TOPP C160, C160RWA Installation And User Instructions Manual

INSTALLATION AND USE INSTRUCTIONS
BEFORE INSTALLING AND USING THE ACTUATOR, IT IS
COMPULSORY FOR THE INSTALLER AND THE USER TO READ
AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.
CHAIN ACTUATOR FOR WINDOW AUTOMATION
C160
VER.0.0 REV.07.18
original instructions
THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR
AND MUST BE PRESERVED FOR FUTURE REFERENCE
UNTIL DEMOLITION OF THE SAME.
C160RWA
C160
3
INDICE
ISTRUZIONI PER L’INSTALLAZIONE E L’USO
C160
3
INDEX
INSTALLATION AND USE INSTRUCTIONS
C160
1- EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINE..pag.04 2- GENERAL REMARKS
2.1- General Instructions ..............................................................................................pag.05
2.2- Installer and user....................................................................................................pag.05
2.3- Technical assistance..............................................................................................pag.05
2.4- Reserved rights ....................................................................................................pag.05
2.5- Description of personnel .......................................................................................pag.05
3- TECHNICAL DESCRIPTION
3.1- Actuator Denomination - Dimensions - Technical data..........................................pag.06
3.2- Formulas for the calculation of thrust and tractive force........................................pag.08
3.3- Destination of use..................................................................................................pag.08
3.4- Use limits................................................................................................................pag.08
3.5- Rating plate and “CE” marking .............................................................................pag.08
3.6- Package ................................................................................................................pag.09
3.7- Components and dimensioning..............................................................................pag.11
3.8- Application..............................................................................................................pag.12
4- SAFETY
4.1- General Instructions ..............................................................................................pag.13
4.2- Safety devices ......................................................................................................pag.14
4.2.1- Protection against electric hazard ......................................................................pag.14
4.3- Safety plates..........................................................................................................pag.14
4.4- Residual risks ........................................................................................................pag.14
5- INSTALLATION
5.1- General Instructions...............................................................................................pag.15
5.2- Installation .............................................................................................................pag.15
5.3- Electric connections...............................................................................................pag.15
5.4- Command devices.................................................................................................pag.15
5.5- Correct assembly of the actuator on the window frame.........................................pag.16
5.6- Emergency procedures..........................................................................................pag.17
6- USE AND OPERATION
6.1- Use of the actuator ................................................................................................pag.18
7- MAINTENANCE
7.1- General Instructions ..............................................................................................pag.18
8- DEMOLITION
8.1- General Instructions ..............................................................................................pag.19
9- SPARE PARTS AND ACCESSORIES UPON REQUEST
9.1- General Instructions...............................................................................................pag.19
10- DRAWINGS / INSTALLATION INSTRUCTIONS
10.1- Frame actuator mounting...........................................................................pag.20
10.2- Casement actuator mounting........................................................................pag.49
11.ELECTRICAL WIRING DIAGRAM............................................................pag.54
4
1- EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY
INSTALLATION AND USE INSTRUCTIONS
ORIGINAL
The undersigned, in the name of and behalf of the following company
Topp S.r.l. Via Galvani, 59 36066 Sandrigo (VI) Italia
herewith declares that the person authorised to compile the technical file is Name: Bettiati Roberto - Topp S.r.l. Address: via Galvani,59 36066 Sandrigo (VI)
and that to the partly completed machinery
CHAIN ACTUATOR FOR WINDOW AUTOMATION
RWA CHAIN ACTUATOR FOR WINDOW AUTOMATION
Type: C160 Model: C160/230V - C160/24V RWA - C160/24V Double push point RWA
the following essential requisites of the
2006/42/EC Machinery Directive (including all applicable amendments)
have been applied and fulfilled: Enclosure I: 1.5.1; 1.5.2; 1.5.10; 1.5.11 that the relevant technical documentation is compiled in accordance with part B of Annex VII of the above mentioned Machinery Directive..
The above identified partly completed machinery is also in conformity with the all the relevant provisions of the following directives (including all applicable amendments)
EMC Directive 2014/30/EU
RoHS II Directive 2011/65/EU
The following harmonised standards have been applied:
EN 60335-2-103:2015 (applicable parts)
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 61000-6-2:2005.
EN 61000-6-3:2007 + A1:2011 + AC:2012.
EN 50581:2012
EN 12101-2:2003 (only for RWA): - 7.1 Dual purpose ventilator class "RE1000" -7.2 class "SL 0" - 7.3
class"T(-15)" - 7.4 class "WL1500" - 7.5 class "B300".
and the following technical documents:
EN 62233:2008
The undersigned also undertakes the obligation, in response to a duly reasoned request by the national market surveillance authorities, to transmit to the a.m. authorities, in electronic or paper format, the relevant technical documentation on the partly completed machinery. The above identified partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of the above mentioned Machinery Directive. This declaration of conformity is issued under the sole responsibility of the manufacturer.
Date: Sandrigo01/02/2018 Signature: Matteo Cavalcante
Amministratore ................................................................
5
GENERAL REMARKS -2
INSTALLATION AND USE INSTRUCTIONS
C160
2.1- GENERAL INSTRUCTIONS
BEFORE INSTALLING AND USING THE ACTUATOR, IT IS COMPULSORY THAT THE INSTALLER AND THE USER CAREFULLY READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS.
THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR AND MUST COMPULSORILY BE PRESERVED FOR FUTURE REFERENCE.
THE MANUFACTURER HAS NO LIABILITY FOR ANY EVENTUAL DAMAGE TO PERSONS, ANIMALS AND THINGS DUE TO THE INOBSERVANCE OF THE PRESCRIPTIONS DESCRIBED IN THIS MANUAL.
IN ORDER FOR THE AUTOMATION UNIT TO OPERATE CORRECTLY, WE RECOMMEND CARRYING OUT PERIODICAL MAINTENANCE ON IT, AS INDICATED IN PAR. 7 OF THIS MANUAL.
THE WARRANTY ON THE ACTUATOR WILL NOT BE HONORED IF PRODUCT IS NOT INSTALLED AND USED ACCORDING TO THE INSTRUCTIONS PROVIDED AND THE REGULATIONS SHOWN IN THIS INSTRUCTION MANUAL AND IF IT IS USED WITH NONGENUINE PARTS, ACCESSORIES, SPARE PARTS AND/OR CONTROL/FEEDING UNITS.
2.2- INSTALLER AND USER
THE ACTUATOR INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION.
THE INSTALLATION TECHNICIAN SHALL ACCEPT FULL RESPONSIBILITY FOR ANY INSTALLATION ERRORS AND FOR ANY FAILURE TO ADHERE TO THE INSTRUCTIONS PROVIDED IN THIS MANUAL. THE INSTALLATION TECHNICIAN SHALL THEREFORE BE EXCLUSIVELY LIABLE FOR ANY DAMAGES CAUSED TO USERS AND/OR THIRD PARTIES THAT MAY ARISE AS A RESULT OF INCORRECT INSTALLATION.
THE ACTUATOR CAN BE USED EXCLUSIVELY BY A USER ACTING IN COMPLIANCE WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL AND/OR IN THE MANUAL OF THE ACTUATOR CONTROL DEVICE (E.G.: CONTROL UNIT).
2.3- TECHNICAL ASSISTANCE
Contact the installation technician or retailer for assistance.
2.4- RESERVED RIGHTS
The reserved rights on this manual "Installation and use instructions" remain property of the Manufacturer. Each information herein contained (text, drawings, diagrams, etc.) is reserved.
None part of this manual can be reproduced and disclosed (totally or partially) by any reproduction means (photocopies, microfilms or other) without written authorization of the Manufacturer.
2.5-DESCRIPTION OF PERSONNEL
USERS M UST NEVER P ERFORM OP ERATIONS R ESERVED F OR MAINTENANC E PEOP LE OR S PECI ALISED TECHNICIANS. THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGE DERIVING FROM FAILURE TO OBSERVE THE ABOVE REQUIREMENTS.
Specialised electrician:
A specialised electrician must be able to install the actuator, start it and operate it both in normal conditions and in the maintenance mode; he/she is qualified to perform all electrical and mechanical adjustment and maintenance operations. He/she is allowed to work on live electrical cabinets and junction boxes.
User:
specialised person capable of operating the actuator under normal conditions by using the relative controls. He/she must also be able to operate with the actuator under “maintenance” in order to perform simple routine maintenance operations (cleaning), and start or reset the actuator following an unscheduled stop.
6
3- TECHNICAL DESCRIPTION
INSTALLATION AND USE INSTRUCTIONS
C160
3.1- DENOMINATION – DIMENSIONS TECHNICAL DATA
C160 stroke 360 230V - 24V
C160 stroke 600 230V - 24V
385
W
H
192.8
W
H
494
202.5
634
W
H
C160 stroke 1000 24V
202.5
C160 stroke 1000 230V
H = 43 mm W= 68.5 mm
360 600 1000
0,43 A 0,60 A 0,60 A
11 W 15 W 15 W
300 N Fig.A 50 N 200 N 200 N 200N
7,74 10 mm/s 10 mm/s
46,5 s 60s 100s
1,7 kg 1,9 kg 2,5 kg
322 562 962
Stroke (1 ) (m m)
from - 5°C to + 50°C
Electronic fo r opening-by
ampero metric absorptio n fo r
clo sing
IP30
yes
4 min
24V
Class III
Operating temperature
TECHNICAL DATA
C160 RWA 24V Single push point
Efective stro ke botto m hung inward
Type of service S (3)
Protectio n degree of electric devices
Parallel electric connection of more actuato rs on the same windo w
Thrust fo rce
Tractive force
Idle trans latio n speed
Duration of the idle st ro ke (2)
Power supply vo ltage
Abso rbed current
Abso rbed power with load
Protectio n against electric shock
Limit switch
Gross weight
W
H
740
307
(2 ) It is co nsidered RWA if the Duratio n of the idl e stro ke is less than or equal to 6 0 s / 6 00 mm Equivalent str oke
(3 ) Service of limit ed durat io n accordi ng to EN 60 034
(1) To lerance on the pr ecision o f li mit swi tch t rip ping at o utp ut: +/- 10mm
360 600 1000
0,12A 0,14A 0,14A
28W 22,5W 22,5W
300 Fig.A 50 200 200 185
8mm/s 8mm/s 8mm/s
45s 75s 125s
1,7 kg 1,9 kg 2,8 kg
322 562 962
TECHNICAL DATA
C160 230V Single push point
Power supply vo ltage
Abso rbed current
Abso rbed po wer with load
Protec tio n against elect ric sho ck
Stroke (1) (m m )
from - 5°C to + 50°C
Electro nic fo r opening-by
ampero m etric abso rptio n fo r
clo sing
IP30
yes
4 min
230V ~ 50Hz
Class II
Duratio n of the idle stro ke
Efectiv e stro ke bott o m hung inward
Gross weight
Operating tem perature
Limit switch Type of servic e S (3)
Protec tio n degree of elect ric devic es
Parallel electric co nnect io n of mo re actuato rs on the same window
Thrust fo rce
Tractiv e fo rce
Idle trans latio n speed
Stroke [mm]
Thrust load actuator [N]
Fig. A
7
INSTALLATION AND USE INSTRUCTIONS
C160
Lt
L
W
H
TECHNICAL DESCRIPTION -3
C160 Double push point stroke 360 24V
H = 43 mm W= 68.5 mm
Lt; L : variables
(2 ) It is co nsidered RWA if the Duratio n of the idl e stro ke is less than or equal to 6 0 s / 6 00 mm Equivalent str oke
(3 ) Service of limit ed durat io n accordi ng to EN 60 034
(1) To lerance on the pr ecision o f li mit swi tch t rip ping at o utp ut: +/- 10mm
Stroke (1 ) (m m)
360
24V
0,75A
18W
Class III
IP30
yes
400 300
7,5mm/s
48s
4 min
Electronic fo r o pening-by
ampero metric abso rptio n
fo r clo sing
from - 5°C to + 50°C
3,9kg - 7,0 kg
1200<Lt<3000 2
3000<Lt<4000
3
322
Protectio n degree of elect ric devic es
Parallel electric co nnect io n of mo re actuato rs on the sam e window
TECHNICAL DATA
C160 RWA 24V Double push point
Power supply vo ltage
Abso rbed current
Abso rbed power with load
Protectio n against elect ric sho ck
Thrust fo rce
Tractive force
Idle trans latio n speed
Duration of the idle stro ke (2)
Gross weight
Limit switch
Operating temperature
Type of service S (3)
Number of clamps
Efective stro k e bot to m hung inward
3.4- USE LIMITS
The actuator has been designed and manufactured exclusively for the destination of use given in par. 3.3, therefore, any other type of use is strictly forbidden in order to assure in any moment the safety of the installer and of the user, as well as the efficiency of the actuator itself. Check carefully all environmental conditions (temperature, humidity, wind, snow, potential chemical agents, etc.) and installation settings (misaligned fitting of brackets and attachment to the frame, frictions produced by hinges or gaskets, use of selfbalancing window stays, etc.) it is recommended that they not exceed the actuator performances shown in par.3.1. If they do, please find an alternative and more suitable product for your application.
IT IS STRICTLY FORBIDDEN TO INSTALL THE ACTUATOR ON THE EXTERNAL SIDE OF THE WINDOW FRAME SUBJECT TO ATMOSPHERIC AGENTS (RAIN, SNOW, ETC.).
THE USE OF THE ACTUATOR IN ENVIRONMENTS WITH POTENTIALLY EXPLOSIVE ATMOSPHERE IS STRICTLY FORBIDDEN.
IT IS COMPULSORY TO KEEP THE PACKAGE AND THE ACTUATOR OUT OF REACH OF CHILDREN.
3.3- DESTINATION OF USE
The actuator has been designed and manufactured to perform, by means of a command device, the opening and closing of top hinged windows, bottom hinged windows and side hinged windows. Application RWA: The RWA actuator has been designed and manufactured to perform in case of emergency the opening of the window for safe discharge of the smoke. It must be installed in windows that opening outside and bottom hinged. According to EN 12101-2 / 2003.
3.4- FORMULAS FOR THE CALCULATION OF THRUST AND TRACTIVE FORCE
Top hung windows (A) or bottom hung windows (B)
F= Force necessary for opening or closing P= Weight of the window (Only movable part) C= Window opening stroke H= Window height (Only movable part)
F = (0,54 x P) x ( )
C H
P
F
H
C
B
P
F
H
C
A
Fig. 1
8
3- TECHNICAL DESCRIPTION
INSTALLATION AND USE INSTRUCTIONS
C160
EX
3.5- RATING PLATE AND “CE” MARKING
The “CE” marking certifies the compliance of the machine with the essential safety and health requirements foreseen by the product European Directives. The rating plate is an adhesive plate in polyester, silk-screen printed in black, having the following size: L=24 mm - H=60 mm It is applied externally on the actuator. The plate bears in readable and indelible way the following data:
• logo and address of the manufacturer
• type and model
• voltage and intensity of power supply (V - A)
• absorbed electric power P (W)
• thrust and tractive force F (N)
•type of service S2 (min)
• idle translation speed (mm/s)
• protection degree (IP)
• “CE” marking
• symbol of WEEE Directive 2002/96/CE
• symbol of double insulation (only for mod. C160/230V)
• serial number
3.6- PACKAGE
Each package of the product (Fig. 2) contains:
1) Actuator equipped with power supply (Ref. A);
2) Window mounting brackets (depending on application) and screws for aluminum (Ref. B);
3) Actuator brackets (depending on application) and screws for aluminum (Ref. C);
4) Installation and use instructions (Ref.D);
5) Safety plate (Ref. E).
MAKE SURE THAT THE ABOVE DESCRIBED COMPONENTS ARE CONTAINED IN THE PACKAGE, AS WELL AS THAT THE ACTUATOR HAS NOT BEEN DAMAGED DURING TRANSPORT.
SHOULD ANY ANOMALY BE DETECTED, IT IS FORBIDDEN TO INSTALL THE ACTUATOR, AND IT IS COMPULSORY TO REQUIRE TECHNICAL ASSISTANCE FROM YOUR DEALER OR THE MANUFACTURER.
THE PACKAGING (PAPER, PLASTIC, ETC.) HAS TO BE DISPOSED ACCORDING TO THE LAWS IN FORCE.
9
INSTALLATION AND USE INSTRUCTIONS
C160
TECHNICAL DESCRIPTION -3
10
3- TECHNICAL DESCRIPTION
INSTALLATION AND USE INSTRUCTIONS
C160
M
AC
C
H
I
N
A
AD
A
V
V
I
A
ME
N
TO
A
UTO
M
A
T
I
CO
A
UTOMA
T
I
C
M
A
C
H
I
N
E
P
R
IM
A
DI
IN
S
T
A
L
LA
R
E E
UT
I
L
I
ZZA
R
E
L'
A
TT
UA
TO
R
E
È
O
B
B
L
I
GATO
R
I
O
C
HE
L'INS
T
A
LL
ATO
R
E E L'
U
T
I
L
IZ
Z
ATO
RE
L
E
G
GA
N
O E
C
O
M
P
R
E
N
D
ANO
I
N T
U
T
T
E
LE S
U
E P
A
R
T
I I
L M
A
N
U
A
L
E
T
H
E
I
N
S
T
A
L
L
E
R
A
N
D
U
S
E
R
M
U
ST
R
E
AD
A
N
D U
N
D
E
R
S
T
AN
D
A
L
L
PARTS
O
F T
HI
S
M
A
N
U
AL
B
EF
O
R
E
I
N
S
T
A
L
L
I
N
G
AN
D
U
S
IN
G
T
H
E
A
CT
U
ATO
R
.
P
E
RI
C
OLO
A
T
T
E
N
Z
I
O
N
E
AL
LE M
A
N
I
B
EWAR
E
O
F
YO
U
R H
A
N
D
S
A
T
T
E
N
Z
I
ON
E
MAC
C
H
I
N
A AD
A
VVI
A
ME
N
TO
A
UTOM
A
T
I
C
O
CO
N C
O
M
A
N
D
O
A
D
I
S
T
A
N
Z
A
AT
TE
NT
I
O
N
!
A
U
TOM
A
T
I
C
M
AC
H
I
N
E
W
I
T
H
RE
M
O
T
E
C
O
NT
R
O
L
D
E
V
I
C
E
IT
EN
SB
S3S3
A
S4
SC
SD
SE
SF
M1
M2
SG
S1
P1
S2
Ref.
C
Ref.
B
Ref.
A
Ref.
D
Ref.
E
Fig.
2
SA
V1
V2
V3
V4
VA
VB
VC
VD
VE
VF
VG
ISTRUZIONI P ER L’INSTALL AZIONE E L’US O
PRIMA DI INSTALLARE E UTILIZZARE L’ATTUATORE È OBBLIGATORIO CHE
L’INSTALLATORE E L’UTILIZZATORE LEGGANO E COMPRENDANO
IN TUTTE LE SUE PARTI IL PRESENTE MANUALE.
ATTUATORE A CATENA
PER AUTOMAZ IONE FINE STRE
C160
COD. 0P5295
VER.0.0 REV.03.17
istruzioni originali
IL PRESENTE MANUALE È PARTE INTEGRANTE DELL’ATTUATORE E DEVE
OBBLIGATORIAMENTE ESSERE CONSERVATO
PER FUTURI RIFERIMENTI FINO ALLA DEMOLIZIONE DELLO STESSO.
C160RWA
C160
AF TC Ø4.8x16
AF TC Ø4.2x19
AF TC Ø4.2x19
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
AF TC Ø4.8x16
11
INSTALLATION AND USE INSTRUCTIONS
C160
TECHNICAL DESCRIPTION -3
3.7- COMPONENTS AND DIMENSIONING
S1
S2
S4
SC
SD
SE
M1
M2
Fig.
3
30
18
26.5
44.5
32.9
50
40
21.4
29
26.9 40
40.7 50
21.4
29
35.7
38
32
95
17.5
18.5
32
38
18.5
95
17.5
24.5
5
6
SA
S3
19
12
13
13
23
23
24
34.1
2.5
9.6
11.6
5.6
118.97
108.5
23
23
SA
16
21
34.5
64
75
SB
30
R2.75
15
6.25
2
13
13
77.5
2.5
18
26.5
44.5
59.5
SF
18
26.5
44.5
59.5
46
25
26
46
57
SG
30
26,5 44,5
18
3030
12
3- TECHNICAL DESCRIPTION
INSTALLATION AND USE INSTRUCTIONS
C160
APPLICATION
REF.
Single
push point
Double
push point
TOP HUNG Outward opening
SA,S1 SA,S2
A1_1
TOP HUNG Outward opening
SC,S1,M1
A1_2
TOP HUNG Outward opening
SD,S1,M1
A1_3
TOP HUNG Outward opening
SE,S1,M1
A1_4
BOTTOM HUNG
Outward opening
SA,S1 SA,S2 SF,S1,M1
A2
BOTTOM HUNG Inward opening
SB,S3 SG,S3,M2
A3
SIDE HUNG Outward opening LH
SA,S2 SF,S1,M1
A4_1
SIDE HUNG Outward opening RH
SA,S4 SF,S1,M1
A4_2
3.8- APPLICATION
ACTUATOR MOUNTING ON THE FRAME
Pag. 20
Pag. 34
Pag. 34
Pag. 34
Pag. 23, 38
Pag. 26, 40
Pag. 28, 43
Pag. 28, 43
Minimun window frame height
mm (1)
stroke mm
360
600
1000
500
600
Sing.
700
Doub.
400
Doub.
500
Doub.
500
600
1000
Sing.
400
Doub.
500
800
1000
Sing.
900
Doub.
500
600
1000
Sing.
700
Doub.
500
600
1000
Sing.
700
Doub.
Push point
Fig.
4
4.1- GENERAL INSTRUCTIONS
OPER ATORS MUST BE I NFORMED OF ACCIDENT RISKS, SAFETY DEVICES AND THE GENERAL ACCIDENT PREVENTION REGULATIONS ESTABLISHED BY INTERNATIONAL DIRECTIVES AND BY THE LAW IN FORCE IN THE COUNTRY OF USE. ALL OPERATORS MUST STRICTLY COMPLY WITH THE ACCIDENT PREVENTION REGULATIONS IN FORCE IN THE COUNTRY OF USE.
DO NOT REMOVE OR ALTER THE PLATES PLACED ON THE ACTUATOR BY THE MANUFACTURER.
IF THE WINDOW FRAME IS ACCESSIBLE FROM OR INSTALLED AT A HEIGHT OF LESS THAN 2.5 m FROM THE GROUND, AND IF IT CAN BE COMMANDED BY AN UNTRAINED USER OR WITH A REMOTE CONTROL DEVICE, FIT AN EMERGENCY STOP SYSTEM WHICH AUTOMATICALLY CUTS IN TO PREVENT THE RISK OF CRUSHING OR DRAGGING PARTS OF THE BODY INSERTED BETWEEN THE MOVING AND FIXED PARTS OF THE WINDOW FRAME.
ANY TAMPERING WITH OR UNAUTHORISED REPLACEMENT OF ONE OR MORE PARTS OR COMPONENTS OF THE ACTUATOR, OR THE USE OF UNORIGINAL ACCESSORIES AND CONSUMABLES, MAY INCREASE THE RISK OF ACCIDENT AND THUS RELIEVES THE MANUFACTURER OF ALL CIVIL AND PENAL LIABILITY.
13
INSTALLATION AND USE INSTRUCTIONS
C160
TECHNICAL DESCRIPTION -3
C160
SAFETY -4
APPLICATION
REF.
Single
push point
Double
push point
SIDE HUNG Inward opening LH
SB,S3 SG,S3,M2
A5_1
SIDE HUNG Inward opening RH
SB,S3 SG,S3,M2
A5_2
On the window Inward opening
SA,S1 SA,S4
B1
On the window
Inward opening
SC,S1,M1
B1
ACTUATOR MOUNTING
ON MOVABLE WINDOWS
ACTUATOR MOUNTING
ON THE FRAME
Pag. 31, 46
Pag. 49
Pag. 52
Pag. 31, 46
Minimun window frame height
mm (1)
stroke mm
360
600
1000
500
800
1000
Sing.
900
Doub.
Push point
500
800
1000
Sing.
900
Doub.
1100
1900
3000
Sing.
1000
Doub.
(1) Distance from the opening edge of the window to the axis of rotation of the window.
Fig.
4
THE MAINTENANCE OPERATIONS INVOLVING THE TOTAL OR PARTIAL DISMOUNTING OF THE ACTUATOR MAY ONLY
BE PERFORMED AFTER DISCONNECTING IT FROM THE POWER SUPPLY.
THIS APPLIANCE MAY NOT BE USED BY PERSONS (CHILDREN INCLUDED) WITH REDUCED PHYSICAL, SENSORIAL OR MENTAL CAPACITIES, OR INEXPERT PEOPLE, UNLESS THEY ARE SUPERVISED AND TAUGHT HOW TO USE IT BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN MUST BE CONTROLLED TO MAKE SURE THEY DO NOT PLAY WITH THE APPLIANCE.
DURING HANDLING AND INSTALLATION OF THE PARTS, THE PERSONNEL SHALL BE EQUIPPED WITH SUITABLE PERSONAL PROTECTION EQUIPMENT (PPE) SO AS TO PERFORM THE WORKS REQUIRED UNDER SAFE CONDITIONS.
14
4- SAFETY
INSTALLATION AND USE INSTRUCTIONS
C160
MACCH INA AD AVVIAMEN TO AUTOMATICO
AUTOM ATIC M ACHINE
PRIMA D I INSTALLAR E E UTILIZZ ARE L'ATTUATORE È OBBLIGATORI O CHE L'INSTAL LATORE E L'UTIL IZZATORE LEG GANO E COMP RENDANO IN TUTTE L E SUE PARTI I L MANUALE
THE IN STALLER AND U SER MUST R EAD AND UN DERSTAND ALL PART S OF THIS M ANUAL BEF ORE INSTALL ING AND USI NG THE ACTU ATOR.
PERIC OLO ATTENZIO NE ALLE MAN I
BEWARE OF YOUR HAN DS
ATTENZI ONE MACCHINA AD AVVIAMENTO AUTOMATICO CON COMANDO A DISTAN ZA
ATTENTI ON! AUTOMATI C MACHI NE WITH REMO TE CONT ROL DEVI CE
IT
EN
Fig.
5
4.3- SAFETY PLATES
IT IS FORBIDDEN TO REMOVE, MOVE, SPOIL OR IN ANYWAY REDUCE THE VISIBILITY OF THE SAFETY PLATES. FAILURE TO OBSERVE THE ABOVE MAY CAUSE SERIOUS HARM TO PEOPLE AND DAMAGE TO PROPERTY. THE MANUFACTURER DECLINES ALL LIABILITY FOR ANY DAMAGE CAUSED BY THE FAILURE TO OBSERVE THE ABOVE REQUIREMENT.
In Fig. 5 illustrates the safety plate: this must applied directly to the outside of the actuator or near it and always in a position where it can be seen by the installer and/or operator.
4.4- RESIDUAL RISKS
The installer and the user are herewith informed that after the actuator has been installed on the window, the actuator drive can accidentally generate the following residual risk:
Residual risk: Hazard of squashing or dragging of body parts inserted between the movable and the fix part of the window frame.
Exposure frequency: Accidental and when the installer or the user decides to perform a wrong voluntary action. Severity of the damage: Light lesions (usually reversible) Adopted measures: Before enabling the device, it is compulsory to verify that near the window there are not persons,
animals or things whose safety may be accidentally jeopardized. During actuator operation, it is compulsory to be in a safe control position assuring visual control on the window movement.
4.2- SAFETY DEVICES
4.2.1- PROTECTION AGAINST ELECTRIC HAZARD
The actuator is protected against electric hazard due to direct and indirect contacts. The protection measures against direct contacts aim at protecting people against hazards due to contact with active parts, usually live parts; while the protection measures against indirect contacts aim at protecting people against hazards due to conducing part, which are usually insulated, but could become live in case of failure (insulation failure). The adopted protection measures are the following:
1) Insulation of live parts by means of a plastic material body;
2) Enclosure with suitable protection degree;
3)Only for Mod. C160/230 V equipped with double insulation: Protection of passive type given by the use of components
with double insulation, also called components of class II or with equivalent insulation. (It is forbidden to connect the actuators equipped with double insulation to the earth plant.
15
INSTALLATION AND USE INSTRUCTIONS
C160
INSTALLATION -5
5.1- GENERAL INSTRUCTIONS
THE ACTUATOR INSTALLATION CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL SATISFYING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORE SEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION.
THE ACTUATOR PERFORMANCE MUST BE SUFFICIENT TO ASSURE THE CORRECT MOVEMENT OF THE WINDOW. IT IS COMPULSORY TO VERIFY THE THRUST OR TRACTIVE FORCE ACCORDING TO THE TYPE AND WEIGHT OF THE WINDOW (PAR. 3.1). IT IS FORBIDDEN TO EXCEED THE LIMITS CONCERNING TECHNICAL DATA (PAR. 3.1).
THE ACTUATOR INSTALLATION MUST BE PERFORMED EXCLUSIVELY WITH CLOSED WINDOW.
BEFORE PERFORMING THE INSTALLATION OF THE ACTUATOR ON BOTTOM HUNG WINDOWS, VERIFY THAT ON BOTH SIDES OF THE WINDOW TWO COMPASS STROKE LIMIT DEVICES ARE INSTALLED IN ORDER TO AVOID THE ACCIDENTAL FALL OF THE WINDOW.
FOR CORRECT OPERATION OF THE ACTUATOR, THE WINDOW FRAME MUST HAVE A MINIMUM HEIGHT VALUE INCLUDED IN THE RANGE STATED IN PAR 3.8.
VERIFY THAT DISTANCE “D” BETWEEN THE ACTUATOR SHELL AND THE CHAIN END IS GREATER THAN 5 mm.
THE FITTING SURFACE FOR THE BRACKETS MUST BE PERFECTLY FLAT AND/OR SMOOTH.
CHECK THE ADEQUACY OF THE WINDOW AND THE SUITABILITY OF THE MATERIALS OF THE WINDOW AND/OR FRAME ON WHICH THE ACTUATOR WILL BE FASTENED. AND IT MUST ENSURE A GOOD SUPPORT OF THE ACTUATOR­WINDOW ASSEMBLY DURING THE MOVEMENT.
5.3- ELECTRIC CONNECTIONS
THE CONNECTION OF MODEL C160/24V HAS TO BE CARRIED OUT WITH VERY LOW VOLTAGE SAFETY FEEDER PROTECTED AGAINST SHORT CIRCUIT.
THE ELECTRIC CONNECTION OF THE ACTUATOR (PAR.11) CAN BE PERFORMED ONLY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL FORESEEN BY THE LAW IN FORCE IN THE COUNTRY OF INSTALLATION WHO CAN ISSUE TO THE CUSTOMER A DECLARATION OF CONFORMITY FOR THE CONNECTION AND/OR PLANT CARRIED OUT.
BEFORE PERFORMING THE ELECTRIC CONNECTION OF THE ACTUATOR, VERIFY THE CORRECT INSTALLATION ON THE WINDOW
THE MAINS TO WHICH THE ACTUATOR IS CONNECTED MUST COMPLY WITH THE REQUIREMENTS OF THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION, AS WELL AS SATISFY THE TECHNICAL FEATURES GIVEN IN PAR.3.1 AND ON THE RATING PLATE AND THE “CE” MARKING.
THE SECTION OF THE MAINS CABLES MUST BE PROPERLY SIZED ACCORDING TO THE ABSORBED ELECTRIC POWER (SEE RATING PLATE AND “CE” MARKING).
ANY TYPE OF ELECTRIC MATERIAL (PLUG, CABLE, TERMINALS, ETC.) USED FOR THE CONNECTION MUST BE SUITABLE FOR THE USE, WITH “CE” MARKING, AND COMPLYING WITH THE REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION.
TO ASSURE AN EFFICIENT SEPARATION FROM THE MAINS, IT IS COMPULSORY TO INSTALL UPSTREAM OF THE DEVICE A TEMPORARY BIPOLAR SWITCH (PUSHBUTTON) OF APPROVED TYPE. UPSTREAM OF THE COMMAND LINE, IT IS COMPULSORY TO INSTALL AN UNIPOLAR MAIN SWITCH WITH OPENING OF CONTACTS OF AT LEAST 3 mm.
BEFORE MAKING ANY ELECTRICAL CONNECTIONS ON THE ACTUATOR, MAKE SURE THE POWER SUPPLY CABLE IS NOT DAMAGED. IF THE CABLE IS DAMAGED, THEN IT MUST BE REPLACED BY THE MANUFACTURER THROUGH THE TECHNICAL ASSISTANCE SERVICE OR BY TECHNICAL OPERATORS.
5.4- COMMAND DEVICES
THE CONTROL DEVICES USED TO DRIVE THE ACTUATOR MUST ASSURE THE SAFETY CONDITIONS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF USE.
According to the different type of installations, the actuators can be driven by the following control devices:
1) MANUAL PUSH-BUTTON:
Bipolar switch button with central OFF position, with biased-off switch;
5.2- INSTALLATION
Perform the installation as described in Chapter 10 : DRAWINGS / INSTALLATION INSTRUCTIONS.
16
5- INSTALLATION
INSTALLATION AND USE INSTRUCTIONS
C160
2) OPTIONAL: CONTROL AND FEEDING UNIT:
TOPP microprocessor control units (e.g.: Mod. TF, etc.) controlling the single actuator or more than one actuator simultaneously by means of one or more manual pushbuttons, an infrared remote control or a 433 Mhz radio control. To these control units, it is possible to connect rain sensors (RDC - 12V), wind sensor (RW) and brightness sensor.
TO ASSURE A CORRECT OPERATION OF THE ACTUATOR, THE COMMAND AND FEEDING UNITS EVENTUALLY USED HAVE TO PROVIDE POWER SUPPLY TO THE ACTUATOR FOR MAX. 120 sec.
BEFORE OPERATING THE ACTUATOR, THE USER MUST COMPULSORILY VERIFY THAT NEAR AND/OR UNDER THE WINDOW THERE ARE NOT ANY PERSON, ANIMAL AND THING WHOSE SAFETY MAY BE ACCIDENTALLY JEOPARDISED (SEE PAR. 4).
5.5-CORRECT ASSEMBLY OF THE ACTUATOR ON THE WINDOW FRAME
THE CORRECT ADJUSTMENT OF THE WINDOW FRAME CLOSING ASSURES THE LIFE AND THE TIGHTNESS OF THE SEALS, AS WELL AS THE GOOD OPERATION OF THE ACTUATOR.
1) With open window frame, verify that the stroke is some centimetre lower than the stroke limited by window frame
mechanical limit devices;
VERIFY THAT THE CHAIN COUPLING (A) IS ON THE SAME AXIS OF THE CHAIN END (B). OTHERWISE, LOOSEN THE TIGHTENING SCREWS AND POSITION CORRECTLY. WHEN THE DEVICES ARE NOT COAXIAL, DAMAGES TO THE ACTUATOR AND THE WINDOW FRAME MAY ARISE (FIG. 6a- 6b).
2) Verify that the two support brackets of the actuator are aligned to each other and the four tightening screws are well
tightened. Between the two brackets and the actuator there must not be any clearance.
Fig.
6a
NO
Fig.
6b
A
B
B
NO
YES
A
YES
17
INSTALLATION AND USE INSTRUCTIONS
C160
INSTALLATION-5
5.6- EMERGENCY PROCEDURES
Should it be necessary to close the window manually, due to power supply failure or mechanism block, follow these instructions:
BEFORE PERFORMING ANY TYPE OF TRIPPING ON THE ACTUATOR AND ON THE WINDOW, IT IS COMPULSORY TO DISCONNECT THE POWER SUPPLY OF THE ACTUATOR AND TO PUT ON “0” THE EVENTUAL SWITCHES OF THE CONTROL DEVICES.
IT IS COMPULSORY TO PADLOCK THE MAIN SWITCH OF THE DISCONNECTION DEVICE INSTALLED ON THE MAINS IN ORDER TO AVOID ANY UNEXPECTED START. IF THE MAIN SWITCH CANNOT BE PADLOCKED, IT IS COMPULSORY TO PLACE A SIGN FORBIDDING THE ENABLING.
EMERGENCY PROCEDURES – For Applications with frame actuator mounting :
Opening S1: Fig. 7- Remove P1 from S1 bracket completely, until the chain end is released.
Opening S2 (S4): Fig. 8- Slacken off both bolts (Ref. 1,2) with a 2.5mm hex wrench, move the square plate aside and extract the actuator (pull out the shorter shaft side first). Opening S3: Fig. 9- Bottom hung – inward opening: with a 3 mm Allen key and 7 mm hex wrench unscrew the nut , remove the pin until the chain end is released.
SHOULD IT BE IMPOSSIBLE TO CARRY OUT THE ABOVE MENTIONED MANOEUVRES, EXTRACT THE ACTUATOR FROM THE BRACKETS PROVIDING CONNECTION TO THE FRAME BY UNSCREWING THE PROPER SCREWS.
EMERGENCY PROCEDURES – For applications with casement actuator mounting:
1) Remove the actuator from the window: For single push point actuator (Fig. 9a): loosen the two screws that secure the actuator to the bracket "SA"; for two push point (Fig. 9b): unfasten the clamps "M1" from the bracket "SC";
2)Move actuator upwards;
3)Open the window just enough and then proceed to pull out the chain terminal from S1 or S4 bracket, described bellow:
Opening S1: Fig. 7- Remove P1 from S1 bracket completely, until the chain end is released.
Opening S4: Fig. 8- Slacken off both frame mount bolts with a 2.5mm hex wrench, move the square plate aside and extract the actuator (pull out the shorter shaft side first).
1
2
S1
Fig.
9
Fig.
8
Fig.
7
S2
S4
S3
P1
Fig.
9a
Fig.
9b
SA
SC
M1
S1
S4
18
6- USE AND OPERATION
INSTALLATION AND USE INSTRUCTIONS
C160
7- MAINTENANCE
6.1- USE OF THE ACTUATOR
THE ACTUATOR CAN BE USED EXCLUSIVELY BY AN USER ACTING IN COMPLIANCE WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL AND/OR IN THE MANUAL OF THE ACTUATOR CONTROL DEVICE (e.g.: WIND AND RAIN CONTROL UNIT).
BEFORE USING THE ACTUATOR, IT IS COMPULSORY FOR THE USER TO READ AND UNDERSTAND IN ALL ITS PARTS THIS MANUAL, AS WELL AS THE EVENTUAL MANUAL OF THE INSTALLED CONTROL DEVICE TYPE.
BEFORE OPERATING THE ACTUATOR, THE USER MUST COMPULSORILY VERIFY THAT NEAR AND/OR UNDER THE WINDOW THERE ARE NOT ANY PERSON, ANIMAL AND THING WHOSE SAFETY MAY BE ACCIDENTALLY JEOPARDISED (SEE PAR. 4).
DURING THE OPERATION OF THE ACTUATOR CONTROL DEVICE, THE USER HAS TO COMPULSORY OCCUPY A SAFE
CONTROL POSITION ASSURING VISUAL CONTROL ON THE WINDOW MOVEMENT.
IT IS COMPULSORY TO VERIFY CONSTANTLY IN TIME THE FUNCTIONAL EFFICIENCY AND THE RATED PERFORMANCE OF THE ACTUATOR, OF THE WINDOW FRAME WHERE IT IS INSTALLED AND OF THE ELECTRIC PLANT, PERFORMING WHEN NECESSARY INTERVENTIONS OF ROUTINE OR SUPPLEMENTARY MAINTENANCE ASSURING OPERATION CONDITIONS COMPLYING WITH SAFETY REGULATIONS.
LL ABOVE MENTIONED INTERVENTIONS CAN BE PERFORMED ONLY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL MEETING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAW IN FORCE IN THE COUNTRY OF INSTALLATION.
IN ORDER FOR THE AUTOMATION UNIT TO OPERATE CORRECTLY, WE RECOMMEND CARRYING OUT PERIODICAL MAINTENANCE ON IT, AS INDICATED IN PAR. 7.1 OF THIS MANUAL.
TOPP INFORMS THE USER THAT, IN ACCORDANCE WITH ART. 8 OF MINISTERIAL DECREE NO. 38 OF 22.1.2008, THE OWNER OF THE SYSTEM IS RESPONSIBLE FOR ADOPTING ALL NECESSARY MEASURES TO MAINTAIN THE SAFETY FEATURES SET OUT IN APPLICABLE LEGISLATION, OBSERVING THE INSTRUCTIONS FOR MAINTENANCE AND USE PROVIDED BY THE MANUFACTURER OF THE DEVICE AND BY THE COMPANY THAT CARRIED OUT THE INSTALLATION.
The use of the actuator allows to control automatically the opening and closing of the window according to the type of control device installed (see par. 5.4).
7.1- GENERAL INSTRUCTIONS
IF THE ACTUATOR WORKS INCORRECTLY, CONTACT THE MANUFACTURER.
ANY WORK ON THE ACTUATOR (E.G.: POWER CABLE, ETC.) OR ITS COMPONENTS MAY ONLY BE CARRIED OUT BY PERSONNEL QUALIFIED BY THE MANUFACTURER. TOPP DECLINES ALL LIABILITY FOR WORK PERFORMED BY UNAUTHORISED PEOPLE.
THE MAINTENANCE OPERATIONS INVOLVING THE TOTAL OR PARTIAL DISMOUNTING OF THE ACTUATOR MAY ONLY BE PERFORMED AFTER DISCONNECTING IT FROM THE POWER SUPPLY.
The actuator incorporates components that do not require significant routine or extraordinary maintenance operations. The recommended maintenance activities should in any case involve the periodical execution (every 6 mounths) of at least the following operations: that the actuator assembly components are clean, the replacement of components that show signs of superficial damage such as injuries, cracks, discoloration, etc., the fixing systems (brackets and screws) are tight, the window frame is not deformed and the seals are tight, and check the cables and connectors.
This maintenance activity may be carried out either by TOPP, in accordance with a specific agreement made with the user, or by the installation technician or by other competent and qualified technical personnel in possession of all legal requirements.
C160
USO E FUNZIONAMENTO -6
C160
DEMOLITION / DISPOSAL -8
USO E FUNZIONAMENTO -6SPARE PARTS AND ACCESSORIES UPON REQUEST -9
19
INSTALLATION AND USE INSTRUCTIONS
8.1-GENERAL INSTRUCTIONS
THE DEMOLITION OF THE ACTUATOR MUST OCCUR IN COMPLIANCE WITH THE LAWS IN FORCE ON ENVIRONMENT PROTECTION.
DIFFERENTIATE THE PARTS MAKING UP THE ACTUATOR ACCORDING TO THEIR DIFFERENT MATERIAL TYPE (PLASTIC, ALUMINIUM, ETC.).
9.1- GENERAL INSTRUCTIONS
THE USE OF “NON-ORIGINAL” SPARE PARTS AND ACCESSORIES WHICH MAY ENDANGER THE SAFETY AND THE
EFFICIENCY OF THE ACTUATOR IS FORBIDDEN..
ORIGINAL SPARE PARTS AND ACCESSORIES HAVE TO BE REQUESTED EXCLUSIVELY TO YOUR DEALER OR TO THE
MANUFACTURER STATING TYPE, MODEL, SERIAL NUMBER, AND YEAR OF CONSTRUCTION OF THE ACTUATOR.
IN CASE OF REPLACEMENT OF THE POWER SUPPLY CABLE, IT IS NECESSARY TO USE A CABLE TYPE HOS-VVF 3 x 0.75
FOR THE C160/230V AND TYPE Si HF Fg4G4 2 x 0.75 FOR THE C160/24V.
THE REPLACEMENT CAN BE PERFORMED EXCLUSIVELY BY COMPETENT AND QUALIFIED TECHNICAL PERSONNEL
MEETING THE PROFESSIONAL AND TECHNICAL REQUIREMENTS FORESEEN BY THE LAWS IN FORCE IN THE COUNTRY OF INSTALLATION.
20
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
Stroke 360
24V - 230V
Standard
Stroke 600
24V - 230V
Standard
A1_1
A1_1
10.1- Actuator mounting on the frame
TOP HUNG Outward opening
TOP HUNG Outward opening
Casement
Frame
Overlap
C
A
B
Casement
Frame
Overlap
C
A
B
SA,S1
SA,S2
24.5
X
L1=184.3
L2=183.7
368
16
SA
S1
392
X
L1=194
L2=283
477
16
16
32
38
SA
S2
501
C
SA
V2
VA
A
B
X
S2
X
C
SA
V1
VA
S1
B
A
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
21
INSTALLATION AND USE INSTRUCTIONS
Fig.
10
X
Fig.
12
X
SA
VA
VA
Fig.
13
X
S1
V1
Fig.
14
150mm
S1
P1
Stroke 360
24V - 230V
Standard
A1_1
Fig.88Fig.
15
V5
INSTALLATION
1) Open the package and extract the various components;
2)Fig. 10- With a pencil draw the centre line X of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application A1_1. Mark the points for the holes to fasten the brackets S1 and SA;
4) With a suitable drill, create on the window the holes;
5) Fig. 12- Mount the supports SA (RH-LH) on the fix window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6) Fig. 13- Mount the bracket S1 on the movable window frame with the screws V1;
7)Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
8) Fig. 14- Connect the bracket S1 to the chain end using the pin P1;
9) Fig. 15- Place the actuator on the support SA inserting the screw V5 on the support bracket;
VERIFY THAT AFTER T H E T I G H T E N I N G THE BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
10) Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
TOP HUNG Outward opening
SA,S1
Fig.4Fig.
11
X
L1
L2
22
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
SPORGERE
Fig.
10
X
Fig.
13
S2
V2
Fig.
12
SA
VA
Stroke 600
24V - 230V
Standard
A1_1
Fig.
150 mm
Fig.
14
AB AB
Tightening torque
5
2,3 Nm
Fig.88Fig.
15
V5
INSTALLATION
1)Open the package and extract the various components;.
2)Fig. 10- With a pencil draw the centre line “X” of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application A1_1. Mark the points for the holes to fasten the brackets S2 and SA;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SA (RH-LH) on the fix window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 13- Mount the bracket S2 on the movable window frame with the screws V2;
7)Fig. 14- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator; secure the chain terminal to the frame mount; first fit the long side of the shaft and then insert the entire assembly. Move the square plate to the centre of the mount and hand tighten bolt A. Now insert bolt B (included) into the frame mount and tighten both bolts down fully with a 2.5mm hex wrench (torque to 2,3 Nm);
8)Fig. 15- Place the actuator on the support SA inserting the screw V5 on the support bracket;
V E R I F Y T H A T AF T E R T H E T I G H T E N I N G T H E BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
TOP HUNG Outward opening
Fig.4Fig.
11
X
L1
L2
SA,S2
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
23
INSTALLATION AND USE INSTRUCTIONS
A2
A2
Stroke 600- 1000
24V - 230V
Standard - RWA
Stroke 360
24V - 230V
Standard -RWA
BOTTOM HUNG Outward opening
BOTTOM HUNG Outward opening
Casement
Frame
Overlap
C
A
B
Casement
Frame
Overlap
C
A
B
SA ,S1
SA ,S2
24.5
X
L1=183.7
L2=184.3
368
16
SA
S1
392
L1 L2 Stroke 600 283 194 Stroke 1000 24V
423
194
Stroke 1000 230V 424.5 298.5
L3 L4
477 501 617 641 723 747
X
L2
L1
L3
16
32
38
SA
S2
L4
C
SA
X
S1
V1
VA
A
B
C
X
S2
SA
V2
VA
A
B
24
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
X
Fig.
10
Fig.
14
150mm
S1
P1
Fig.
12
X
SA
VA
X
Fig.
13
S1
V1
A2
Stroke 360
24V - 230V
Standard - RWA
Fig.88Fig.
15
V5
INSTALLATION
1) Open the package and extract the various components;
2) Fig. 10- With a pencil draw the centre line X of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application A2. Mark the points for the holes to fasten the brackets S1 and SA;
4) With a suitable drill, create on the window the holes;
5) Fig. 12- Mount the supports SA(RH-LH) on the fix window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6) Fig. 13- Mount the bracket S1 on the movable window frame with the screws V1;
7) )Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
8) Fig. 14-Connect the bracket S1 to the chain end using the pin
P1;
9) Fig. 15- Place the actuator on the support SA inserting the screw V5 on the support bracket;
VE R I F Y T H AT AF T E R T H E T I G H T E N I N G T H E BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
10) Perform a test of complete window frame opening and closing.
Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
BOTTOM HUNG Outward opening
SA ,S1
Fig.4Fig.
11
XX
L1
L2
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
25
INSTALLATION AND USE INSTRUCTIONS
Fig.
10
X
Fig.
13
S2
V2
Fig.
12
SA
VA
A2
150 mm
Fig.Fig.
14
AB AB
5
Stroke 600- 1000
24V - 230V
Standard - RWA
V5
Fig.88Fig.
15
INSTALLATION
1)Open the package and extract the various components;
2)Fig. 10- With a pencil draw the centre line X of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application A2. Mark the points for the holes to fasten the brackets S2 and SA;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SA(RH-LH) on the fix window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 13- Mount the bracket S2 on the movable window frame with the screws V2;
7)Fig. 14- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator; secure the chain terminal to the frame mount; first fit the long side of the shaft and then insert the entire assembly. Move the square plate to the centre of the mount and hand tighten bolt A. Now insert bolt B (included) into the frame mount and tighten both bolts down fully with a 2.5mm hex wrench (torque to 2,3 Nm);
8)Fig. 15- Place the actuator on the support SA inserting the
screw V5 on the support bracket;
VE R I F Y T H AT AF T E R T H E T I G H T E N I N G T H E BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing.
Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
BOTTOM HUNG Outward opening
Tightening torque 2,3 Nm
SA ,S2
Fig.4Fig.
11
X
L1
L2
26
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
A3
Stroke 360 - 600 - 1000
24V - 230V
Standard - RWA
BOTTOM HUNG Inward opening
Casement
Frame
Overlap
C
A
B
SB,S3
S3
Y
15
L1
L2
L3
7.5
23
23
SB
L4
L1 L2 L3 Stroke 360 186.9 187.6 374.5 Stroke 600 286 197 483 Stroke 1000 24V 426 197 623 Stroke 1000 230V 427.75 301.75 729.5
L4
392
500.5
640.5 747
S3
V3
SB
VB
C
A
B
Stroke 360
S3
V3
SB
VB
C
B
A
Stroke 600-1000
1
For narrow window frames, the installation of the indicated screw can be omitted
1
1
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
27
INSTALLATION AND USE INSTRUCTIONS
Fig.
10
Y
Fig.
14
V5
A3
Stroke 360 - 600 - 1000
24V - 230V
Standard - RWA
Fig.
13
150mm
INSTALLATION
1)Open the package and extract the various components;
2)Fig. 10- With a pencil draw the centre line Y of the window frame;
3) Fig. 11- Taking as reference the Y-axis previously traced and the hole layout for the application A3. Mark the points for the holes to fasten the brackets S3 and SB;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SB (RH-LH) on the fix window frame with the screws VB; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 12- Mount the bracket S3 on the movable window frame with the screws V3;
7) Fig. 13- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
8)Fig. 14- Attach the chain end to the bottom hung bracket S3 with the screw and nut supplied;
9)Fig. 14- Place the actuator on the support SB inserting the screw V5 on the support bracket;
VE R I F Y T H AT AF T E R T H E T I G H T E N I N G T H E BRACKETS “SB” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing.
Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
BOTTOM HUNG Inward opening
Fig.
11
Y
L1
L2
Fig.
12
Y
S3
V3
SB
VB
Y
SB,S3
28
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
Opening
LH
Opening
RH
A4_1
A4_2
Stroke 360 - 600 - 1000
24V - 230V
Standard - RWA
SIDE HUNG Outward opening
SIDE HUNG
Outward opening
Casement
Frame
Overlap
C
A
B
SA,S2
SA,S4
L1 L2
183.7 184.3
Stroke 600 283 194
Stroke 360
L3
368 477
Stroke 1000 24V 423 194 617 Stroke 1000 230V 424.5 298.5 723
L4
392 501 641 747
F
10,6 11,1 11,1 11,1
G
12,4 11,9 11,9 11,9
X
L2
L1
L3
16
16
32
38
SA
S2
L4
X
L2
L1
L3
16
16
32
38
SA
S4
L4
S2
X
SA
VA
V2
C
B
A
F
X
SA
V4
VA
C
B
A
G
S4
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
29
INSTALLATION AND USE INSTRUCTIONS
Fig.
10
X
Fig.4Fig.
11
X
L1
L2
Fig.
12
SA
VA
Fig.
13
S2
V2
Fig.4Fig.
14
S4
V4
Fig.
17
Fig.4Fig.
15
Fig.
16
150 mm
AB AB
5
Opening
LH
Opening
RH
A4_1
A4_2
Stroke 360 - 600 - 1000
24V - 230V
Standard - RWA
V5
SA
SIDE HUNG Outward opening
SIDE HUNG
Outward opening
Tightening torque 2,3 Nm
SA,S2
SA,S4
30
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
INSTALLATION
1)Open the package and extract the various components;
2)Fig. 10- With a pencil draw the centre line X of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application A4_1 (A4_2). Mark the points for the holes to fasten the brackets S2(S4) and SA;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SA(Up-Dwn) on the fix window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 13- Mount the bracket S2 on the movable window frame with the screws V2(A4_1); 6a)Fig. 14- Mount the bracket S4 on the movable window frame with the screws V4(A4_2);
7)Fig. 16- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator; secure the chain terminal to the brackets S2(S4) ; first fit the long side of the shaft and then insert the entire assembly. Move the square plate to the centre of the mount and hand tighten bolt A. Now insert bolt B (included) into the frame mount and tighten both bolts down
fully with a 2.5mm hex wrench (torque to 2,3 Nm);
8)Fig. 17- Place the actuator on the support SA inserting the screw “V5” on the support bracket;
VERI F Y T H AT A F T E R T H E TIGHTENING THE BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing.
Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
Opening
LH
Opening
RH
A5_1
A5_2
Stroke 360-600-1000
24V - 230V
Standard - RWA
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS /INSTALLATION INSTRUCTIONS-10
31
INSTALLATION AND USE INSTRUCTIONS
SIDE HUNG Inward opening
SIDE HUNG
Inward opening
SB,S3
SB,S3
Stroke 600
Stroke 360
Stroke 1000 24V
426
Stroke 1000 230V
427.75
L1 L2
186.9
187.6 286
197
L3
374.5 483
197
623
301.75
729.5
L4
392
500.5
640.5 747
Stroke 600 - 1000
Stroke 360
B
A
S3
VB
SB
V3
Stroke 360
A
VB
SB
S3
V3
B
SB
C
B
A
S3
VB
V3
Stroke 600 - 1000
A
B
C
SB
S3
VB
V3
15
23
23
L2
L1
L3
7.5
15
7.5
L4
Y
Casement
Frame
Overlap
C
A
B
1
1
1
1
For narrow window frames, the installation of the indicated screw can be omitted
1
Fig.4Fig.
11
Fig.4Fig.
15
Opening
LH
Opening
RH
A5_1
A5_2
24V - 230V
Standard - RWA
Fig.
10
Y
Y
L1
L2
Fig.
12
Fig.
13 Fig.4Fig.
14
150mm
SB
VB
S3
V3
32
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
SIDE HUNG Inward opening
SIDE HUNG
Inward opening
Fig.
16
V5
SB
Cable outlet side
SB,S3
SB,S3
Stroke 360-600-1000
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
33
INSTALLATION AND USE INSTRUCTIONS
INSTALLATION
1)Open the package and extract the various components;
2)Fig. 10- With a pencil draw the centre line Y of the window frame;
3) Fig. 11- Taking as reference the Y-axis previously traced and the hole layout for the application A5_1 (A5_2). Mark the points for the holes to fasten the brackets S3 and SB;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SB on the fix window frame with the screws VB; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 13- Mount the bracket S3 on the movable window frame with the screws V3;
7) Fig. 15- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
8)Fig. 16- Attach the chain end to the bracket S3 with the screw and nut supplied;
9)Fig. 16- Place the actuator on the support SB inserting the screw V5 on the support bracket;
VER I F Y T HAT A F T E R T H E TI G H T ENI N G T H E BRACKETS “SB” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing.
Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
Stroke 360
24V
Standard
A1_2 A1_3
A1_4
34
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
TOP HUNG Double Push point Outward opening
SC, SD, SE, S1, M1
95.5 81
48
62.4
17.3
31
18
M1
SD
S1
A1_3
V1
VD
A1_4
M1
VE
S1
V1
SE
61.4
48
81
100.5100.5
26
23.5
2.3
2.3
10.3
11.2
95.5
48
81
62.4
17.3
31
18
M1
SC
S1
A1_2
V1
VC
A
B
B
A
B
A
C
C
C
80
80
S1
M1
X1
X2
X1’
X2’
X
SC
30
18
26.5
44.5
SD
26,5 44,5
18
S1
24.5
5
6
46
SE
46
25
26
57
Casement
Frame
Overlap
C
A
B
Fig.
16
SC
M1
SC
Fig.
12
S1
V1
VC
Fig.15Fig.
14
M1
20202020
A1_2
Stroke 360
24V
Standard
Fig.
15
P1
150 mm
Fig.
13
S1
SC
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
35
INSTALLATION AND USE INSTRUCTIONS
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line X of the window frame. Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Fig.11 - Trace axis X1' and X2'; Taking as reference the axis X1,X1’ and X2,X2’ previously traced and the hole layout for the application A1_2, mark the points for the holes to fasten the brackets S1 and SC;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S1 with V1 and the two frame brackets SC with VC;
6)Fig. 14 - Insert the two pairs of clamps “M1“ for the tophinged applications, fitting them in the actuator slider adjacent to the chain terminal, then close them partially with the screw and nut in the package;
7) Fig.14 - Position the clamps 80mm on either side of the chain terminal midline and tighten the screw all the way;
8) Fig.15 - Perform the electric connections according to the provisions of par. 5.3, as
well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
9)Fig.15- 16 - First fasten the chain terminal to the S1 with P1 , then fasten the clamps
M1 to the brackets for connection to the window SC . Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10) Connect the power actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
TOP HUNG Double Push point Outward opening
SC, S1,M1
Fig.
10
X
L/2
L/2
X2
X1
X2
X1
X1’
X2’
80
80
Fig.
11
X2
X2’
Fig.
12
SD
S1
VD
V1
Fig.
13
S1
SD
Fig.15Fig.
14
M1
Fig.
16
M1
SD
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line X of the window frame. Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Trace axis X1' and X2'; Taking as reference the axis X1, X1’ and X2,X2’ previously traced and the hole layout for the application A1_3, mark the points for the holes to fasten the brackets S1 and SD;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S1 with “V1” and the two frame brackets SD with VD;
6)Fig. 14 - Insert the two pairs of clamps “M1“ for the tophinged applications, fitting them in the actuator slider adjacent to the chain terminal, then close them partially with the screw and nut in the package;
7) Fig.14 - Position the clamps 80mm on either side of the chain terminal midline and tighten the screw all the way;
8) Fig.15 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
9)Fig.15- 16 - First fasten the chain terminal to the S1 with P1 , then fasten the clamps
M1 to the brackets for connection to the window SD . Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10)Connect the power actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
A1_3
Stroke 360
24V
Standard
Fig.
15
P1
150 mm
36
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
TOP HUNG Double Push point Outward opening
Fig.
10
X
L/2
L/2
X2
X1
SD, S1, M1
X2
X1
X1’
X2’
80
80
X2
X2’
Fig.
11
A1_4
Stroke 360
24V
Standard
M1
Fig.15Fig.
14
Fig.
12
SE
VE
S1
V1
Fig.
16
M1
SE
Fig.
13
S1
SE
Fig.
15
P1
S1
150 mm
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line X of the window frame.
Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Fig.11 - Trace axisX1' and B'; Taking as reference the axis X1,X1’ and X2,X2’ previously traced and the hole layout for the application A1_4, mark the points for the holes to fasten the brackets S1 and SE;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S1 with V1 and the two frame brackets SE with VE;
C160
USO E FUNZIONAMENTO -6DRAWINGS / INSTALLATION INSTRUCTIONS -10
37
INSTALLATION AND USE INSTRUCTIONS
6)Fig. 14 - Insert the two pairs of clamps “M1“ for the tophinged applications, fitting them in the actuator slider adjacent to the chain terminal, then close them partially with the screw and nut in the package;
7) Fig.14 - Position the clamps 80mm on either side of the chain terminal midline and tighten the screw all the way;
8) Fig.15 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
9)Fig.15- 16 - First fasten the chain terminal to the S1 with P1 , then fasten the clamps
M1 to the brackets for connection to the window SE . Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10) Connect the power actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
TOP HUNG Double Push point Outward opening
SE, S1, M1
Fig.
10
X
L/2
L/2
X2
X1
X1’
X2’
X2
X1
80
80
Fig.
11
80
X2’
X2
C160
Stroke 360
24V
Standard - RWA
A2
38
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
BOTTOM HUNG Double Push point Outward opening
SF, S1, M1
95.5
68.5
16.5
32
18
M1
SF
S1
48
62.4
VF
V1
A
B
C
80
80
S1
M1
X1
X2
X1’
X2’
X
3
S1
24.5
5
6
18
26.5
44.5
59.5
SF
18
26.5
44.5
59.5
Casement
Frame
Overlap
C
A
B
Fig.
13
Fig.15Fig.
14
M1
Stroke 360
24V
Standard - RWA
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line X of the window frame.
Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Fig.11 - Trace axis X1 ' and X2'; Taking as reference the axis X1,X1 ’ and X2,X2’ previously traced and the hole layout for the application A2, mark the points for the holes to fasten the brackets S1 and SF;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S1 with V1 and the two frame brackets SF with VF;
6)Fig. 14 - Insert the two pairs of clamps
“M1“ for the tophinged applications, fitting
them in the actuator slider adjacent to the
chain terminal, then close them partially with
the screw and nut in the package;
7) Fig.14 - Position the clamps 80mm on either side of the chain terminal midline and tighten the screw all the way;
8) Fig.15 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
9)Fig.15- 16 - First fasten the chain terminal to the S1 with P1 , then fasten the clamps M1 to the brackets for connection to
the window SF . Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10) Connect the power actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
M1
SF
Fig.
16
Fig.
12
SF
S1
V1
VF
Fig.
15
P1
S1
150 mm
A2
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
39
INSTALLATION AND USE INSTRUCTIONS
BOTTOM HUNG Double Push point Outward opening
Fig.
10
X
L/2
L/2
X1
X2
SF, S1, M1
X1’
X2’
80
80
X2
X1
Fig.
11
X2’
X2
Stroke 360
24V
Standard - RWA
A3
40
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
BOTTOM HUNG Double Push point Inward opening
SG, S3, M2
48
>60
96.2
10.9
119
108.5
79.5
102
18
11.6
9.6
25
34.4
S3
SG
M2
V3
VG
AA
B
Y
Y1
Y2
S3
19
12
13
13
23
23
24
34.1
2.5
9.6
11.6
5.6
118.97
108.5
23
23
SG
Casement
Frame
Overlap
C
A
B
Fig.
13
Fig.
15
1
2
S3
SG
M2
Fig.15Fig.
14
M2
Stroke 360
24V
Standard - RWA
A3
Fig.
12
S3
SG
V3
VG
27
Fig.15Fig.
17
150mm
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
41
INSTALLATION AND USE INSTRUCTIONS
BOTTOM HUNG Double Push point Inward opening
SG, S3, M2
Fig.
10
Y
L/2
L/2
Y1
Y2
Y1
Y2
Fig.
11
Fig.
16
M2
S3
SG
Fig.
18
S3
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line Y of the window frame. Measure he distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline Y marked previously, trace axis Y1 and Y2;
3)Fig.11 - Taking as reference the axis Y1 and Y2 previously traced and the hole layout for the application A3, mark the points for the holes to fasten the brackets S3 and SG;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S3 with
V3 and the two frame brackets SG with VG;
Before using the screws in the hardware package, make sure they are suitable for the type of window.
6) Fig.14 - Close the two pairs of clamps M2 for bottomhinged application partially with the screws and nut provided in the package;
7) Fig.15 - Fit the two pairs of clamps previously Assembled M2 with the brackets for bottom-hinged application SG (window frame);
WARNING: do not damage the swivel bracket when fitting the clamps;
make sure that the window brackets are correctly fastened to
their clamps.
8) Fig.16 - Fit the actuator into the clamps M2 through the tracks on the actuator. Centre the chain-end on the bottom-hinged bracket, then firmly close the clamps;
9) Fig.17 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
10) Fig.18 - Fasten the chain terminal to the bottomhinged Bracket
S3 (wing) with the screw and nut provided in the package. WARNING: tighten the nut up to the stop with the bracket, not over as this may compromise the correct functioning of the actuator.
The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
11) Power the actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
42
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
Opening
LH
Stroke 360
24V
Standard - RWA
A4_1
A4_2
Opening
RH
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
43
INSTALLATION AND USE INSTRUCTIONS
SIDE HUNG Double Push point Outward opening
SIDE HUNG Double Push point Outward opening
S1
31
17.5 18
95.5 81
62.4
48
SF
M1
V1
VF
AA
B
C
80
80
S1
M1
X1
X2
X1’
X2’
X
SF, S1, M1
SF, S1, M1
S1
31
17.5
18
62.4
48
95.5
81
SF
M1
V1
VF
AA
B
C
3
18
26.5
44.5
59.5
SF
18
26.5
44.5
59.5
S1
24.5
5
6
Casement
Frame
Overlap
C
A
B
Fig.
13
Fig.
15
M1
P1
Fig.
14
SF
S1
150mm
Fig.
12
S1
SF
SF
S1
VF
V1
V1
VF
44
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
Opening
LH
Stroke 360
24V
Standard - RWA
A4_1
A4_2
Opening
RH
SIDE HUNG Double Push point Outward opening
SIDE HUNG Double Push point Outward opening
X
X
X1
X2
L/2
L/2
Fig.
10
X
X1
X2
Fig.
11
X1’
X2’
80
80
SF, S1, M1
SF, S1, M1
Fig.
16
M1
SF
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 -With a pencil draw the centre line X of the window frame. Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Fig.11 - Trace axis X1' and X2'; Taking as reference the axis X1,X1’ and X2,X2’ previously traced and the hole layout for the application A4_1 (A4_2), mark the points for the holes to fasten the brackets S1 and SF;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S1 with V1 and the two frame brackets SF with VF;
7) Fig. 14 - Insert the two pairs of clamps “M1“ , fitting them in the
actuator slider adjacent to the chain terminal, then close them partially with the screw and nut in the package;
8) Fig.14 - Position the clamps 80mm on either side of the chain
terminal midline and tighten the screw all the way;
9) Fig.15- Perform the electric connections according to the
provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
10) Fig.16 - First fasten the chain terminal to the S1 with P1 , then
fasten the clamps M1 to the brackets for connection to the window SF; Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10) Connect the power actuator.
Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
45
INSTALLATION AND USE INSTRUCTIONS
Opening
LH
Stroke 360
24V
Standard - RWA
A5_1
A5_2
Opening
RH
46
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
SIDE HUNG Double Push point Inward opening
SIDE HUNG Double Push point Inward opening
Y
Y1
Y2
SG
S3
19
12
13
13
23
23
24
34.1
2.5
9.6
11.6
5.6
118.97
108.5
23
23
48
>60
96.2
10.9
119
108.5
79.5
102
18
11.6
9.6
25
34.4
S3
SG
M2
V3
VG
A A
B
48
>60
96.2
10.9
119
108.5
79.5
102
18
11.6
9.6
25
34.4
S3
SG
M2
V3
VG
A
A
B
SG, S3, M2
SG, S3, M2
C
C
Casement
Frame
Overlap
C
A
B
Fig.
15
Fig.
14
Y
Y
Fig.
12
Fig.
13
1
2
S3
SG
M2
M2
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
47
INSTALLATION AND USE INSTRUCTIONS
Opening
LH
Stroke 360
24V
Standard - RWA
A5_1
A5_2
Opening
RH
SIDE HUNG Double Push point Inward opening
SIDE HUNG Double Push point Inward opening
Fig.
10
SG, S3, M2
SG, S3, M2
Fig.
11
Y1
Y2
Y1
Fig.
19
Fig.
17
150mm
Fig.
18
S3
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line Y of the window frame. Measure he distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline Y marked previously, trace axis Y1 and Y2;
3)Fig.11 -Taking as reference the axis Y1 and Y2 previously traced and the hole layout for the application A5_1(A5_2), mark the points for the holes to fasten the brackets S3 and SG;
4)Fig. 11 -With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two movable window brackets S3 with V3 and the two frame brackets SG with VG; Before using the screws in the hardware package, make sure they are suitable for the type of window;
6) Fig.14 - Close the two pairs of clamps M2 partially with the screws and nut provided in the package;
7) Fig.15 - Fit the two pairs of clamps previously Assembled M2 with the brackets SG (window frame);
WARNING: do not damage the swivel bracket when fitting the clamps;
Make sure that the window brackets are correctly fastened to their clamps.
8) Fig.16 - Fit the actuator into the clamps M2 through the tracks on the actuator. Centre the chain-end on the bracket, then firmly close the clamps;
9) Fig.17 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
10) Fig.18 - Fasten the chain terminal to the Bracket S3 (wing)
with the screw and nut provided in the package.
WARNING: tighten the nut up to the stop with the bracket, not over as this may compromise the correct functioning of the actuator.
The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
11) Power the actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
48
10- DRAWINGS / INSTALLATION INSTRUCTIONS
INSTALLATION AND USE INSTRUCTIONS
C160
Fig.
16
M2
S3
SG
Stroke 360
24V - 230V
Standard - RWA
Stroke 600 - 1000
24V - 230V
B1
B1
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS -10
49
INSTALLATION AND USE INSTRUCTIONS
Standard - RWA
B
A
C
66.8
90.8
19.6
1421
54.6
SA
S1
V1
VA
X
10.2- Actuator mounting on movable windows.
C
B
AA
11.1
1421
46.1
66.8
90.8
SA
S4
V4
VA
X
On the window BOTTOM HUNG Inward opening
Casement
Frame
Overlap
C
A
B
Casement
Frame
Overlap
C
A
B
On the window BOTTOM HUNG Inward opening
24.5
X
L1= 184.3
L2= 183.7
368
16
16
SA
S1
392
SA, S1
SA, S4
Stroke 600 194 283 Stroke 1000 24V 194 423
L1 L2
Stroke 1000 230V 298.5 424.5
477 617
L3
723
501 641
L4
X
32
38
SA
16
S4
16
L1
L3
L2
L4
747
Fig.
10
Fig.
14
INSTALLATION
1) Open the package and extract the various components;.
2)Fig. 10- With a pencil draw the centre line X of the window frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application B1. Mark the points for the holes to fasten the brackets S1 and SA;
4) With a suitable drill, create on the window the holes;
5) Fig. 12- Mount the supports SA (RH-LH) on movable window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6) Fig. 13- Mount the bracket S1 on the fix window frame with the screws V1;
7)Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
8) Fig. 14- Connect the bracket S1 to the chain end using the pin
P1;
9) Fig. 15- Place the actuator on the support SA inserting the screw V5 on the support bracket;;
VERIFY THAT AFTER THE TIGHTENING THE BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
10) Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
Stroke 360
24V - 230V
B1
X
Fig.
13
X
S1
V1
150mm
S1
P1
Standard - RWA
50
INSTALLATION AND USE INSTRUCTIONS
10- DRAWINGS / INSTALLATION INSTRUCTIONS
C160
Fig.
15
V5
SA, S1
Fig.4Fig.
11
X
X
SA
VA
Fig.
12
L1
L2
On window BOTTOM HUNG Inward opening
Fig.
10
Fig.
13
Fig.
14
Fig.
15
10
X
S4
V4
150 mm
AB AB
5
INSTALLATION
1) Open the package and extract the various components;.
2)Fig. 10- With a pencil draw the centre line X of the window
frame;
3) Fig. 11- Taking as reference the X-axis previously traced and the hole layout for the application B1. Mark the points for the holes to fasten the brackets S4 and SA;
4) With a suitable drill, create on the window the holes;
5)Fig. 12- Mount the supports SA (RH-LH) on the movable window frame with the screws VA; check the perfect horizontal and vertical alignment with the window frame;
6)Fig. 13- Mount the bracket S4 on the fix window frame with the screws V4;
7)Fig. 14- Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator; secure the chain terminal to the frame mount; first fit the long side of the shaft and then insert the entire assembly. Move the square plate to the centre of the mount and hand tighten bolt A. Now insert bolt B (included) into the frame mount and tighten both bolts down fully with a 2.5mm hex wrench (torque to 2,3 Nm);
8) Fig. 15- Place the actuator on the support SA inserting the screw V5 on the support bracket;
VE R I F Y T H AT A F T E R T H E T I G H T E N I N G T H E BRACKETS “SA” ADHERE TO THE ACTUATOR IN ORDER TO ASSURE A CORRECT APPLICATION.
9) Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.i.
Stroke 600 - 1000
24V - 230V
B1
Standard - RWA
51
INSTALLATION AND USE INSTRUCTIONS
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS-10
V5
Tightening torque 2,3 Nm
SA, S4
Fig.
12
SA
VA
Fig.4Fig.
11
L1
L2
On window BOTTOM HUNG Inward opening
Stroke 360
24V
Standard -RWA
B1
Double push point
52
INSTALLATION AND USE INSTRUCTIONS
10- DRAWINGS / INSTALLATION INSTRUCTIONS
C160
B
AA
C
95.5
18
2.3 2.3
28.9 19.6
48
62.4
S1
V1
VC
SC
SC
15
30
14.5
18
26.5
44.5
S1
3
24.5
5
6
Casement
Frame
Overlap
C
A
B
SC, S1, M1
80
80
S1
M1
X1
X2
X1’
X2’
X
On the window BOTTOM HUNG Inward opening
Stroke 360
24V
Standard -RWA
Fig.
15
P1
S1
150 mm
Fig.
16
Fig.
13
Fig.
12
SC
S1
VC
V1
Fig.15Fig.
14
M1
53
INSTALLATION AND USE INSTRUCTIONS
C160
USO E FUNZIONAMENTO -6
C160
DRAWINGS / INSTALLATION INSTRUCTIONS-10
INSTALLATION
1)Open the package and remove the various components;
2)Fig.10 - With a pencil draw the centre line X of the window frame. Measure the distance L between the two chain terminals of the actuator and mark it on the window, symmetrically to the midline X marked previously, trace axis X1 and X2;
3)Fig.11 - Trace axis X1' and X2'; Taking as reference the axis X1,X1’ and X2,X2’ previously traced and the hole layout for the application B1, mark the points for the holes to fasten the brackets S1 and SC;
4)Fig. 11 - With a suitable drill, create on the window the holes;
5)Fig. 12-13 - Mount the two fix window brackets S1 with V1 and the two brackets SC with VC on the movable frame ;
6)Fig. 14 - Insert the two pairs of clamps “M1“, fitting them in the actuator slider adjacent to the chain terminal, then close them partially with the screw and nut in the package;
7) Fig.14 - Position the clamps 80mm on either side of the chain terminal midline and tighten the screw all the way;
8) Fig.15 - Perform the electric connections according to the provisions of par. 5.3, as well as with reference to the wiring diagram. Power the actuator and let the chain come out for at least 150mm of stroke, then disconnect the actuator;
9)Fig.15- 16 - First fasten the chain terminal to the S1 with P1 , then fasten the clamps M1 to the brackets for connection to
the window SC . Make sure the brackets for connection to the window are correctly fastened to their clamps. The number of clamps necessary for assembly will depend on the length of the actuator: up to 3 meters only 2 clamps are needed, over 3 meters add a third at the center of the actuator.
10) Connect the power actuator. Perform a test of complete window frame opening and closing. Verify that with open window frame, the stroke is some centimetres lower than the stroke limited by window frame mechanical limit devices. Once the closing phase is ended, verify that the window frame is completely closed by checking the seal deflection.
SC, S1, M1
Fig.
10
X
L/2
L/2
X1
X2
Fig.
11
X1’
X2’
80
80
X2
X1
B1
Double push point
On the window BOTTOM HUNG Inward opening
Wiring Diagram
230 V24 V
CLOSE
N
L
OPEN
C160/230
BLACK
GREY
(LIGHT BLUE)
BROWN
CLOSE
24V
OPEN
C160/24
C160/24
BLUE
(BLACK)
BROWN
(RED)
230V~50Hz
C160/230
24V CC (min. 21V - max. 28V)
A A
A A
A
THIS SYMBOL IDENTIFIES THE TOPP ELECTRICAL ACTUATOR
IN WIRING DIAGRAMS.
A
C160
USO E FUNZIONAMENTO -6
C160
ELECTRICAL WIRING DIAGRAM -11
54
INSTALLATION AND USE ISTRUCTIONS
THIS SYMBOL IDENTIFIES THE TOPP ELECTRICAL ACTUATOR
IN WIRING DIAGRAMS.
TOPP S.r.l.
Società a Socio Unico soggetta a direzione e coordinamento di 2 Plus 3 Holding S.p.a.
Via Galvani, 59 - 36066 Sandrigo (VI) - Italia
Tel. +39 0444 656700 - Fax +39 0444 656701
Info@topp.it - www.topp.it
Loading...