TOREX XBS104V14R-G User Manual

A
y
r
p
XBS104V14R-G
ETR1610-002
Schottky Barrier Diode, 1A, 40V Type
FEATURES
Forward Voltage : VF=0.365V (TYP.) Forward Current : I Repetitive Peak Reverse Voltage : V Environmentally Friendly : EU RoHS Compliant, Pb Free
Ta=25
Ta=25
*2trr measurement circuit
BSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL RATINGS UNIT
Repetitive Peak Reverse Voltage VRM 40 V Reverse Voltage (DC) VR 40 V Forward Current (Average) IF(AV) 1 A Non Continuous Forward Surge Current Junction Temperature Tj 125 Storage Temperature Range Tstg
*1 Non continuous high amplitude 60Hz half-sine wave.
* When the IC is operated continuously under high load conditions such as high temperature,
high current and high voltage, it may have the case that reliability reduces drastically even if under the absolute maximum ratings. Adequate “Derating” should be taken into consideration while designing.
MARKING RULE
PRODUCT NAME
XBS104V14R-G SOD-123A(Halogen & Antimony free)
XBS104V14R SOD-123A * The “-G” suffix indicates that the products are Halogen and Antimony free as well as being fully RoHS compliant. * The device orientation is fixed in its embossed tape pocket.
*1
I
ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL TEST CONDITIONS
VF1 IF=100mA - 0.23 0.315 V
Forward Voltage
Reverse Current IR VR=40V - 0.25 2 mA Inter-Terminal Capacity Ct VR=1V , f=1MHz - 150 - pF
Reverse Recovery Time*2 trr IF=IR=10mA , irr=1mA - 41 - ns
VF2 IF=500mA - 0.30 0.385 V
F3 I
V
=1A
F(AV)
=40V
RM
FSM 20 A
-55+150
: 0 (Product Number) : Assembl
F
Bias Device Under test
Lot Numbe
=1A - 0.365 0.41 V
APPLICATIONS
Rectification
Protection against reverse connection of battery
PACKAGING INFORMATION
Cathode Bar
SOD-123A
MIN. TYP. MAX.
Unit : mm
LIMITS
UNIT
Pulse Generatrix
Oscillosco
e
1/3
XBS104V14R-G
TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage (2) Reverse Current vs. Reverse Voltage
1
Ta=125℃
(A)
F
0.1
-25℃
25℃75℃
100
10
(mA)
R
Ta=100℃
75℃
1
Forward Current I
Forward Current: IF (A)
0.01
0.001 0 0.2 0.4 0.6
Forward Voltage: VF (V) Reverse Voltage: VR (V)
Forward Voltage V
F
(V)
Reverse Current: IR (mA)
Reverse Current I
0.1
0.01
0.001 0 10203040
Reverse Voltage V
25℃
R
(V)
(3) Forward Voltage vs. Operating Temperature (4) Reverse Current vs. Operating Temperature
0.6
100
10
(V)
F
0.4
(uA)
R
1
VR=10V
5V 1V
0.2
Forward Voltage V
Forward Voltage: VF (V)
0.0
-50 0 50 100 150
Operating Temperature: Ta () Operating Temperature: Ta ()
Operating Temperature Ta ()
IF=1A
0.5A
0.1A
Reverse Current: IR (μA)
0.1
Reverse Current I
0.01
0.001 0 50 100 150
Operating Temperature Ta ()
(5) Inter-Terminal Capacity vs. Reverse Voltage (6) Average Forward Current vs. Operating Temperature
500
400
2.0
(A)
AV
1.5
300
1.0
200
0.5
Average Forward Current IF
Average Forward Current: IFAV (A)
0.0 0 50 100 150
Inter-Terminal Capacity Ct (pF)
Inter-Terminal Capacity: Ct (pF)
100
0
0 10 203040
2/3
Rever se Volt age V
R
(V)
Operating Temperature Ta ()
Operating Temperature: Ta () Reverse Voltage: VR (V)
Loading...