6
NEW FEATURES ON T955W
New Features on the T955W After R251W is Connected
Example of programming a priority for the SLEEP time period:
In this example system we have 1 T955W on the main floor and 1 R251W in the Master Bedroom on the 2nd
floor. During the setup process the R251W was named Bedroom 1. During WAKE, LEAVE and RETURN, the
program should remain on system average. When on the SLEEP time period during programming, press
NEXT ZONE until Bedroom 1 shows. During the SLEEP time period the other remotes in the house will be
ignored and the system will be controlled only by the ambient temperature of the R251W in the master
bedroom. The WAKE, LEAVE and RETURN temperature will be controlled by the system average.
NEXT ZONE KEY SETPOINT NOT DISPLAYED
THERMOSTAT HOLD (PERMANENT) TEMPORARY HOLD (4 HOURS)
NEXT ZONE key cycles
through ambient temperatures
for connected zones.
Setpoint will only be displayed for the
zone currently being used by the
program or in hold. Press the or
to show the setpoint for adjustment.
To put the thermostat into hold
select system average or the zone
you want to hold. Then use the
arrows to adjust the setpoint.
Then press the HOLD key.
REMOTE: Indicates the T955W is in
temporary hold. The setpoint will now
display the temporary override setpoint.
The name of the
remote sensor will
be displayed.
In this example, it is
REMOTE 2.
HOLD: Indicates
the T955W is in
permanent HOLD.
A permanent
HOLD can be
active for system
average, local, or
any R251W.
Run Schedule:
Will cancel any
holds and return
the system to the
program.
Run Schedule:
Will cancel any
holds and return
the system to
the program.
In this example,
the name of the
zone currently
having priority is
SYSTEM AVERAGE.
System average
is the average of all
connected sensors.
Local is the ambient
temperature of the
T955W.
The name of the
R251W can be
displayed. This
shows it has priority.