TOREX XBS053V15R-G User Manual

A
y
r
XBS053V15R-G
Schottky Barrier Diode, 500mA, 30V Type
FEATURES
Forward Voltage Forward Current Repetitive Peak Reverse Voltage : V Environmentally Friendly
Ta=25
BSOLUTE MAXIMUM RATINGS
Repetitive Peak Reverse Voltage VRM 30 V Reverse Voltage (DC) VR 20 V Forward Current (Average) IF(AV) 500 mA Non Continuous Forward Surge Current Junction Temperature Tj 125 Storage Temperature Range Tstg
*1 Non continuous high amplitude 60Hz half-sine wave.
MARKING RULE
PARAMETER SYMBOL RATINGS UNIT
: VF=0.40V (TYP.) : I
*1
=500mA
F(AV)
=30V
RM
: EU RoHS Compliant, Pb Free
FSM 5 A
I
-55+150
ETR1607-003
APPLICATIONS
Rectification
Protection against reverse connection of battery
PACKAGING INFORMATION
Cathode Bar
: 2 (Product Number)
PRODUCT NAME
PRODUCT NAME DEVICE ORIENTATION
XBS053V15R-G SOD-523(Halogen & Antimony free)
XBS053V15R SOD-523 * The “-G” suffix indicates that the products are Halogen and Antimony free as well as being fully RoHS compliant. * The device orientation is fixed in its embossed tape pocket.
ELECTRICAL CHARACTERISTICS
Ta=25
PARAMETER SYMBOL TEST CONDITIONS
Forward Voltage
Reverse Current IR VR=20V - - 100 Inter-Terminal Capacity Ct VR=10V , f=1MHz - 12 - pF
Reverse Recovery Time *2 trr IF=IR=10mA , irr=1mA - 8 - ns
*2trr measurement circuit
Bias
: Assembl
VF1 IF=100mA - 0.28 - V V
F2 I
Device Under Test
Lot Numbe
=500mA - 0.40 0.47 V
F
SOD-523
MIN. TYP. MAX.
Unit : mm
LIMITS
UNIT
μA
Pulse Generatrix
Oscilloscope
1/3
XBS053V15R-G
TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage (2) Reverse Current vs. Reverse Voltage
1
100
Ta=125℃
10
(A)
F
0.1
Ta=125℃
-25℃
(mA)
R
1
25℃75℃
0.1
0.01
Forward Current I
Forward Current: IF (A)
0.001 0 0.2 0.4 0.6
Forward Voltage: VF (V) Reverse Voltage: VR (V)
Forward Voltage V
F
(V)
Reverse Current: IR (A) Reverse Current: IR (A)
Reverse Current I
0.01
0.001 0102030
Reverse Voltage V
R
(V)
(3) Forward Voltage vs. Operating Temperature (4) Reverse Current vs. Operating Temperature
0.6
100
10
(V)
F
0.4
IF=0.5A
(mA)
R
1
75℃
25℃
VR=20V
10V
5V
0.2
Forward Voltage V
Forward Voltage: VF (V)
0.0
-50 0 50 100 150
Operating Temperature: Ta () Operating Temperature: Ta ()
Operating Temperature Ta ()
0.1A
0.01A
0.1
Reverse Current I
0.01
0.001 0 50 100 150
Operating Temperature Ta ()
(5) Inter-Terminal Capacity vs. Reverse Voltage (6) Average Forward Current vs. Operating Temperature
100
75
50
25
Inter-Terminal Capacity Ct (pF)
Inter-Terminal Capacity: Ct (pF)
Ta=25℃
0
0102030
1.0
(A)
AV
0.8
0.5
0.3
Average Forward Current IF
Average Forward Current: IFAV (A)
0.0 0 50 100 150
2/3
Reverse Voltage V
R
(V)
Operating Temperature Ta ()
Operating Temperature: Ta () Reverse Voltage: VR (V)
Loading...
+ 1 hidden pages