TORQUE NOTE: Max Torque 6 in-lbs. Use torque-controlled driver or wrench when installing lamp.
Wires and Functions
RED +12VDC/+24VDC BLACK Connect to chassis GROUND YELLOW Sync/Enter Programming Mode/Pattern Select BLUE Secondary Mode
Electrical
Input Voltage +12VDC/+24VDC Installation to be completed with wire rated for 125% of amperage draw.
2.5 amp in-line fuse recommended.
Current draw: 0.40 amps, in steady-burn mode at +12VDC/+24VDC
Selecting Flash Pattern: Primary Mode (YELLOW wire)
Apply +12VDC/+24VDC to the YELLOW wire and RED power wire at the same time. All LEDs will flash 3 times to indicate you have entered programming mode. Remove the YELLOW wire from +12VDC/+24VDC. Short (TAP) the YELLOW programming wire to select the Primary flash pattern. Note: After the unit flashes 3 times, the existing programmed Primary flash pattern will appear.
CYCLE FORWARD:
Intermittently short (TAP) the YELLOW wire once to +12VDC/+24VDC, then release. Repeat until the desired flash rate is selected.
CYCLE BACKWARD:
Intermittently short (TAP) the YELLOW wire twice to +12VDC/+24VDC in less than one second. Repeat until the desired flash rate is selected.
To RESET to flash rate #1 (Factory Default) and set for DIM flash mode:
While still in programming mode, apply +12VDC/+24VDC to YELLOW wire. Hold for approximately 3 seconds. All LEDs will flash 2 times. Release the YELLOW wire to indicate you have reset the unit to flash rate #1 (factory default for Primary mode).
1
04-30-18
IS0570-03
RECT-13LS4-x 4-wire Mini LED Series
Operational and Programming Instructions
Note: If unit was in normal brightness mode, the unit will now be in Dim mode. Repeat above to place unit back into normal brightness mode.
OPERATING MODE:
Disconnect YELLOW wire from power. Restore power to unit, RED wire only. Unit will now be in normal operation mode. Note: In normal operation mode, do not connect the YELLOW wire to power or ground.
Selecting Flash Pattern: Secondary Mode (BLUE + YELLOW wire)
Apply +12VDC/+24VDC to the BLUE wire, YELLOW wire and RED power wire at the same time. All LEDs will flash 4 times to indicate you have entered programming mode. Remove the YELLOW wire from +12VDC/+24VDC. Leave the BLUE wire connected to +12VDC/+24VDC. Short (TAP) the YELLOW programming wire to select the Secondary flash pattern. Note: After the unit flashes 4 times, the existing programmed Secondary flash pattern will appear.
CYCLE FORWARD: Intermittently short (TAP) the YELLOW wire once to +12VDC/+24VDC, then release. Repeat until the desired flash rate is selected.
CYCLE BACKWARD: Intermittently short (TAP) the YELLOW wire twice to +12VDC/+24VDC in less than one second. Repeat until the desired flash rate is selected.
To RESET to flash rate #7 (Factory Default) and SET for DIM flash mode:
While still in programming mode, apply +12VDC/+24VDC to YELLOW wire. Hold for approximately 3 seconds. All LEDs will flash 2 times. Release the YELLOW wire to indicate you have reset the unit to flash rate # 7 (factory default for Secondary mode). Note: If unit was in normal brightness mode, the unit will now be in Dim mode. Repeat above to place unit back into normal brightness mode.
OPERATING MODE:
Disconnect BLUE wire and YELLOW wire from power. Restore power to unit, RED wire only. Unit will now be in normal operation mode. Note: In normal operation mode, do not connect the YELLOW or BLUE wire to power or ground.