Tokheim Premier C Series Manual

Site Preparation Manual
5869
V ersion
M AY 2000
3.0
Date of issue for original version and subsequent versions:
Version 1.0.............July 1999
Version 2.0.............March 2000
Version 3.0............May 2000
Page Version
No. No.
Cover ................................ 3.0
Manual History Page ........ 3.0
Read Me First ................... 1.0
i – ii................................... 3.0
iii – iv................................ 1.0
1-1..................................... 1.0
NOTE: If entries are shown in bold Italics on this page, they represent new
page(s) found in this latest version. Previous version numbers are contained
within this latest version printing. Use this Manual History page as a guide.
Page Version
No. No.
2-5..................................... 1.0
2-6 – 2-8 ........................... 3.0
2-9 – 2-11 ......................... 1.0
2-12 – 2-14 ....................... 3.0
2-15 – 2-16 ....................... 3.0
3-1..................................... 3.0
Page Version
No. No.
3-4 – 3-5 ........................... 1.0
3-6..................................... 2.0
3-7..................................... 1.0
3-8 – 3-21 ......................... 3.0
3-22 – 3-31 ....................... 3.0
4-1 – 4-3 ........................... 1.0
1-2..................................... 3.0
2-1 – 2-4 ........................... 3.0
3-2..................................... 1.0
3-3..................................... 2.0
4-4..................................... 3.0
Index 1 –– Index 3............ 3.0
Copyright © 1999 Tokheim Corporation. All rights reserved.
The information contained in this manual is copyrighted by Tokheim Corporation and is for the exclusive use of Tokheim’s Authorized Service Representatives, Distributors, and customers, who are authorized to make copies for use in their business. No part of this manual may be reproduced or transmitted in any form by any other person or persons without written permission of Tokheim Corporation.
Trademarks: INSIGHT
is a trademark of Tokheim Corporation. MaxVac® is
a registered trademark of Tokheim Corporation
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 3.0 July 1999 Rev. 05/12/00
READ ME FIRST
Equipment Inspection
When the dispensers arrive at the installation site, the unpacked units should be inspected for possible shipping damage. If damage is evident, it must be reported to the carrier. Shipping damage is not covered under the Tokheim warranty policy.
After unpacking and prior to installation, the delivered equipment should be inspected to insure that all the required materials are on hand, and the dispensers have all the ordered options and markings. Compare the model number on the dispenser model/serial plate to the model number notation information in section 1 of this manual. If discrepancies in dispenser options and markings are determined, contact Tokheim World Wide Order Support at 219-470-4640.
Checkout f orms can be ordered at no charge thro ugh: T okheim Service P arts PO Box 663 Fremont, IN 46737 Phone (219) 470-4710 Fax 1-800-866-1999
Start-up Checklists
Proper installation of today's sophisticated electronic dispensing systems is essential to ensure trouble-free performance. Therefore, Tokheim has established inspection and checkout procedures to be followed to verify proper equipment installation.
A properly completed checkout form (Form 4861) must be submitted by an authorized Tokheim distributor to begin the equipment warranty. A Tokheim certified technician must perform the checkout/start-up. Checkout forms must be submitted within 15 days after checkout and start-up completion in order to be paid. For more information on Tokheim's checkout and start-up policy, see Form 5004, "Warranty Registration and Checkout Procedures for Tokheim Equipment."
Premier C Series Dispensers Site Preparation Manual T okheim Corporation Form 5869 Version 1.0 July 1999
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual
Form 5869 Version 1.0 July 1999
CONTENTS
1 Introduction
Scope ............................................................................................ 1-1
Conventions used in this Manual ................................................... 1-1
Document-on-Demand .................................................................. 1-2
Related Documents ....................................................................... 1-2
2 Planning and Preparation
Outline Drawings
H322C-RB3 & RB5, H322C-SB3 & SB5 ........................................ 2-2
H322C-R, H322C-S....................................................................... 2-3
H324C-R, H324C-S....................................................................... 2-4
H422C-R, H422C-RB3 & RB5 ....................................................... 2-5
H412C-R, H424C-R, H424C-RB3 & RB4, H424C-SB3+1 ............. 2-6
H413C-R, H426C-R, H413C-REB, H426C-REB, H426C-S ........... 2-7
H414C-R, H428C-R, H428C-REB, H428C-SEB............................ 2-8
Foundation Plans
H300C Remote Dispenser Models ................................................ 2-9
H400C Remote Dispenser Models (3 product) ............................ 2-10
H400C Remote Dispenser Models (4 product) .............................2-11
H300C Suction Dispenser Models ............................................... 2-12
H400C Suction Dispenser Models ............................................... 2-13
Moving the Dispenser
Moving the Dispenser .................................................................. 2-14
Determining Side A on the Dispenser .......................................... 2-15
Underground Piping Requirements
Underground Piping for Vapor Return Lines (MaxV ac) ................ 2-16
Emergency Shut-off Valves (Impact or Shear V alves) ................ 2-16
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 3.0 July 1999 Rev. 05/12/00 i
CONTENTS
3 Electrical Site Requirements
General Wiring Requirements ....................................................... 3-2
Grounding Requirements............................................................... 3-3
System Requirements ................................................................... 3-4
System Power Considerations....................................................... 3-5
Remote Dispenser Current Requirements..................................... 3-6
Suction Dispenser Current Requirements ..................................... 3-8
Peripheral Devices Current Requirements .................................. 3-10
Determining Wire Gauge over Distance ...................................... 3-10
Determining Number of Wires Required .......................................3-1 1
Determining Conduit Size Required............................................. 3-12
Electrical Conduit Requirements.................................................. 3-13
Tokheim Debit System (TDS)
& INSIGHT DPT Cable Specifications ......................................... 3-14
T ypical Installation Diagrams
Remote Dispenser without Hose Controller........................... 3-15
Remote Dispenser with Hose Controller ............................... 3-16
Suction Dispenser without Hose Controller ........................... 3-17
Suction Dispenser with Hose Controller ................................ 3-18
Wiring Diagrams
Remote Dispenser, Stand-Alone........................................... 3-19
Remote Dispenser with Console Control............................... 3-20
Remote Dispenser with DPT and Console Control................ 3-21
Suction Dispenser with DPT and Console Control ................ 3-22
Suction Motor / Junction Box - 120 VAC, 50/60 HZ............... 3-23
Suction Motor / Junction Box - 240 VAC, 50/60 HZ............... 3-24
Suction Motor / Junction Box - 380/220 VAC, 3 Phase.......... 3-25
Suction Motor Wiring - 120/240 VAC, 50/60 HZ .................... 3-26
Suction Motor Wiring - 220/380 VAC, 50/60 HZ .................... 3-27
Sample Main & Sub Panel Wiring Diagram.................................. 3-28
Sample Electrical System Wiring Diagram................................... 3-30
4 Glossary
A — Z .....................................................................................4-1 – 4-4
Index .....................................................................Index-1 – Index-2
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual ii Form 5869 Version 3.0 July 1999 Rev. 05/12/00
DISCLOSURE NOTICE
This document contains information proprietary to Tokheim Corporation. The data contained herein, in whole or in part, may not be duplicated, used, or disclosed outside the recipient or purchaser for any purpose other than to evaluate or operate the equipment described within the document.
DISCLAIMER
ALTHOUGH TOKHEIM CORPORATION HAS ATTEMPTED TO COMPILE THE MATERIAL IN THIS MANUAL WITH ACCURACY, NEITHER IT, ITS EMPLOYEES, NOR ITS AGENTS CAN MAKE ANY WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, WITH RESPECT TO THE LIABILITY WITH REGARD TO THE USE OF THIS MATERIAL OR ASSUME ANY LIABILITY FOR DAMAGES RESULTING FROM THE USE OF ANY INFORMATION, APPARATUS, METHOD, OR PROCEDURE DESCRIBED IN THIS MANUAL.
!!! FCC W ARNING !!!
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and has been found to comply as a class A device with Part 15, Subpart J of the FCC rules at date of manufacture.
IMPORTANT
THIS EQUIPMENT MUST BE INSTALLED AND USED IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THE NATIONAL ELECTRICAL CODE (NFPA NO. 70) AND THE AUTOMOTIVE AND MARINE SERVICE STATION CODE (NFPA 30A).
It is the owners and operators responsibility to ensure that the proper warning signs are posted per the current edition of NFPA 30A, Code #9-9. These include, but are not limited to,
• “STOP MOTOR
• “NO SMOKING
• “WARNING IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE INTO
UNAPPROVED CONTAINERS”.
TOKHEIM DISPENSERS SHALL NOT BE USED FOR DIRECT FUELING OF AIRCRAFT WITHOUT FILTERS, SEPARATORS, AND OTHER EQUIPMENT NECESSARY TO ENSURE PRODUCT PURITY.
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 1.0 July 1999 iii
Safety Information
!
The following requirements are mandatory and shall be followed when installing, using, or working around Tokheim equipment. These hazards or unsafe practices may result in death or severe injury to persons, or damage to equipment or property.
DANGER! FIRE AND EXPLOSION HAZARD
No Smoking - Never permit
smoking in the dispensing area. Sparks and embers from burning cigarettes or pipes can set fuels and their vapors on fire.
WARNING! FIRE AND ELECTRICAL HAZARD
High Voltage - To reduce the
risk of electrical shock when servicing, turn off all power to all equipment. In submersible pump applications, turn off power to the submersible pump and any other dispensers which use that submersible pump. AC power can feed back into a shut off dispenser when dispensers share a common submersible pump or starter relay.
No Flames - Never permit open flames in the dispensing area. Flames from lighters, matches, welding torches, etc. can set fuels and their vapors on fire.
Stop Button - The Stop Button may not shut off all power to the dispenser. Be sure all employees are trained how to shut off all power to the system in case of emergency. Code #4-1.2 of the current edition of NFPA 30A requires that:
“A clearly identified and easily accessible switch(es) or circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.”
Additionally, Code #9-4.5 of the current edition of NFPA 30A requires that:
“Emergency controls specified in 4-1.2 [listed above] shall be installed at a location acceptable to the authority having jurisdiction, but controls shall not be more than 100 ft. (30m) from dispensers.”
Dispense In Approved Containers -
Dispense gasoline and other petroleum products into
approved containers that are on the ground. To prevent static discharge, never dispense gasoline into a portable container that is in or on a vehicle, including trucks. Always use Tokheim approved and UL Listed hoses and nozzles with this dispenser.
WARNING! SERVICE HAZARD
Turn Power Off - Before
servicing, always turn off all power to the dispenser and submerged pumps at the master panel. Close any impact valve before performing any maintenance or service to the dispenser, including the changing of fuel filters or strainers.
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual iv Form 5869 Version 1.0 July 1999
Block Islands - Block islands so no vehicle can pull up to the dispenser being worked on. Unauthorized people or vehicles in the work area are dangerous.
Clean Up Spills - Promptly clean up product spills on the driveway. Use an absorbent recommended by regulatory agencies. Dispose of absorbent as required by regulatory agencies.
Section 1: Introduction
Introduction
!
WARNING All installations must conform to NFP A (National Fire Protection Agency) 30, 30A, 70 and applicable National, State, and Local code requirements. Otherwise, severe injury or death could result.
Scope
This manual is provided to assist those who prepare the site for installation of Tokheim equipment and install Tokheim dispensers onto the islands. Please read, understand, and follow this manual and all applicable NFPA requirements before installing the equipment.
Failure to install the dispensers per Tokheim specifications may void the Tokheim Warranty. Express permission must be obtained for alternative wiring schemes.
Installers having questions pertaining to site preparation or installing Tokheim dispensers should contact their Tokheim distributor.
Conventions used in this Manual
!
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
!
WARNING
WARNING indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
!
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate personal injury or property damage.
Tips provide useful information that can make your work easier.
Notes supply information that emphasizes or supplements important points in the text. Notes may also refer you to related information elsewhere in the manual.
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 1.0 July 1999 1-1
Introduction
DOCUMENT-on-DEMAND
Tokheim has a FAX-back service that allows its customers to retrieve documents 24-hours-a-day , 7-days-a-week. The documents that are available consist mainly of Dispenser Outline Drawings, Dispenser Foundation Plans, Wiring Diagrams, and other related Technical Information.
To access this service, dial (219) 484-1864 and follow the automated instructions to retrieve your document. If you do not know the number of the document you want, press 9999 and an Index of all available documents will be faxed to you.
Foundation Plans:
0272 H413C-R, H426C-R, H422C-R, H426C-REB, H422C-RB3/4/5,
H413C-REB
0273 H412C-R, H424C-R, H424C-RB3/4, H414C-R, H428C-R,
H428C-REB
0274 H311C-R, H312C-R, H322C-R, H324C-R, H31 1C-RB3/5,
H322C-RB3/5
Wiring Diagrams:
Related Documents
These documents can be ordered from: Tokheim Service Parts PO Box 663 Fremont, IN 46737 Phone (219) 470-4710 Fax 1-800-866-1999
0107 Model 67 Interface Box
PREMIER C Parts Manual, Form 5866
PREMIER C Installation Manual, Form 5870
PREMIER C Technical/Reference Manual, Form 4817A
The ONE Manual (Care of Your Pumps), Form 1680B.
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 1-2 Form 5869 Version 3.0 July 1999 Rev. 05/12/00
Planning and Preparation
Section 2: Planning and Preparation
Section 2 Contents
Outline Drawings
H322C-RB3 & RB5, H322C-SB3 & SB5 ....................................... 2-2
H322C-R, H322C-S....................................................................... 2-3
H324C-R, H324C-S....................................................................... 2-4
H422C-R, H422C-RB3 & RB5....................................................... 2-5
H412C-R, H424C-R, H424C-RB3 & RB4, H424C-SB3+1............. 2-6
H413C-R, H426C-R, H413C-REB, H426C-REB, H426C-S........... 2-7
H414C-R, H428C-R, H428C-REB, H428C-SEB ........................... 2-8
Foundation Plans
H300C Remote Dispenser Models ................................................ 2-9
H400C Remote Dispenser Models (3 product)............................ 2-10
H400C Remote Dispenser Models (4 product)............................. 2-11
H300C Suction Dispenser Models............................................... 2-12
H400C Suction Dispenser Models............................................... 2-13
Moving the Dispenser
Moving the Dispenser.................................................................. 2-14
Determining Side A on the Dispenser ......................................... 2-15
Underground Piping Requirements
Underground Piping for Vapor Return Lines (MaxV ac)................ 2-16
Emergency Shut-off Valves (Impact or Shear V alves)................ 2-16
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 3.0 July 1999 Rev. 05/12/00 2-1
Planning and Preparation
Outline Drawing
H322C-RB3 & RB5, H322C-SB3 & SB5
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 2-2 Form 5869 Version 3.0 July 1999 Rev. 05/12/00
741645
Outline Drawing
H322C-R, H322C-S
Planning and Preparation
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 3.0 July 1999 Rev. 05/12/00 2-3
741644
Planning and Preparation
Outline Drawing
H324C-R, H324C-S
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 2-4 Form 5869 Version 3.0 July 1999 Rev. 05/12/00
741643
Outline Drawing
H422C-R, H422C-RB3 & RB5
Planning and Preparation
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 1.0 July 1999 2-5
741640
Planning and Preparation
H412C-R, H424C-R, H424C-RB3 & RB4, H424C-SB3+1
Outline Drawing
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 2-6 Form 5869 Version 3.0 July 1999 Rev. 05/12/00
741641A
Planning and Preparation
Outline Drawing
H413C-R, H426C-R, H413C-REB, H426C-REB, H426C-S
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 3.0 July 1999 Rev. 05/12/00 2-7
741639
Planning and Preparation
H414C-R, H428C-R, H428C-REB, H428C-SEB
Outline Drawing
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 2-8 Form 5869 Version 1.0 July 1999
741642A
Planning and Preparation
422779A
Remote Dispensers
Foundation Plan - H300C Models
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 1.0 July 1999 2-9
Planning and Preparation
422774A
Remote Dispensers - 3 Product
Foundation Plan - H400C Models
Tokheim Corporation Premier C Series Dispensers Site Preparation Manual 2-10 Form 5869 Version 1.0 July 1999
Planning and Preparation
422775A
Remote Dispensers - 4 Product
Foundation Plan - H400C Models
Premier C Series Dispensers Site Preparation Manual Tokheim Corporation Form 5869 Version 1.0 July 1999 2-11