Toner Cable DCWRGST User Manual

969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
The DCWRGST series wall taps from Toner feature a revolutionary newly designed self terminating F port.
The self terminating F port on the tap port of the tap provides a self terminating 75Ω load when the mating F connector is removed.
The F port uses a unique (patent pending) F port design that has a sliding dielec­tric, which closes an internal switch connecting a 75Ω load to the tap. This provides termination and maintains proper match to ensure accurate system performance.
The DCWRGST is a standard 90° type wall tap, typically mounted on a wall plate for flush mounting, and has all the same features as our standard DCWRG wall taps.
The DCWRGST is ideally suited to situations where the connection is only used occasionally, or the cable is removed often, such as in schools or businesses, or any time television is shared amongst multiple outlets.
By using the DCWRGST in these applications, it is no longer necessary for anyone to remember to install a terminator when they disconnect the jumper cable from the wall plate.
Port self terminates when connector is removed
DCWRGST
Self Terminating Wall Tap
969 Horsham Road lHorsham, Pennsylvania 19044 USA l Phone: 215-675-2053 Fax: 215-675-7543 linfo@tonercable.com
TAP VALUE 3 6 9 12 16 20 24 27 30
INSERTION 5-15 MHz 3.6 2.5 1.4 0.9 0.8 0.7 0.7 0.7 0.7
LOSS 15-40 MHz 3.6 2.5 1.4 0.8 0.8 0.7 0.7 0.7 0.7
(Maximum) 40-550 MHz 3.6 2.5 1.4 0.8 0.8 0.7 0.7 0.7 0.7
550-1000 MHz 3.9 2.7 2.2 1.5 1.2 1.2 1.2 1.2 1.2
5-15 MHz ±1.0 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8
TAP 15-40 MHz ±1.0 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8
LOSS 40-550 MHz ±1.0 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8
550-1000 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2
5-15 MHz 35 30 30 30 40 42 45 50 50
ISOLATION 15-40 MHz 40 35 35 35 35 37 38 38 38
(Minimum) 40-550 MHz 30 26 28 30 32 33 35 38 38
550-1000 MHz 30 24 27 27 30 32 32 35 35
RETURN LOSS 5-15 MHz 25 25 22 20 25 25 25 25 25
INPUT 15-40 MHz 25 25 22 25 25 25 25 25 25
(Minimum) 40-550 MHz 22 20 20 20 20 20 20 20 20
550-1000 MHz 22 20 20 20 20 20 20 20 20
RETURN LOSS 5-15 MHz 25 22 22 20 25 30 30 30 30
OUT & TAP 15-40 MHz 30 22 22 28 30 30 30 30 30
(Minimum) 40-550 MHz 22 20 20 22 22 22 22 22 22
550-1000 MHz 22 18 20 20 20 20 20 20 20
Specifications
DCWRGST
Self Terminating Wall Tap
Specifications Subject To Change Without Notice Rev 06-13 ©Toner Cable Equipment, Inc.