Toner Cable T10 User Manual

Telephone: Nationwide: Fax: E-mail: Internet:
07/09
Times Fiber T10 6 Series Drop Cable
215-675-2053 800-523-5947 215-675-7543 info@tonercable.com http://www.tonercable.com
T10 Drop Cable
PART NUMBERS
BRAID COVERAGE
Construction STANDARD PREMIUM TRISHIELD QUADSHIELD Nominal Braid Coverage % 60 90 60 77 60-40 PVC Jacket (Regular)
Single 2360 2560 2622 2627 2260 Single (Colors) 2391 2591 2620 2625 2291 Single Messengered 2364 2564 2623 2628 2264 Siamese 2396 -- -- -- 2296 Siamese (Colors) 2356 -- -- -- 2256 Siamese Messengered 2384 -- -- -- 2284
PVC Jacket (Underground Floodant)
Single Flooded 2386 2586 2624 2629 2260 Siamese Flooded 2353 2553 -- -- 2296
PVC Jacket (lifeTime
TM
Floodant)
Single Flooded 32360 32560 32622 32627 32260 Single Flooded Messengered 32364 32564 32623 32628 32264 Siamese Flooded 32396 -- -- -- 32296 Siamese Flooded Messengered 32384 -- -- -- 32284
PVC Jacket, Flame Retardant - CATV Listed
Single 2360V 2560V 2622V 2627V 2260V Single (Colors) 2391V 2591V 2620V 2625V 2291V Siamese 2396V 2596V -- -- 2296V Siamese (Colors) 2356V -- -- -- 2256V
PVC Jacket, Flame Retardant with lifeTime
TM
- CATV Listed
Single Flooded 32360V 32560V 32622V 32627V 32260V Single Flooded(Colors) 32391V 32591V -- 32625V 32291V Siamese Flooded 32396V 32596V -- -- 32296V
U
L
U
L
6 Series Drop Cable
TIMES FIBER COMMUNICATIONS, INC.
969 Horsham Road
Horsham, Pennsylvania 19044 USA
©Toner Cable Equipment, Inc. Specifications Subject To Change Without Notice.
Telephone: Nationwide: Fax: E-mail: Internet:
Times Fiber T10 6 Series Drop Cable
215-675-2053 800-523-5947 215-675-7543 info@tonercable.com http://www.tonercable.com
PHYSICAL SPECIFICATIONS
NOMINAL DIMENSIONS STANDARD PREMIUM TRISHIELD QUADSHIELD Braid Coverage % 60 90 60 and 77 60-40
inches (mm) inches (mm) inches (mm) inches (mm)
Conductor 0.0403 (1.02) 0.0403 (1.02) 0.0403 (1.02) 0.0403 (1.02) Dielectric 0.180 (4.57) 0.180 (4.57) 0.180 (4.57) 0.180 (4.57) Sealed AP A T ape
(1st Outer Conductor) 0.188 (4.78) 0.188 (4.78) 0.188 (4.78) 0.188 (4.78)
Aluminum Braid
(2nd Outer Conductor) 0.212 (5.38) 0.212 (5.38) 0.212 (5.38) 0.212 (5.38)
Unsealed AP A T ape
(3rd Outer Conductor) -- -- -- -- 0.216 (5.49) 0.216 (5.49)
Aluminum Braid
(4th Outer Conductor) -- -- -- -- -- -- 0.241 (6.12)
Jacket 0.273 (6.93) 0.273 (6.93) 0.278 (7.06) 0.297 (7.54)
Cable Width (Single)
Messenger Diameter (Single) 0.051 (1.30) 0.051 (1.30) 0.051 (1.30) 0.051 (1.30) Single Messenger Width 0.428 (10.9) 0.428 (10.9) 0.433 (11.0) 0.452 (11.5) Siamese Width 0.591 (15.0) 0.591 (15.0) -- -- 0.639 (16.2) Messenger Diameter (Siamese) 0.072 (1.83) -- -- -- -- 0.072 (1.83) Siamese Messengered Width 0.768 (19.5) -- -- -- -- 0.816 (20.7)
Messenger Break Strength Size Minimum Maximum
0.051 in (1.30 mm) 185 lb (823 N) 245 lb (1090 N)
0.072 in (1.83 mm) 365 lb (1624 N) 490 lb (2180 N)
Cable Weight [pounds per 1000 feet (kg/km)]
Regular 60 90 60 77 60-44
Single 28 (42) 29 (43) 28 (42) 29 (43) 33 (49) Single Messengered 40 (60) 41 (61) 40 (60) 41 (61) 45 (67) Siamese 57 (85) -- -- -- -- -- -- 66 (98) Siamese Messengered 77 (115) -- -- -- -- -- -- 86 (128)
Underground
Single Flooded 27 (40) 29 (43) 29 (43) 30 (45) 31 (46) Siamese Flooded 55 (82) 58 (86) -- -- -- -- 63 (94)
lifeTime
TM
Single Flooded 27 (40) 29 (43) 29 (43) 30 (45) 31 (46) Single Flooded Messengered 39 (58) 40 (60) 41 (61) 42 (63) 43 (64) Siamese Flooded 55 (82) -- -- -- -- -- -- 63 (94) Siamese Flooded Messengered 75 (112) -- -- -- -- -- -- 81 (121)
ELECTRICAL SPECIFICATIONS
Nominal DC Resistance at 68° F (20° C) Ohms per 1000 feet (ohms/1000 meters) Braid Coverage % Standard Premium Trishield Quadshield
Conductors 60 90 60 77 60-40
Center Conductor 30.4 (100) 30.4 (100) 30.4 (100) 30.4 (100) 30.4 (100) Outer Conductor 9.13 (30) 5.74 (18) 6.57 (21) 5.49 (18) 4.85 (16) Loop 39.6 (130) 36.0 (118) 36.9 (121) 35.9 (118) 35.3 (116)
Nominal Capacitance-All Types 16.2 pF/ft (53.2 pF/m) Impedance 75 ±3 Ohms Velocity of Propagation 85% nominal
Loading...