TopCold GK60, BC145V, GN60, SD1381, SDN1381 Instruction Manual

Refrigerators/Freezers
Instruction manual
BC145V/GK60/GN60
PLEASE READ THE OPERATION MANUAL BEFORE USING.
SAVE THIS MANUAL FOR LATER USE.
Safety Tips
• Position on a flat, stable surface.
• A service agent/qualified technician should carry out installation and any repairs if required. Do not
remove any components or service panels on this product.
• Consult Local and National Standards to comply with the following:
• Health and Safety at Work Legislation
• BS EN Codes of Practice
• Fire Precautions
• IEE Wiring Regulations
• Building Regulations
• DO NOT use jet/pressure washers to clean the appliance.
• DO NOT use the appliance outside.
• DO NOT use this appliance to store medical supplies.
• DO NOT use electrical appliances inside the appliance (e.g. heaters, ice-cream makers etc.).
• DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean
immediately if contact occurs.
• DO NOT store products on top of the appliance.
• Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the
refrigerator.
• Always carry, store and handle the appliance in a vertical position and move by holding the base of
the appliance.
• Always switch off and disconnect the power supply to the unit before cleaning.
• Keep all packaging away from children. Dispose of the packaging in accordance with the regulations
of local authorities.
• If the power cord is damaged, it must be replaced by a agent or a recommended qualified technician
in order to avoid a hazard.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety
• Children should be supervised to ensure that they do not play with the appliance
Introduction
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your product.
Pack Contents
The following is included:
• Refrigerator / Freezer • Keys x2
• Shelves – 2 big+1 small(200) • Spacers x 2
Shelves – 3 big+1 small(400/600) • Instruction manual Prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage. Should you find any damage as a result of transit, please contact your dealer immediately.
Installation
1. Remove the appliance from the packaging. Make sure that all protective plastic film and coatings are
thoroughly removed from all surfaces.
2. Maintain a distance of 2cm (0.7 inches) between the unit and walls or other objects for ventilation.
Increase this distance if the obstacle is a heat source.
Operation
1. General
ECS-10HT1 could be specially used in kitchen cabinet and air curtain cabinet, unit Celsius and Fahrenheit could be switched by menu, Max. two channel of sensors separately used for cabinet temperature adjustment and defrost control; Compressor and defroster relay could select the specification 30A-10A, or 17A-10A; The display of the controller could be selected as cabinet temperature or evaporator temperature; split design between control board and display panel, very convenient for repairing and replacement.
2. Technical parameters
2.1 Measuring range-50+90 or -58194(only when sensor calibration is 0)
2.2 Resolution1or 1℉;
2.3 Accuracy-4050,±1 5170 ,±2others,±3
or -40122,±2123~158℉,±4℉,others,±6
2.4 Cabinet temperature control range-5090 or -58194
2.5 Power supply220VAC50/60Hz
2.6 Power consumption<3W
2.7 Output capacity
Refrigeration30A/240VACnormal open directly drive a single phase 1.5HP220VAC)load; (or optional) 17A/240VACnormal open directly drive a single phase 1.0HP220VACload Defrost or lighting relay10A/240VACnormal open directly drive heater strip Max.1200W
(220VAC); (or optional) 05A/240VACnormal open directly drive heater strip Max.500W (220VAC). Note: Defrost or lighting relay could be used as lighting relay or defrost relay. When parameter U3=0, defrost/lighting relay is used as defrost output, and it has no function of lighting
control at this time; When parameter U3=1, defrost/lighting relay is used as lighting output, and it has no defrost function,
defrost is proceeded as off-cycle defrost.
2.8 Input terminal: cabinet sensor, evaporator sensor (optional)
2.9 Work ambient temperature0℃~55
2.10 Storage temperature:-25℃~75
2.11 Relative humidity20%85%non condensing
2.12 Front panel protection level: IP65
3. Operation and display panel