Automated or Manual Spectrum Analysis
Frequency Range: TV and Radio 4-1000 Mhz Frequency Resolution: 62.5 Khz RF Input Impedance: 75 ohms DOCSIS Input Impedance: 75 ohms Dynamic Range: 15 dBuV to 125 dBuV
or -45 to +65 dBmV
or -98 to +16 dBm Measurement Resolution: 0.1 dB Level Measurement Acc: 1 dB typ. (2 dB max.) A/V Ratio: 1.5 dB typ. (2 dB max.) C/N Ratio: 2 dB typ. (4 dB max.) Measure Filter Bandwidth: 100 Khz @ -3 dB Custom Channel Plans: 25 Digital Measurements- 8-VSB, QAM 16-32-64-256 (Annex A/B) Frequency Band: 4-1000 Mhz Power Measurement
Dynamic Range: -35 to 56 dBmV BER Measurement: bBER up to 1 x 10-8 (after Reed Solomon) aBER up to 2 x 10-9 MER Measurement: 10 dB to 40dB Constellation Display: 64-128-256 (on graphics display)
DOCSIS Measurements
DOCSIS 2.0 Compliant Device Frequency Band: 5-1000 Mhz Input Impedance: 75 ohms Range: -45 to +65 dBmV Measurements Include: Level, MER, Pre/Post BER,
Lost Packet, Transmit Power, Transmitted Packets, Received Packets, PER, Latency Min/Max/Avg Upstream Level and IP Status
MAC Address: Default or User Defined
General Specifications
Power Supply: Built-in NiCd rechargeable battery
External Power Supply 17 VAC or 20 VDC 1A
Battery Duration at 25°C: 4-6 Hours in Analog
3-4 Hours in Digital Size: H 11.8" x W 4.33" x D 2.36" PC Interface: USB Display: 128 x 128 pixels, 2.5" square Front-panel: Numeric Keypad
Telephone: Nationwide: Fax: E-mail: Internet:
06/10
Sencore SLM1476CM Portable Signal Level Meter
215-675-2053 800-523-5947 215-675-7543 info@tonercable.com http://www.tonercable.com
969 Horsham Road
Horsham, Pennsylvania 19044 USA
SLM1476CM Portable Signal Level Meter
SLM 1476CM Portable Signal Level Meter
The SLM 1476CM provides everything installers and operators are looking for in a signal level meter. Capable of analog and digital measurements, including Pre/Post BER, MER, Spectral Display, DOCSIS 2.0 Network Testing, and Leakage and Ingress Testing capabilities - all at an affordable price. Designed to easily test multiple DOCSIS channels. The SLM 1476 provides a pass/fail test which can be sent directly from the meter.
Specifications
Key Features
1-button testing for simple operation
• Alpha/Numeric keypad for direct channel or frequency entry
• Use the SLM 1476CM for complete modem installation. Test both for­ward and return from premise to CMTS
• Digital measurement capabilities including: Average power, Pre/Post BER, MER, and Constellation for QAM, also provides 8-VSB/ATSC testing capabilities.
• All Channel/Frequency Tuning: From 4-1000 MHz (UHF/VHF/CABLE) allowing return path signal testing as well as testing high-frequency channels with ease
• Analog measurement capabilities including Signal Level, A/V ratio, and C/N
• Signal leakage testing capabilities ensures every installation is clean and meets system requirements
• Ingress capabilities allows for both forward and return path testing from the ground block or line extender to ground block for unwanted noise
• Full featured spectral display enables you to view all channels, a single channel, or a bar graph display for a quick visual inspection of all chan­nels.
• Data logging enables the technician to save or print all data for future reference or record of completed installations. Connect to PC via USB cable and download using FREE interface software
• 12-volt AC/DC charging and Auto-off for battery saving operation
• Threshold test-user definable thresholds for pass/fail logging
Applications
CATV installation & troubleshooting
Off-air 8-VSB reception-broadcast footprint quality
Private cable systems in schools, corporate campuses, correctional institutions and medical centers, anywhere RF is used
Custom home theater installation & calibration
©Toner Cable Equipment, Inc. Specifications Subject To Change Without Notice.