2. Configuration of Device Connection on Initial Page
3. Input DSP Channel
4. MATRIX
5. Output DSP Channel
6. Save/Load/Copy
7. System
7. Web Configuration of LAN Module
8. Hookup Diagram
9. Block Diagram
10. Technical information
11. Guarantee
12.Notes
4
4
4
5
7
9
9
9
10
13
14
15
16
17
18
19
20
21
22
under the EM disturbance, the ratio of signal-noise may be changed above 3dB.
* The mixer for professional use. They can be used in following electromagnetic environment: residential,
commercial and light industrial, urban outdoors.
They are the apparatus not intended for rack mounting.
* The peak inrush currents equal to 8.33 A.
*This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)this device may not cause harmful interference, and (2)this device must accept any interference received,
including interference that may cause undesired operation. Changes or modifications not expressly
approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
3
1
Introduction
Thank you for choosing TOPP PRO. The new TOPP PRO MUSIC GEAR RT-DRIVE DLM808 is an
audio matrix processor, with 8 input and 8 output channels, with high-definition LCD to display
current status at real time, with network port to expand network devices. It is available for
large-scale place, such as theater, broadcast hall, gymnasium and conference center and so on.
Every TOPP PRO audio product is strictly tested and complied to very strict standards.
Please carefully read this manual before starting operation! Thank you again for choosing TOPP PRO MUSIC GEAR RT-DRIVE DLM808.
Features
2
3
All input channels are equipped with GATE/EXP/CROSSOVER/PEQ/DELAY/COMPRESSOR function
All input channels are equipped with Gain/Crossover/PHASE/PEQ/DELAY/COMPRESSOR function
8 in / 8 out audio matrix processor
With 8 channels in and 8 channels out audio interface expansion card (DANTE)
Match with PC and App operation software, which is convenient for user
User can on-line update DSP and MCU Firmware via internet
4
Function Buttons and LED Indicators
3
1
5
2
1. LCD Screen
Display device information, such as device name, port number, preset etc.
1) Initial page
1
2
3
567
(1) Device name
(2) Current preset
(3) Current release version
(4) Current ID, when connecting with device, the ID can be obtained automatically.
(5) This image means the PC isn’t connecting with DLM808; if connecting well, the two devices
inside box will flash alternately.
(6) This image means DSP communication well, if faulty, it will show DSP!.
(7) This image appears when Dante option inserted in DLM808, or it will disappear.
4
4
6
7
4
2) Preset list
2. UP and DOWN buttons (PRESET and ENTER)
The two buttons can meet operation demands of LCD screen.
-UP: Click to list up.
-DOWN: Click to list down.
-PRESET: Function as following
1) Enter Preset List
Press this button for about 3 seconds to enter “Recall Preset” page, you can see totally 32
presets, every preset can be set at PC, after finishing the setting, then save the preset, it can
be synchronously saved to DLM808.
2) Exit from Current Page
In“Recall Preset”page, press PRESET button again for 3~4 seconds. exit from current page
to initial page.
3) Indicate System Information
In initial page, press PRESET button for 3~4 seconds, you can see system information
showed on LCD screen, such as system version(System V1.0), firmware version(Firmware
V1.0).
5
4
Function Buttons and LED Indicators
- ENTER. Function as following
1) Load Preset
Click UP/DOWN button to select preset, then press the “ENTER” button for about 3 seconds to
recall the selected preset. After recalling successfully, the screen will display “Load OK”.
2) Exit from Preset List Page
When the selected preset is empty, press ENTER for 3 seconds, no preset to load, the system
will exit from current page and return back to initial page.
3) Default setting
press both PRESET and ENTER buttons for 8 seconds to erase all memory settings, for default
setting.
Note that whichever page it is, if hang it without any operation, the system will go back to
initial page about 5 seconds later.
3. Input Signal LED indicating
Indicate input connection status. When you connect this device to other host, the LEDs indicate
corresponding Mic port connection status at back panel.
LEDs indicate as below:
-CLIP(RED). It means current MIC input signal overload.
-SIG(GREEN). It means some signal input from current MIC port.
4. Input Channel MUTE Button
Press CH1-8 buttons, the corresponding background LED light, which means to mute signal from
selected channels.
5. Output Signal Indicating LED
Indicate output connection status. When you connect this device to other hosts, LEDs here
indicate corresponding XLR port connection status at back panel.
LEDs indicate as below:
-CLIP(RED). It means current XLR output signal overload.
-SIG(GREEN). It means some signal output from current XLR port.
6. Output Channel Select Button
Press CH1-8 buttons, the corresponding background LED light, which means signal can output
from selected channels.
7. Status LED Indication
LED indicating as below:
-COMM.(GREEN). Power on DLM808 and connect it with PC by router, then open DLM808’s
software control page on PC, it lights if communication is common; while it turns off if
communication is fault.
-FAULT(RED). It lights when DSP runs fault, you can see fault information on LCD screen, see
details in section 1 about LCD Screen. At this time please check your device configuration.
6
Rear Panel
Rear Panel
8
9
111213161510
8. MIC Input Port1~8
3 poles XLR input. These ports are used for connecting input device of analog microphone or line
input devices. Please be sure that MIC input port supports phantom power.
9. XLR Output Port 1~8
These ports are used for connecting analog line output device, such as Amplifier and Speaker.
10. RS-232 Input Port
It can connect other device via RS232 data line, T represents Transmitting end, R represents
receiving end, while G represents ground. DLM808 can control this device’s action. Such as
selecting two audio channel or mute whole system by device connected to this port.
Below table lists the whole command of RS-232:
140x010x200x03240x0D16Bytes ASCILL code0x40Set device name
150x010x200x0380x0E0x000x40Get Device information
16 0x01 0x20 0x03 29
170x010x200x0380x0FPreset Number 0-320x40Recall Preset
0x0E
Byte 8:Mixer Input channel 8
Byte 9:Mixer Digital Input 1
Byte 10:Mixer Digital Input 2
…
Byte 15:Mixer Digital Input 8
Byte 0-15 : Device name ,ASCILL
Byte 16: Firmware Version
Byte 17-21: Device Serial Number
11. RC-NET Input/Output Port
Control signal can transmit through this network port.
RC-Net is based on RS-485 transport protocol, which owns function of RS485 data exchange, to
realize large-scale real data transmit.
Device output the Output
0x40
Mixer status
Device output Device
0x40
information
12. LAN& RC-NET Switch
Use this switch to choice Network control way, you can determine to control it by Ethernet or
RC-NET.
13. LAN Network Control Port
DLM808 can connect with Ethernet switch via this port. On LAN network control port, you can
see two LEDs, they are connection status indicator (green) and signal transmit indicator(yellow).
-- If the yellow LED goes out, means no signal transmits; while if yellow LED is on, but green one
goes out, means the device detects network, but no connection.
-- If green LED is on ,means network connects well.
14. Optional Module
Usually it is prepared for DANTE module to insert in, which can be used for audio input/output
expansion.
15. Power Inlet
Connect AC voltage, 100-240VAC, 50-60Hz.
16. Power Switch
Press it to turn on/off the device.
8
DSP Control
DLM808 can connect with PC by internet
port on router. After successfully connected,
please click the file named SystemEditor on
PC, you can see initial page as below picture
shows, which can set connection of each
device.
1. Configuration of IP Address
When connect DLM808 with PC by internet port on router:
Before connect devices on software control page, please set IP
address of DLM808 and router first, below gives steps(pay
attention that the toggle switch on DLM808 rear panel should be
at LAN side):
1). Click “Connect” control on top right corner, a search dialog will
jump up, click “Scan” button, it will automatically search IP and
MAC address in the system, as below picture shows. Then click
“Connect” button to build communication. The “Status” control in
top right corner indicates the communication status, which will
light green if connect right, while off means fail to connect.
6
2). If fail to connect following above step, then please key the IP address in “Choose IP” text field,
then click “Connect” button. After connecting successfully, you can see device information in the
lower-left corner, as below picture shows.
2. Configuration of Device Connection on Initial Page
Below picture shows you the connected status.
How to connect?
1). Add Device
Click the device under “Config DeviceList”
and drag it to the middle area, then release
mouse, the device will be added to this
area,
2). Delete Device
Right-click the device, select “Delete
Module” to delete it.
3). Configuration of Device ID
Right-click the device, select “Change DeviceID” , a dialog appears as below picture shows,input
a new Device ID in the text field, then click “OK” button to change
it.
After successfully connected devices, double click DLM808 on this
initial page to enter DSP control page, which will be introduced
later.
9
6
DSP Control
3. Input DSP Channel
1
3
2
5
6
7
8
9
1). Device Data
After connecting PC with DLM808 and communication right, here you can see information about current
channel, device name, ID number etc. If Connect Status icon is green, means communication is right; While
off means communication is fault.
4
10
10
2). Expander/Gate
In this area, you can adjust parameter of EXP/Gate , the curve in coordinate will change with parameter’s
change.
The Expander is used for adding input dynamic range according to user’s demand.
- Threshold
Click the control to set Gate threshold of selected channel. This threshold value determines the open level of
Gate. Actually, all input audio signal that higher than threshold value can go through, the range of threshold
value is -64dB to 20dB.
If input signal is lower than threshold, the Expander can enlarge it with setting ratio, then output the signal.
If input signal is larger than threshold, output signal will be the same with input signal, which means ratio
is 1:1.
If adjusting the ratio to max(∞), Expander will change to noise Gate.
- Ratio
Click the control to set ratio of input signal to output signal. That is the dynamic change value of Expander’s
input signal/dynamic change value of Expander’s output signal.
- Attack
Click the control to set the interval time from selected channel’s signal beyond threshold to open noise Gate,
the time can be set from 10 to 150ms.
Signals that increase slowly need lower attack, because if set the attack value too high, it may cause “click”
noise. Actually, all Gate may cause “click” noise when operation, but it can be avoid if set properly.
DSP Control
- Release
Click the control to set the amount of time for the gate to go from open to fully close. It can be set from
0.01 to 1 second.
Note: A fast release abruptly cuts off the sound once it has fallen below the threshold, A slower release
smoothly changes from open to closed, much like a slow fade out. If the release time is too short, a click can
be heard when re-open the gate .
- Bypass
Click Bypass, it will illuminate red, all input signals will bypass control of Threshold, Ratio, Attack and Release
to flow to next block, these parameters can not be adjusted.
- Flat EXP
Click this button to flat all set parameters to be default.
- Polarity
Click this button to invert the phase of the selected channel's signal (to alter the phase by 180°). If the phase
reverse is active the button will illuminate. The Polarity control can be used to correct audio signals which
are out of phase as well as to cancel/reinforce each other.
3). Equalizer
In this area, you can adjust parameter of Equalizer(EQ) , the curve in coordinate will change with
parameter’s change. EQ can compensate and correct frequency characteristic, through which to make its
frequency response characteristic curve to be more smooth and straight. On DLM808, you can adjust 8 band
EQ.
6
- High Pass Filter
This is a high-pass filter. It can pass higher frequencies. When set to its lowest position, the filter is off.
Type indicates the filter’s type that you selected, different type means different shape and different filter
frequency range.
- Low Pass Filter
This is a low-pass filter. It can pass lower frequencies. When set to its highest position, the filter is off.
Type indicates the filter’s type that you selected, different type means different shape and different filter
frequency range.
- EQ Frequency
Click the control to set the center frequency of the equalizer's
Low/Low-mid/High-mid/ High band separately. The center frequency is the middle of the pass-band between
the lower and upper cutoff frequencies which define the limits of the band. The center frequency can be set
from 20Hz to 20K Hz.
- Q
Click the control to set the Q for the Low/Low-mid/High-mid/High band separately. The Q is the ratio of the
center frequency to the bandwidth. If the center frequency is constant, the bandwidth is inversely
proportional to the Q, which means that if you raise the Q, the bandwidth will be narrowed. It can be
adjusted from 0.4 to 24.
- Gain
Click the control to set the gain attenuation or boost at the center frequency for the
Low/Low-mid/High-mid/High band separately. It can be set from -24 to +24 dB. When Gain is 0dB, center
frequency and Q are all invalid.
- Type
To select current filter type of current EQ, option is Peak/L.Shelf/H.Shelf.
- EQ Bypass
Click this button to bypass all signal to next block, if EQ bypass function is active the button will illuminate.
If it is not active,signal will be processed at this block and then flow to next block.
- Flat EQ
To flat all setting parameters to default.
11
6
DSP Control
4). Compressor
In this area, you can adjust parameter of compressor. Compressor will compress signal that higher than
threshold with specified ratio, then output it. The curve in coordinate will change with parameter’s change.
-Threshold
Click the control to set the compressor threshold for selected channel.
If amplitude of an audio signal exceeds a certain threshold, the compressor will reduce the level of this signal
with specified ratio;
If amplitude of an audio signal is lower than this given threshold, compressor won’t work, signal will flow
to next block directly.
If setting ratio to “+∞”, compressor will be limited.
Threshold can be set from -30dB to 20dB.
- Ratio
Click the control to set the compression ratio for selected channel. The ratio determines the amount of gain
reduction. For example, a ratio of 4:1 means that if input level is 4 dB over the threshold, the output signal
level will be 1 dB over the threshold. The ratio can be set from 10:1 to 1:1 until limit.
- Attack
Click the control to set the compressor's attack setting for selected channel. The attack setting is the period
when the compressor is decreasing gain to reach the level that is determined by the ratio. You can set the
attack from 10 to 150 milliseconds.
- Release
Click the control to set the compressor for selected channel. Release sets the length of time the compressor
takes to return to its normal gain once the signal level drops below the threshold. Release can be set from
10 to 1,000 milliseconds.
- Bypass
Click this button to bypass all signal to next block, if compressor bypass function is active the button will
illuminate. If it is not active,signal will be processed at this block and then flow to next block.
- Flat COM
To flat all setting parameters to default.
- Delay
Delay here can engage and disengage the delay function for selected Channel. Move the slide below it to set
delay time. Only if delay function is active can set the delay time. If Bypass beside it is enable, the parameter
can not be adjusted.
5). Current input channel selection
Click channel button 1-8, corresponding background LED will light, which means current channel is selected,
you can set parameters on this channel.
6). Input channel mute control
Click it, the background LED will light, which means it enable mute function on current channel.
7). Input channel Meter control
Select the block and slide it to adjust current channel’s volume.
8). Input channel Meter dynamically indication
Dynamically indicate current channel’s input level meter.
9). Input channel Meter value display
The value will vary with slide moving.
12
10). Output channel control
Function in this area is similar to that to input channel. Please read carefully about input channel
introduction.
DSP Control
4. MATRIX
6
1
2
1). Assign of input and output channels
In this area, there are many small blocks, click one block, its background turns green, audio signal
flow from left input channel to top output channel; while the signal won’t go through any
channel if it is not active. Below figure gives an example:
a. Click the block as a marked, its
background turns green, means that
signal input from channel Local 02 will
be assigned to output channel Local
02. But the input channel Local 02
wouldn’t be assigned to other output
channels because there is no other
block activates.
b&c. Click the block as b&c marked,
their background turn green, means
that signal input from channel Local
03 and Local 04 will be assigned to
output channel Local 03. Other
channels that inactive won’t be assigned to any other output channel.
d&e. Click the block as d&e marked, their background turn green, means corresponding input
channel signal will be assigned to corresponding output channel.
And so on...
3
a
c
b
d
e
13
6
DSP Control
2). Input Channel Parameter Control
Please refer to section 3 Input DSP Channel for details about this area.
3). Output Channel Parameter Control
Please refer to section 3 Input DSP Channel for details about this area.
5. Output DSP Channel
14
As you can see, compared with input DSP channel, this page only remove the Gate/EXP function,
please refer to section 3 Input DSP Channel for details about its function.
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.