TOKO TK11380BUCB, TK11350BUCB, TK11350BMCL, TK11349BUCB, TK11349BMCL Datasheet

...
TK113xxB
VOLTAGE REGULATOR WITH ON/OFF SWITCH
FEATURES
High Voltage Precision at ± 2.0%
Active Low On/Off Control
Very Low Dropout Voltage 80 mV at 30 mA
Very Low Noise
Packages
Internal Thermal Shutdown
Short Circuit Protection
DESCRIPTION
The TK113xxB is a low dropout linear regulator with a built­in electronic switch. The device is in the ON state when the control pin is pulled to a low level. An external capacitor can be connected to the noise bypass pin to lower the output noise level to 30 µVrms.
An internal PNP pass transistor is used to achieve a low dropout voltage of 80 mV (typ.) at 30 mA load current. The TK113xxB has a very low quiescent current of 170 µA at no load and 1 mA with a 30 mA load. The standby current is typically 100 nA. The internal thermal shutdown circuitry limits the junction temperature to below 150 °C. The load current is internally monitored and the device will shutdown in the presence of a short circuit or overcurrent condition at the output.
APPLICATIONS
Battery Powered Systems
Cellular Telephones
Pagers
Personal Communications Equipment
Portable Instrumentation
Portable Consumer Equipment
Radio Control Systems
Toys
Low Voltage Systems
The TK113xxB is available in either 6 pin SOT-23L or 5 pin SOT-89-5 surface mount packages.
TK113XXB
GND
NOISE
GND
1
2 5
3
1
2
64V
6
5
IN
GND
V
OUT
V
OUT
GND
20Q
CONTROL
BYPASS
NOISE
BYPASS
V
4
IN
S
V
OUT
S
S
GND
Voltage Code
VOLTAGE CODE
20 = 2.0 V 21 = 2.1 V 22 = 2.2 V 23 = 2.3 V 24 = 2.4 V 25 = 2.5 V 26 = 2.6 V 27 = 2.7 V 28 = 2.8 V 29 = 2.9 V 30 = 3.0 V 31 = 3.1 V 32 = 3.2 V 33 = 3.3 V 34 = 3.4 V 35 = 3.5 V 36 = 3.6 V
37 = 3.7 V 38 = 3.8 V 39 = 3.9 V 40 = 4.0 V 41 = 4.1 V 42 = 4.2 V 43 = 4.3 V 44 = 4.4 V 45 = 4.5 V 46 = 4.6 V 47 = 4.7 V 48 = 4.8 V 49 = 4.9 V 50 = 5.0 V 55 = 5.5 V 60 = 6.0 V 80 = 8.0 V
ORDERING INFORMATION
TK113 B
PACKAGE CODE
M: SOT-23L U: SOT-89-5
C
Tape/Reel Code
TAPE/REEL CODE
L : Tape Left (SOT-23L) B : Tape Bottom (SOT-89-5)
Package Code
V
CONTROL
CONTROL
3
BLOCK DIAGRAM
S
S
IN
S
S
S
S
BANDGAP
REFERENCE
THERMAL
PROTECTION
S
+
S
S
SS
S
NOISE BYPASS
S
+
S
S
S
May, 1997 TOKO, Inc. Page 1
TK113xxB
ABSOLUTE MAXIMUM RATINGS
Supply Voltage ......................................................... 16 V
Output Current .................................................... 260 mA
Power Dissipation ...............................................(Note 1)
SOT-23L......................................................... 600 mW
SOT-89-5 ....................................................... 900 mW
TK113XXB ELECTRICAL CHARACTERISTICS
Test conditions: T
SYMBOL PARAMETER TEST CONDITIONS MIN TYP MAX UNITS
= 25 °C, unless otherwise specified.
A
Reverse Bias............................................................ 10 V
Storage Temperature Range ................... -55 to +150 °C
Operating Temperature Range ...................-30 to +80 °C
Voltage Range ............................................ 1.8 to 14.5 V
Junction Temperature ........................................... 150 °C
I
Q
I
STBY
V
O
Quiescent Current I
= 0 mA, Except I
OUT
CONT
170 250 µA Standby Current VIN = 8 V, at output off 0.1 µA Output Voltage I
= 30 mA See table 1 V
OUT
Line Reg Line Regulation VO 5.5 V (Note 2) 3.0 20 mV Load Reg Load Regulation I
V
DROP
I
OUT
Dropout Voltage I Continuous Output Current I
= 1 mA 60 mA (Note 3) 6 30 mV
OUT
I
= 1 mA 100 mA (Note 3) 18 90 mV
OUT
= 60 mA 0.12 0.24 V
OUT OUT
when V
drops 0.3 V 150 mA
OUT
from VO (typ) (Note 3)
RR Ripple Rejection f = 400 Hz, CL= 10 µF, CN = 0.1 µF55 dB
VIN = V
+ 1.5 V, I
OUT
= 30 mA,
OUT
(Note 4)
V
NO
Output Noise Voltage 10 Hz f 80 KHz, 30 µVrms VCN = V
+ 1.5 V, I
OUT
= 60 mA,
OUT
CL = 10 µF, CN = 0.1 µF, (Notes 4,5)
I
OUT (PULSE)
V
Noise Bypass Terminal Voltage 1.25 V
REF
Pulse Output Current 5 ms pulse, 12.5% duty cycle 200 mA
Control Terminal Specification
I
CONT
V
CONT
VO/T
A
Control Current Output on, V Control Voltage
Output Voltage Temperature I
Output on VIN-1.8 V Output off
= 10 mA 0.09 mV/°C
OUT
= 1.8 V 12 35 µA
CONT
VIN-0.6
V
Coefficient
Note 1: When mounted as recommended. Derate at 4.8 mW/°C for SOT-23L and 6.4 mW/°C for SOT-89-5 packages when ambient
temperatures are over 25 °C. Note 2: For Line Regulation V Note 3: Refer to Definition of Terms. Note 4: Ripple Rejection and noise voltage are affected by the value and characteristics of the capacitor used.
Note 5: Output noise voltage can be reduced by connecting a capacitor to a noise pass terminal. Gen. Note: Parameters with min. or max. values are 100% tested at T
> 5.6 V, Typ and Max values are 15 and 40 mV.
O
= 25 °C.
A
Page 2 May, 1997 TOKO, Inc.
TK113xxB ELECTRICAL CHARACTERISTICS (Table 1)
TK113xxB
Output Voltage VIN Max V
Voltage Code Voltage
2.0 V 20 1.94 V 2.06 V 3.0 V
2.1 V 21 2.04 V 2.16 V 3.1 V
2.2 V 22 2.14 V 2.26 V 3.2 V
2.3 V 23 2.24 V 2.36 V 3.3 V
2.4 V 24 2.34 V 2.46 V 3.4 V
2.5 V 25 2.44 V 2.56 V 3.5 V
2.6 V 26 2.54 V 2.66 V 3.6 V
2.7 V 27 2.64 V 2.76 V 3.7 V
2.8 V 28 2.74 V 2.86 V 3.8 V
2.9 V 29 2.84 V 2.96 V 3.9 V
3.0 V 30 2.94 V 3.06 V 4.0 V
3.1 V 31 3.04 V 3.16 V 4.1 V
3.2 V 32 3.14 V 3.26 V 4.2 V
3.3 V 33 3.24 V 3.36 V 4.3 V
3.4 V 34 3.335 V 3.465 V 4.4 V
3.5 V 35 3.435 V 3.565 V 4.5 V
3.6 V 36 3.535 V 3.665 V 4.6 V
Max Test
OUT
Output Voltage VIN Max V
Voltage Code Voltage
3.7 37 3.630 3.770 4.7
3.8 38 3.725 3.875 4.8
3.9 39 3.825 3.975 4.9
4.0 40 3.920 4.080 5.0
4.1 41 4.020 4.180 5.1
4.2 42 4.120 4.280 5.2
4.3 43 4.215 4.385 5.3
4.4 44 4.315 4.485 5.4
4.5 45 4.410 4.590 5.5
4.6 46 4.510 4.690 5.6
4.7 47 4.605 4.795 5.7
4.8 48 4.705 4.895 5.8
4.9 49 4.800 5.000 5.9
5.0 50 4.900 5.100 6.0
5.5 55 5.390 5.610 6.5
6.0 60 5.880 6.120 7.0
8.0 80 7.840 8.160 9.0
Max Test
OUT
May, 1997 TOKO, Inc. Page 3
TK113xxB
TEST CIRCUITS
SOT-23L SOT-89-5
I
IN
V
IN
V
CONT
+ _
A
+ _
+
V
I
CONT
CONT
IN
1
23
1 µF
S
A
V
TYPICAL PERFORMANCE CHARACTERISTICS
OUTPUT VOLTAGE RESPONSE
(OFF ON)
CL = 2.2 µF
Cn = 0.01 µF
V
OUT
456
SS
+
Noise Bypass
0.1 µF
V
O
S
I
2.2 µF
V
O
Transient Response
V
IN
CONT
+
TA = 25 °C unless otherwise specified
VO (5 mV/Div)
113XXB
Rs
1 µF
C
P
0.1 µF
LOAD REGULATION
+
V
IN
V
V
OUT
CL = 10 µF
to 0.22
V
S
I
O
O
SS
+
2.2 µF
NOISE
BYPASS
0.1 µF
•Connect pin 5 to ground for heat sink
I
V
IN
IN
+
1
456
23
CONT
I
CONT
1.0 µF
A
SHORT CIRCUIT CURRENT
5
4
A
+ _
V
IN
S
+
V
V
CONT
_
VO TYP
Cn = 0.1 µF
I
= 30 mA
LOAD
T=0 200 400 600
TIME (µS)
OUTPUT VOLTAGE vs. INPUT
VOLTAGE
V
(25mV/Div)
OUT
IO = 0 mA
IO = 30 mA
IO = 50 mA
IO = 90 mA
V
IN
= V
OUT
0
VIN (V) (50 mV/Div)
800
TYP
OUT
V
VO TYP
3
(V)
O
V
2
1
0 50 100
I
(mA)
OUT
LINE REGULATION
0
0 300
150
IO (mA)
OUTPUT CURRENT vs.
DROPOUT VOLTAGE
50 mV/Div
0
-100
(mV)
-200
DROP
-300
V
-400
020
10
V
(V)
IN
0 200
100
IO (mA)
Page 4 May, 1997 TOKO, Inc.