February, 1995 TOKO, Inc.
TK115xx
Page 5
10-15-94
SYMBOL PARAMETER TEST CONDITIONS MIN TYP MAX UNITS
I
CC1
Supply Current 1 VIN = 4.75 V, |O = 0 mA 500 900 µA
I
CC2
Supply Current 2 VIN = 3.3 V, |O = 0 mA 1.4 2.5 mA
I
CCS
Standby Supply Current VIN = 14 V, Output Off 0.2 2.0 µA
V
O
Output Voltage VIN = 4.75 V, |O = 30 mA 3.625 3.75 3.88 V
V
DROP
Voltage Dropout |O = 60 mA 0.13 0.35 V
I
O
Output Current VO = 3.45 V 100 130 mA
I
OR
Recommended 100 mA
Output Current
LinReg Line Regulation VIN = 4.75 V → 9.75 V 6.0 30 mV
LoaReg Load Regulation
IO = 0 to 30 mA, VIN = 4.75 V (Note 1) 20 55 mV
IO = 0 to 60 mA, VIN = 4.75 V (Note 1) 40 95 mV
RR Ripple Regulation 100 mVrms, f = 400 Hz, 55 dB
VIN = 5.25 V, IO = 10 mA
∆VO/∆TAVO Temperature VIN = 5.25 V, IO = 10 mA, ±0.3 mV/°C
Coefficient -20 °C ≤ TA ≤ 75 °C
V
NO
Output Noise Voltage 10 Hz ≤ f ≤ 100 kHz, IO = 10 mA 180 µVrms
I
B
Base Terminal Current VIN = 4.75 V 6 14 35 mA
Active High Control Terminal
I
HC
HC Terminal Current Output On, Connect LC & GND 2 40 µA
V
HC1
HC Terminal Voltage 1 Output On, Connect LC & GND 2.4 V
IN
V
V
HC2
HC Terminal Voltage 2 Output Off, Connect LC & GND 0 0.6 V
Active Low Control Terminal
I
LC
LC Terminal Current Output On, Connect HC & GND 35 120 µA
V
LC1
LC Terminal Voltage 1 Output On, Connect HC & GND 0 VIN-2.5 V
V
LC2
LC Terminal Voltage 2 Output Off, Connect HC & GND VIN-0.2 V
IN
V
TK11537 ELECTRICAL CHARACTERISTICS
Note 1: This is a pulse measurement where TJ is constant. The output change due to temperature is not included.