current (Average) IF(AVE) 3 A Non Continuous
Forward Surge Current Junction Temperature Tj 125 Storage Temperature Range Tstg
*1 Non continuous high amplitude 60Hz half-sine wave.
* When the IC is operated continuously under high load conditions such as high temperature,
high current and high voltage, it may have the case that reliability reduces drastically even if under the absolute maximum ratings. Adequate “Derating” should be taken into consideration while designing.
MARKING RULE
*1
I
FSM 60 A
=3A
F(AVE)
=30V
RM
-55+150
ETR1614-001a
APPLICATIONS
Rectification
Protection against reverse connection of battery
PACKAGING INFORMATION
Cathode Bar
①②③④⑤⑥: 303V17(Product Number) ⑦⑧ : Assembly Lot Number
PRODUCT NAME
PRODUCT NAME DEVICE ORIENTATION XBS303V17R-G SMA (Halogen & Antimony free) XBS303V17R SMA
* The “-G” suffix indicates that the products are Halogen and Antimony free as well as being fully RoHS compliant. * The device orientation is fixed in its embossed tape pocket.
ELECTRICAL CHARACTERISTICS
Ta=25
PARAMETER SYMBOL TEST CONDITIONS
VF1 IF=0.5A - 0.265 0.34 V
Forward Voltage
Reverse Current IR VR=30V - 0.35 3 mA Inter-Terminal Capacity Ct VR=1V , f=1MHz - 385 - pF
Reverse Recovery Time*2 trr IF=IR=10mA , irr=1mA - 90 - ns
*2trr measurement circuit
Pulse Generatrix
VF2 IF=1A - 0.295 0.36 V
F3 I
V
=3A - 0.355 0.39 V
F
Bias Device Under test
Oscilloscope
SMA
MIN. TYP. MAX.
Unit: mm
LIMITS
UNIT
1/3
XBS303V17R-G
TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage (2) Reverse Current vs. Reverse Voltage
(mA)
R
Reverse Current: IR (mA)
Reverse Current I
100
10
Ta=125℃
100℃
75℃
1
0.1
25℃
0.01 0102030
Rever se Volt age V
R
(V)
10
(A)
F
1
Forward Current I
Forward Current: IF (A)
0.1
Ta=125℃
75℃
-25℃
25℃
0.01 0 0.2 0.4 0.6
Forward Voltage: VF (V) Reverse Voltage: VR (V)
Forward Voltage V
F
(V)
(3) Forward Voltage vs. Operating Temperature (4) Reverse Current vs. Operating Temperature
0.6
(V)
F
0.4
100
10
(mA)
R
V
=20V
10V
5V 1V
Reverse Current I
Reverse Current: IR (mA)
1
0.1
0.01 0 50 100 150
Operating Temperature Ta ()
0.2
Forward Voltage V
Forward Voltage: VF (V)
0.0
-50 0 50 100 150
Operating Temperature: Ta () Operating Temperature: Ta ()
Operating Temperature Ta ()
I
1.5A
0.5A
0.1A
=3A
(5) Inter-Terminal Capacity vs. Reverse Voltage (6) Average Forward Current vs. Operating Temperature
1000
Ta=25℃
800
4.0
(A)
AV
3.0
600
2.0
400
1.0
Average Forward Current IF
Average Forward Current: IFAV (A)
0.0
0 50 100 150
Inter-Terminal Capacity Ct (pF)
Inter-Terminal Capacity: Ct (pF)
200
0
0102030
2/3
Reverse Voltage V
R
(V)
Operating Temperature Ta ()
Operating Temperature: Ta () Reverse Voltage: VR (V)
Loading...