SPECIFICATIONS
SIZE 5.25” tall x 5.5” dia. x 2.0 lbs (133mm x 140mm x 0.9kg) NEMA 4X OPERATING TEMPERATURE -40 - +65 Degrees C INPUT VOLTAGE RANGE 10-28 V (DC/AC) NOMINAL INPUT VOLTAGE 12/24 V (DC/AC) INPUT CURRENT:
DC INPUT Steady State Mode Flashing Mode MAX MIN AVG 10VDC 486mA 1.1 A 2mA 263mA 12VDC 381mA 785mA 3mA 200mA 24VDC 194mA 385mA 7mA 98mA 28VDC 169mA 336mA 8mA 88mA
AC INPUT Steady State Mode Flashing Mode MAX MIN AVG 10VAC 613mA 735mA 193mA 472mA 12VAC 644mA 830mA 215mA 499mA 24VAC 352mA 622mA 181mA 347mA 28VAC 320mA 549mA 174mA 314mA
LIGHT SOURCE Single white LED with a total luminous output of 347 lm
WIRE CONNECTION Red + V (DC/AC) System on, Steady State
Black – V (DC/AC) Ground White + V (DC/AC) Flashing
IS0560-02
10/25/2016
OPERATION
To activate the unit in the PRIMARY - STEADYBURN MODE, connect the BLACK wire to –V (DC/AC) and connect the RED wire to +V (DC/AC). When in PRIMARY - STEADYBURN MODE, to change the unit to the SECONDARY - FLASH MODE, connect the white wire to +V (DC/AC).
PROGRAMMING PRIMARY & SECONDARY MODES
1) Remove power from unit.
2) Connect the White wire and Red wire together.
3) Restore power to the unit and wait approximately 3 seconds until the unit flashes 3 times. Remove the white wire only from +V (DC/AC), the unit will alternately demonstrate the Secondary - Flash Mode and Primary - Steadyburn Mode that will be displayed during operation. The Secondary - Flash Mode, followed by the Primary – Steadyburn Mode will be alternately demonstrated for approximately 4 seconds each. To select the next mode of operation, tap the white wire to +V (DC/AC). The unit will cycle to the next mode in the list below.
4) When you reach the desired mode of operation, remove power from the unit. When power is reapplied the unit will operate as last programmed.
Mode # Steadyburn Mode Secondary - Flash Mode
1 (Factory Setting) High Single - 60 FPM 2 OFF Single - 60 FPM 3 Low Single - 60 FPM 4 High Single - 150 FPM 5 OFF Single - 150 FPM 6 Low Single - 150 FPM 7 High Single - 375 FPM 8 OFF Single - 375 FPM 9 Low Single - 375 FPM 10 High Neobe - 75 FPM 11 OFF Neobe - 75 FPM 12 Low Neobe - 75 FPM 13 High Neobe - 150 FPM 14 OFF Neobe - 150 FPM 15 Low Neobe - 150 FPM 16 High Double - 125 FPM 17 OFF Double - 125 FPM 18 Low Double - 125 FPM 19 High Double - 250 FPM 20 OFF Double - 250 FPM 21 Low Double - 250 FPM