Replacement Parts & Ordering Information ........................................................... 7.4
Cus t omer Questionnaire ........................................................................................ 7.16
Drawings
v
vi
SECTION
1
INTRODUCTION
1.0
INTRODUCTION
TOMCO2 EQUIPMENT COMPANY CARBON DIOXIDE DRY
ICE PELLETIZERS
Tomco2 has been a CO2 equipment specialist for over thirty years. Tomco2 manufactures Urethane Insulated CO
CO
ISO Containers, CO2 Particle Filters, CO2 Vaporizers, CO2 Pumps, CO2 Clean-
2
ing Systems, and CO
Tomco
offers a 24-hours a day, 365 days a year, Parts and Service Department. The
2
Water Treatment Systems.
2
Storage Units, Vacuum Insulated CO2 Storage Units,
2
telephone number is 800-832-4262 (toll free in the U.S.) or 770-979-8 000.
Our dry ice pelletizers are available in models capable of producing from 100
hour to 3000 lbs/hour of dry ice pellets. These units are made of the highest quality
lbs/
materials and workmanship.
Thank you for purchasing our CO
dry ice pelletizers, and if we can be of service to
2
you, please contact us.
1.1
INTRODUCTION
UNDERSTANDING CARBON DIOXIDE
Carbon dioxide is a chemical compound formed by combining one atom of carbon
with two atoms of oxygen, and is expressed by the molecular formula CO
. Carbon
2
dioxide can exist in any one or all three states of matter: solid, liquid, and/or vapor;
depending on conditions of temperature and pressure.
Under normal atmospheric conditions, carbon dioxide exists as a colorless, odorless
gas which is about 1.5 times heavier than air. Carbon dioxide will not burn or
support combustion and will not sustain life.
When confined within a suitable pressure vessel, carbon dioxide can exist in any of
three states of matter depending on conditions of temperature and pressure. The
point at which all three states may exist in equilibrium is -69.9
o
F (-56.6 oC) and 60.4
psig (4.2 bar). This is called the triple point. At temperatures and pressures
lower than the triple point, carbon dioxide may be either a solid or a vapor, again
depending on conditions. Dry ice (solid carbon dioxide), at a temperature of -109.3
o
F (-78.5 oC) at atmospheric pressure, sublimes (transforms directly from solid into
vapor without the formation of a liquid).
o
The critical point of carbon dioxide is 87.9
At temperatures and pressures greater than 87.9
F (31.1 oC) and 1070.6 psig (73.8 bar).
o
F (31.1 oC) and 1070.6 psig (73.8
bar), carbon dioxide cannot exist as a liquid. At pressures and temperatures greater
than the critical point, carbon dioxide exist s onl y as a supercritical fluid.
At temperatures and pressures above the triple point and below the critical point,
carbon dioxide liquid with overlying vapor may exist in equilibrium within a closed
vessel. Within this range, there is a definite relationship between te mperature,
pressure, and density.
By following the vapor pressure curve in Figure 1.1 on page 1.3, it becomes obvious
o
that if you desire to store liquid carbon dioxide at 70
F (21.1 oC), the pressure vessel
would have to be bui lt to withs t and pressures of around 840 psig (57.9 bar). By
1.2
INTRODUCTION
following the liquid dens ity curve, one finds that the liquid becomes less dense as the
temperature increases and at 70
per cubic foot (754 kg/m
3
).
By comparing the pressure and liquid density at 70
bar) and 47.6 pounds per cubic foot (764 kg/m
o
F (-17.8 oC) [291.1 psig (20.1 bar) and 63.65 pounds per cubic foot (1022 kg/m3)],
0
it is obvious that relatively large quantities of carbon dioxide liquid can be stored in
relatively small, thin walled pressure vessels; hence low-pressure bulk storage of
CO
.
2
The term "low-pressure" is used in the industry to describe the storage of carbon
dioxide at low temperatures below ambient, usually around 0
relative term and should not be taken literally, as the pressures involved range up to
approximately 350 psig (24.1 bar).
o
F (21.1 oC), the liquid density is around 47 pounds
o
F (21.1 oC) [837.8 psig (57.8
3
)] with the pressure and density at
o
F (-17.8 oC). It is a
Fig. 1.1 - Carbon Dioxide Density & Vapor Pressure Curves
at 70 °F (21.1 °C)
at 32 °F (0 °C)
at 2 °F (-16.7 °C)
at -20 °F (-28.9 °C)
at -69.9 °F (-56.6 °C)
at -109.3 °F (-78.5 °C)
Density of the gas
at 70 °F (21.1 °C)
at 32 °F (0 °C)
Specific gravity of the gas
at 70 °F (21.1 °C)
at 32 °F (0 °C)
Specific volume of the gas
at 70 °F (21.1 °C)
at 32 °F (0 °C)
Density of liquid, saturated
at 70 °F (21.1 °C)
at 32 °F (0 °C)
at 2 °F (-16.7 °C)
at -20 °F (-28.9 °C)
at -69.9 °F (-56.6 °C)
838 psig
491 psig
302 psig
200 psig
60.4 psig
0 psig
0.1144 lb/ft
0.1234 lb/ft
1.522
1.524
8.741 ft
8.104 ft
47.6 lb/ft
58.0 lb/ft
63.3 lb/ft
66.8 lb/ft
73.5 lb/ft
3
3
/lb
/lb
3
3
3
3
3
57.79 bar
33.86 bar
20.83 bar
13.79 bar
4.17 bar
0 kPa
3
3
1.833 kg/m
1.977 kg/m
3
3
1.522
1.524
0.5457 m
0.5059 m
764 kg/m
931 kg/m
1016 kg/m
1072 kg/m
1179 kg/m
3
/kg
3
/kg
3
3
3
3
3
Sublimation temperature (1 atm)-109.3 °F-78.5 °C
Critical temperature87.9 °F31.1 °C
Critical pressure1070.6 psig73.81 bar, abs
Critical density29.2 lb/ft
3
468 kg/m3
Triple point-69.9 °F at 60.4 psig-56.6 °C at 4.16 bar
Latent heat of vaporization
at 32 °F (0 °C)
at 2 °F (-16.7 °C)
at -20 °F (-28.9 °C)
100.8 Btu/lb
119.0 Btu/lb
129.6 Btu/lb
234.5 kJ/kg
276.8 kJ/kg
301.4 kJ/kg
Latent heat of fusion at -69.9 °F (-56.6 °C)85.6 Btu/lb199 kJ/kg
Density of liquid at 2 °F (-16.7 °C)63.3 lb/ft
3
1015.9 kg/m3
Latent heat of sublimation at -109.3 °F (-78.5 °C)245.5 Btu/lb571.0 kJ/kg
Table 1.1 - Physical Constants of Carbon Dioxide
1.4
INTRODUCTION
LEARNING MORE ABOUT CARBON DIOXIDE
An important part of maintaining a carbon dioxide dry ice pelletizer is understanding
the properties of CO
. Therefore, maintenance and service of your pelletizer should
2
be performed only by a qualified carbon dioxide equipment technician.
To start or increase your knowledge of carbon dioxide, we recommend that you begin with the pamphlets and literature from the CGA (Compressed Gas Association).
The CGA has a number of pamphlets and videos on CO
and CO2 equipment.
2
We recommend:
G-6 Carbon Dioxide
G-6.1 Standard for Low Pressure Carbon Dioxide Systems at Consumer S ites
G-6.4 Safe Transfer of Low Pressure Liquefied Carbon Dioxide in Cargo Tanks,
Tank Cars and Portable Containers
AV-7 Characteristics and Safe Handling of Carbon Dioxide
The CGA has other publications, vi deos, etc. that pertain to the CO
and CO2 equip-
2
ment. Contact the CGA for a list of available publications at:
Compressed Gas Association
1725 Jefferson Davis Hwy.
Suite 1004
Arlington, VA 22202-4102 USA
Phone: (703) 412-0900
1.5
CARBON DIOXIDE DRY ICE PELLETIZER
INTRODUCTION
SPECIFICATIONS
METHOD OF OPERATION: The dry ice Pelletizer consists of a system for
injecting liquid CO
into a compression cylinder. The process of reducing the
2
pressure on the liquid from approximately 300 psi (20.68 bar), below the Triple
Point, to atmospheric pressure causes about 40% of the carbon dioxide to
change to a solid. The remaining carbon dioxide changes to a vapor and is
vented from the machine. Finally, the solid is hydraulically extruded through
a die to form dry-ice pellets. These pellets can range in size from 0.114” (2.9
mm) to 3/4” (19.05 mm) diameter. The LB-450 disk press has an extra step
that takes the extruded pellets and forms them into a disk 4” (101.6 mm) in
diameter by 1/2” (12.7 m m) thick.
HYDRAULIC SYSTEM:
•High oil temperature automatic shut-off (greater than 150 ºF (65.5 ºC))
•Low oil level automatic shut-off
•High pressure relief valve (see Tabl e 1.2 on page 1.7 for actual setting of
each model
ELECTRICAL: Available to meet electrical requirements worldwide
(Capacities may vary due to frequency variation.)
FEATURES:
•U.S.D.A (United States Department of Agriculture) approved
•Automatic (unattended) operat ion
1.6
INTRODUCTION
High
Capacity
LB-450
1500
HP-1000 DE89RB-
1000
57 3/4”
(146.7cm)
46"
(116.8 cm)
50"
(127.0 cm)
46"
(116.8 cm)
46"
(116.8 cm)
128 7/8”
(327.3cm)
78"
(198.0 cm)
118"
(300 cm)
117"
(297.2 cm)
117"
(297.2 cm)
93”
79"
81"
84"
81"
8000 lbs
(236.2cm)
2500 lbs
(201 cm)
5018 lbs
(206.0 cm)
4000 lbs
(213.4 cm)
3700 lbs
(206.0 cm)
(3636 kg)
40 seconds
per cylinder
(1136 kg)
(2280 kg)
(1818 kg)
(1682 kg)
per disc
8 seconds
per cylin-
40 seconds
55 seconds
per cylinder
55 seconds
per cylinder
2
der
50 hp
(37.3 kW)
15 HP
(11.2 kW)
25 HP
(18.6 Kw)
25 HP
(18.6 kW)
20 HP
(15 kW)
ters)
(832.7 li-
220 gallons
(455 liters)
120 gallons
(455 liters)
120 gallons
(455 liters)
120 gallons
(455 liters)
120 gallons
4000psi
(276 bar)
(152 bar)
2200 psig
3000 psig
(206.8 bar)
3000 psig
(206.8 bar)
3000 psig
(206.8 bar)
HP-500DE89RB-
46"
46"
500
117"
(116.8 cm)
117"
(116.8 cm)
HP-200 DE89RB-
MODEL DE89RB-
40"
40"
100-US
WIDTH
40"
(101.6 cm)
40"
(101.6 cm)
LENGTH
84"
(297.2 cm)
81"
(297.2 cm)
60"
(101.6 cm)
60"
(101.6 cm)
HEIGHT
3200 lbs
(213.4 cm)
2770 lbs
(206.0 cm)
945 lbs
(152.4 cm)
945 lbs
(152.4 cm)
APPROX.
(1455 kg)
55 seconds
(1256 kg)
55 seconds
(429 kg)
43 seconds
(429 kg)
25 seconds
WEIGHT
CYCLE TIME
per cylinder
per cylinder
per cylinder
1 2 1 1 2 2 2 3
per cylinder
CYLINDERS
NUMBER OF
25 HP
(18.6 kW)
15 HP
(11.2 kW)
7.5 HP
(5.6 kW)
7.5 HP
(5.6 kW)
MOTOR
(455 liters)
120 gallons
(455 liters)
120 gallons
35 gallons
(133 liters)
35 gallons
(133 liters)
HYDRAULIC
OIL CAPACITY
3000 psig
(206.8 bar)
3000 psig
(206.8 bar)
Table 1.2 - Dry Ice Pelletizer Dimensional Data
(186 bar)
2700 psig
(186 bar)
2700 psig
RELIEF
PRESSURE
HYDRAULIC
1.7
SECTION
2
CARBON DIOXIDE
SAFETY
2.0
CARBON DIOXIDE SAFETY
The text in this section has been adapted from CGA (Compressed Gas Association)
publication CGA G-6 – 1984: Carbon Dioxide
.
GENERAL SAFETY CONSIDERATIONS
Gaseous carbon dioxide is an asphyxiant. Concentrations of 10% or more ca n produce unconsciousness or death. Lower concentrations may cause headache, sweating, rapid breathing, increased heart rate, shortness of breath, dizziness, mental depression, visual disturbances, and shaking. The seriousness of the latter manifestations is dependent on the concentration of carbon dioxide and the length of time the
individual is exposed.
Carbon dioxide is an odorless gas and should be treated as a material with poor
warning properties. It is denser than air, and high concentrations can persist in open
pits, tanks, or low depressions on the terrain. Before entering such an area, carbon
dioxide monitoring should be carried o ut and the area cleared by forced venti l ati on,
or a self-contained, supplied air respirator should be worn.
Appropriate warning signs shoul d be affixed outside of those areas where high concentrations of carbon dioxide gas can accumulate. An example is shown below:
CAUTION - CARBON DIOXIDE GAS
Ventilate the area before entering.
A high CO
gas concentration
2
may occur in this area
and may cause suffocation.
2.1
CARBON DIOXIDE SAFETY
RESCUE
Do not attempt to remove the individual without utilizing proper rescue equipment or
you may also become a casualty. If the exposed person is unconscious, obtain assistance and put into effect the established emergency procedures.
INHALATION FIRST AID
Inhalation of gaseous carbon dioxide can adversely affect body function. Skin, eye,
or mouth contact with dry ice (solid carbon dioxide) or compressed carbon dioxide
can cause adverse effects.
If a person has inhaled large amounts of carbon dioxide and is exhibiting adverse effects, move the exposed individual to fresh air at once. If breathing has stopped, perform artificial respiration. Keep the affected person warm and at rest. Get professional medical attention immediately.
EXTERNAL EXPOSURE FIRST AID
Skin or mouth contact with dry ice or with vapor or liquid carbon dioxide discharged
from a container may result in frostbite, causing skin lesions or more serious injury
from deep freezing of the tissues.
If dry ice or compre ssed CO
the exposure immediately. If frostbite has occurred, obtain professional medical attention immediately. Do not rub the area. Do not apply heat warmer than 107 °F
(41.7 °C).
Eye contact with dry ice or compressed CO
Frostbite of the eye structure may also occur.
If dry ice or CO
vapor or liquid comes in contact with the eyes, stop the exposure
2
and obtain professional medical attention immediately.
vapor comes in contact with the skin or mouth, stop
2
should be considered as a corneal burn.
2
2.2
SECTION
3
INSTALLATION
3.0
INSTALLATION
INSTALLATION
Following is the standard installation procedure for a Tomco2 Equipment Co. carbon
dioxide dry ice pelletizer. Note: This should be performed by a qualified carbon dioxide equipment technician only. Refer to Figure 3.1 on page 3.3.
Note: A liquid CO
quired for satisfactory performa nce. Contact Tomco
pressure will be lower than 250 psig (17.23 bar). Contact Tomco
liquid CO
Dew point will be above –60°F (-51.1°C).
2
supply pressure of 250 to 300 psig (17.23 to 20.68 bar) is re-
2
Equipment Co. if liquid CO2
2
Equipment Co. if
2
1. Install an insulate d connecting line between the liquid process isolation valve on
the carbon dioxide storage unit and the 1” FNPT (1/2” on 100lb and 200lb machines) (1 1/2” on high capacity machines) connection on the rear of the pelletizer. We recommend that you use pre-insulated (2 1/2” (63.5 mm) urethane) 1
1/8” (1 5/8” on high capacity) Type K copper. However, 1” NPT (1 1/2” on high
capacity) schedule 80 seamless pipe can be substituted. Include in this line a core
type liquid CO
filter. We recommend a Sporlan Valve Co. model C-1449G for
2
1 1/8” copper or a Sporlan Valve Co. model C-1448P for 1” NPT pipe. Each of
these filters uses a single Sporlan Valve Co. core model RC-4864. (Filters are
available from Tomco
25’ (7.62 m). Tomco
Parts and Service.) This line should be no longer tha n
2
recommends the use of an automatic va por purge devic e
2
on any pelletizer that has more than 25’ (7.62m) of liquid supply piping. Contact Tomco
Equipment Co. if the installation will require more than
2
25’ (7.62m) of liquid supply pipi ng. The above is for a single machine opera tion.
If several machines are connected to the same liquid line, consider using sizes
larger than mentioned above.
Using an undersized liquid line will result in decreased production.
2. Install a connecting line between the vapor process isolation valve on the carbon
dioxide storage unit and the 1/4” FNPT connection on the rear of the pelletizer.
The construction material of this line is not critical and is up to the installer’s discretion, but it must be approved for at least 350 psig (24.1 bar).
3.1
INSTALLATION
Note: If isolation valves are included in the connecting lines (steps 1 & 2),
you must install a safety relief valve between the optional isolation valve and
the liquid or vapor process isol ation valves at the storage unit in the event
that carbon dioxide becomes trapped between the two valves.
TRAPPING CARBON DIOXIDE IN A PIPE WITHOUT A SAFETY RELIEF VALVE CAN RESULT IN
A RUPTURE OF THE PIPE CAUSING SERIOUS
INJURY OR DEATH!
DANGER
3. Install a low-pressure check valve (no greater than 5 psi cracking pressure) on the
exhaust port of each heat exchanger and vent to the outdoors using either a flexible hose or suitable piping. Tomco
valves and piping if needed. Slope piping at least 1/4” per foot (20mm per me ter)
away from the pelletizer and include a downturn in the piping to prevent moisture
from entering the pelletizer.
Note: Forced air ventilation is not a sufficient means of removing carbon
dioxide vapor. The exhaust ports must be vented to the outdoors.
Parts and Service can supply the check
2
CARBON DIOXIDE IS AN ASPHYXIANT AND
WHEN RELEASED IN HIGH CONCENTRATIONS
AND IN CONFINED AREAS CAN CAUSE SUFFOCATION AND DEATH! CO2 VAPOR IS HEAVIER
THAN AIR AND WILL ACCUMULATE IN LOW AR-
DANGER
4. Fill the hydraulic fluid reservoir to the top of the sight glass with a good quality
hydraulic fluid (R ando HD68 or equal) with a fluid viscosity of 150-300 SUS
EAS OR DEPRESSIONS.
(ISO 32-68) @ 100 ºF (37.7 ºC).
3.2
INSTALLATION
Note: U.S.D.A. appr oved equipment must use a food grade hydraulic fluid
with similar properties (Citgo Clarion FG ISO 68 or equal).
5. Install conduit s uitable for four wires between the top right side of the control
panel (above the transformer) and the rear outer panel. Use wires that are the
same size or larger than the largest gauge wires in the control panel. Use clamp
type conduit bulkhead fittings with anti-chafe bushings.
6. Install three wires and a protective earth wire (see included electrical drawing for
wire size) from an appropriate power source through the conduit, leaving enough
wire inside the control panel to reach the top of the disconnect switch. Attach
the green protective earth ground wire to the ground terminal. Ground the pelletizer before use because static electricity can build up on the pelletizer under certain conditions.
Be sure that the power source is
WARNING:
turned off.
7. Strip the proper amount (as recommended by the ferrule manufacturer) of insulation from the wires and secure ferrules on the bare ends. Place ends in the terminals at the top of the disconnect switch (DIS-1) and tighten securely. Close the
control panel and be sure the disconnect switch (DIS-1) is off.
8. Turn on the power at the power source. Turn on the disconnect switch (DIS-1) at
the control panel and press the START button. Observe the rotation of the electric motor. If the motor rotates in the same direction as the reference arrow on
the motor, the electrical connections are correct.
9. If the motor rotates in the wrong direction, press the STOP button. Turn off the
disconnect switch (DIS-1) at the control panel and disconnect the power source.
Open the control panel and swap any two leads at the top of the disconnect
switch (DIS-1). Be sure to tight en the terminal connections securely.
Note: Manual operation is not satisfactory for production purposes and should only
be used to check the pelleti z er for proper operation. For pelletizers that have two
cylinders, do not operate both cylinders manually at the same time.
1. Turn on electrical power to the control panel.
2. Be sure the EMERGENCY STOP button is pulled out.
3. Turn the MAN/AUTO switch to the MAN (manual) position.
4. If the pelletizer has two cylinders, place the A/B/A&B switch to the desired cylinder, either A or B. Do not operate both cylinders manually at the same time.
5. Place the corresponding injection switch (A INJ or B INJ) to OFF.
6. Be certain that the compression cylinder is completely retracted and inject liquid
into the compression cylinder by holding the injection switch (A INJ or B
CO
2
INJ) in MAN (manual) position for 20 - 30 seconds, and then release the switch.
Note: The injection switch will not lock in the MAN (manual) position and
must be held for the duration of the liquid CO
injection
2
DO NOT INJECT LIQUID CARBON DIOXIDE INTO
THE CYLINDER UNLESS THE CYLINDER IS COMPLETELY RETRACTED. DOING SO WILL RESULT
IN CARBON DIOXIDE BEING INJECTED BEHIND
THE PISTON AND WILL RESULT IN DAMAGE TO
WARNING
7. Extrude dry ice through the extrusion die by holding the corresponding cylinder
switch (A CYL or B CYL) in EXT (extend) position until the cylinder fully extends, and then release the switch.
THE COMPRESSION CYLINDER, PISTON AND ROD.
4.1
OPERATION & MAINTENANCE
8. Hold the corresponding cylinder switch (A CYL or B CYL) in RET (retract) po-
sition until the cylinder fully retracts, and then release the switch.
9. To continue manual operation, repeat Steps 6 - 8.
2. Be sure the EMERGENCY STOP button is pulled out.
3. Depending on the length of liqui d supply lines from the carbon dioxide st orage
unit, it may be a long time before the machine starts making ice. Use the following procedure to get liquid to the machine and reduce the required start-up time.
NOTE: This procedure is not necessary on high capacity pelletizers. To start this
type of machine, simply press the start button. On all other types of pellet izers
manufactured by Tomco
starting automatic operation.
To pre-charge the pelletizer, turn the MAN/AUTO switch to the MAN
(manual) position. Place the corresponding injection switch (A INJ or B INJ)
to OFF. Be certain that the compression cylinder is completely retracted and in-
, it may be necessary to pre-charge the pelletizer before
2
ject liquid CO
(A INJ or B INJ) in MAN (manual) position until vapor begins to flow through
the extrusion die, and then release the switch. If the pelletizer has two cylinders and both will be used for automatic operation, repeat this process for the
other cylinder.
into the compression cylinder by holding the injection switch
2
DO NOT INJECT LIQUID CARBON DIOXIDE INTO
THE CYLINDER UNLESS THE CYLINDER IS COMPLETELY RETRACTED. DOING SO WILL RESULT
IN CARBON DIOXIDE BEING INJECTED BEHIND
THE PISTON AND WILL RESULT IN DAMAGE TO
WARNING
THE COMPRESSION CYLINDER, PISTON AND ROD.
4.2
Loading...
+ 60 hidden pages
You need points to download manuals.
1 point = 1 manual.