Date of print: 2016.10
Date of publication: 2016.9
APPLICATIONS OF THIS FIRE PUMP
USAGE
TOHATSU fire pumps ” V20E(S) / V20D2(S)” are manufactured for use in fire fighting
operations.
These portable fire pumps are intended only for fire fighting activities in collaboration
with general public fire extinguishing equipment.
Using it for other applications is regarded as being used for improper purposes.
The manufacturer of these fire pumps bears no responsibility for any damages that may
result from modification of the fire pump without prior permission from the manufacture,
improper use of the fire pump, or use of the fire pump for applications other than those
stated above.
Note that use these fire pumps for applications other than those stated above can result
in personal injury or damage to the equipment.
Using these fire pumps within the range of intended uses implies that the user should
follow the instructions provided by the manufacturer relevant to operation, servicing and
maintenance.
Intended people
All persons who operate, services or maintains this fire pump must read and understand
the following items:
・ Owner’s manual
・ Safety-related instructions described in each chapter or section of owner’s manual.
The portable pump should be operated by only persons who received training as
operators of fire engines along with each country’s (region’s) regulations.
The range of personal responsibility and su pe rvision must be strictly defined by the user.
If a person does not have adequate professional knowledge which is required for his/her
assignment, he/she must undergo relevant training or receive appropriate instructions
from an individual who is actually knowledgeable in operation of this fire pump.
A person who does not have enough knowledge is not permitted to operate this fire
pump.
When using this fire pump, conditions under which an explosion may occur are not
considered.
CAUTION
Keep this manual in a safe place for further reference.
Operators of this fire pump must always refer to all the relevant
manuals in order to avoid errors, personal injuries and
equipment damage when operating the portable fire pump, and
to maintain faultless operation.
Arrange owner’s manual so that operators can refer to them
where they operate the fire pump.
INTRODUCTION
Thank you for purchasing the TOHATSU Fire Pump.
This fire pump has passed a range of quality assurance standards.
Owner’s manual
This portable fire pump complies with relevant laws and regulations.
This manual includes a description for operation and maintenance. Before using this fire
pump, be sure to read and understand this manual thoroughly.
Engine operation
This manual also includes a description for operation and maintenance of the engine.
This manual is an important item that goes with your portable fire
NOTE
This manual should accompany this fire pump if sold to another
pump.
person.
MANUFACTURER AND AFTER-SALES SERVICE ADDRESS
Before using this fire pump, write down the serial number in the following boxes.
This will be useful when you inquire about servicing, repairs and genuine parts.
TOHATSU CORPORATION
Address :3-5-4 Azusawa, Itabashi-ku, Tokyo, JAPAN
FAX :+81-3-3966-2951
Phone :+81-3-3966-3137
Serial Number
(Identification Number)
The pump serial number is marked on the pump casing.
GENERAL SAFETY INFORMATION
Overview
Before operating the TOHATSU fire pump thoroughly read
this manual. Understanding proper operation procedures
including “DANGER”,”WARNING”,“CAUTION” and “NOTE”.
These notices are designed to bring attention to very
important information necessary to ensure safe, trouble free
operation.
Warning sign
Meaning
This sign is used for safety-related instructions in this
manual.
Be sure to follow all safety-related instructions, otherwise
personal injury may occur.
Signal words
Failure to observe will result in severe personal injury or
death, and possibly property damage
Failure to observe could result in severe personal injury or
death.
Failure to observe could result in personal injury or property
damage.
・ This instruction provides special information to facilitate the use or maintenance of the
pump or to clarify important points.
・ For attaching position of the warning label, refer to the contents “3 LABELS”.
・ Warning labels should be read clearly at any time.
If the display of the warning label becomes difficult to be read, it was almost
come off, you must replace paste immediately.
Safety-related instructions and warning signs
Read and follow the safety-related instructions described in this manual and all warning
signs on the portable fire pump thoroughly.
Always keep the warning signs in a legible condition. If any warning sign becomes
illegible or detached, replace it immediately.
Transporting the portable fire pump
When transporting the portable fire
pump, assign one person per handle.
Also, when you transport the portable
fire pump, it should be transported
holding the handle firmly.
There is a risk of injury to the leg by fall.
Durability of protection
When you purchase a new pump, it is placed in packing box and protected.
Storage of pump after transportation
Keep the pump away from high humidity, and place it on a horizontal plane.
Disposal of packing box
Dispose the packing box by following the environmental laws.
Wear proper hearing protection during
operation.
Exhaust gas
Exhaust gas emitted from the engine contains carbon monoxide
(CO) etc. that may seriously affect human health.
Do not operate the engine in a room, car, warehouse, tunnel or other
closed locations that have poor ventilation.
Mortal danger due to carbon monoxide (CO) poisoning.
Handling of fuel
Exercise care when handling fuel.
Failure to do so may cause fire.
Do not bring any flames near fuel.
Stop the engine before refueling fuel.
Do not smoke while refueling fuel.
Do not refill fuel in an enclosed room to a voidan explosion by fuel fumes.
If fuel spills, wipe it with a cloth or other material, and dispose of it according to relevant
laws and regulations.
Safety devices
Before operating this portable fire pump, be sure to check that all the
safety devices have been installed in the appropriate positions.
Before removing the safety devices, turn the main switch off.
Protective clothing
Protective equipment
During fire extinguishing training or normal fire fighting
services, wear normal protective clothing and equipment to
protect your body.
Servicing and maintenance of this fire pump must be carried out by
only persons who have professional knowledge, who are familiar with
the device and who understand laws and regulations regarding safety
and accident prevention.
Before starting maintenance work, turn the main switch off to stop the
engine.
Disconnect the negative terminal of the battery.
Before starting maintenance work, securely place the portable fire pump on the ground.
Do not touch the exhaust pipe, the muffler and the other engine parts until these parts
will be cold enough. These parts could be very hot and will cause severe burns.
Safety devices
After protection devices (such as muffler guard) have been
disassembled as part of servicing and maintenance work,
immediately install them back to their original locations,
making sure that they are in safe secure condition.
Check the portable fire pump visually and functionally on a
regular basis.
If you find any faulty device or equipment, remove it
immediately, and repair or replace it, if necessary.
Failure to do so may cause an accident.
After it has been repaired or replaced, make sure that it
functions correctly.
Electrical equipment
Only expert electricians or trained staff members should
handle electrical equipment.
When removing the battery cable from the electrical
equipment, always disconnect the negative (-) cable first.
When installing the bat tery cable, be sure to connect the
positive (+) cable first before co nnecting the negative (-).
Do not place any metal on the top of or around the battery.
Doing so many causes a short circuit.
Use a fuse with the same specifications as the original one
when replacing it. Using a fuse that has a greater capacity
than the rated value may damage the equipment.
While engine is running, do not touch the high
voltage ignition wire attached to spark plug. This wire
carries very high voltage which will cause injury and
bodily harm.
Check the electrical equipment of the fire pump on a regular basis.
Battery
Follow any safety-related instructions shown on the battery.
The battery can generate flammable hydrogen gas that may cause an explosion.
Do not charge the battery in closed location.
Do not smoke around the battery.
The battery electrolyte is caustic and may cause personal
Injuries.
・ Always wear protective clothing.
・ Always wear protective gloves.
・ Always wear protective glasses.
・ Do not tilt the battery.
Doing so may cause the battery electrolyte to leak out
from the vent hole.
Disposal
Dispose of disused batteries according to relevant laws
and regulations.
Genuine parts
When replacing parts for servicing and maintenance of the
portable fire pump, only use Tohatsu genuine parts.
If genuine Tohatsu parts and accessories are not used it
may adversely affect the functioning and safety of the fire
pump. Use genuine Tohatsu parts only.
Tohatsu bears no responsibility for any personal injuries or equipment damage that may
result from use of parts or accessories obtained from outside sources.
Environmental protection measures
Dispose of oil, fuel, batteries, etc. according to relevant
environmental laws.
Do not dump waste into the ground, water, or sewerage.
Store fuel only in the specified container.
When disposing of parts, follow the correct disposal
procedure.
Water-prohibiting substance
Do not discharge water to water-prohibited substance.
Use of water
Do not pump combustible liquids, chemical or caustic liquids.
Customer Service
If any problems occur during servicing and maintenance
work of the portable fire pump, contact our Customer
Service.
Address : 3-5-4 Azusawa, Itabashi-ku, Tokyo,
Japan
Fax : +81-3-3966-2951
Phone : Service +81-3-3966-3380
/ Email tohatsu-pservice@tohatsu.co.jp
Overseas section fire protection sales department
Model V20E V20ES
Description Portable fire pump
Engine
Manufacturer TOHATSU CORPORATION
Model T66C
Type 2-stroke, air-cooled spark ignition engine
Bore ×Stroke 66 mm × 58 mm (2.60 in × 2.28 in)
Number of Cylinder 1
Piston displacement 198 ml
Authorized output 11.7 PS (8.6kW)
Fuel type Unleaded petrol RON91
Fuel tank capacity 3.5 L (0.92 gal)
Fuel consumption 4.9 L/h (1.29 gal/h)
Ignition C.D.I.
Spark plug NGK B7HS
Starting system Manual Starter motor and Manual
Model V20D2 V20D2S
Description Portable fire pump
Engine
Manufacturer TOHATSU CORPORATION
Model T66C
Type 2-stroke, air-cooled spark ignition engine
Bore × Stroke 66 mm ×58 mm (2.60 in × 2.28 in)
Number of Cylinder 1
Piston displacement 198 ml
Authorized output 11.7 PS (8.6kW)
Fuel type Unleaded petrol RON91
Fuel tank capacity 3.5 L (0.92 gal)
Fuel consumption 4.9 L/h (1.29 gal/h)
Ignition C.D.I.
Spark plug NGK B7HS
Starting system Manual Starter motor and Manual
JIS-B-9912 dimensions of screwed type
coupling for fire hose 2-1/2”(
inch, thread angle 55°)
0.65 m3/min at 0.5 MPa
155 USG/min at 75 psi
0.40 m3/min at 0.7 MPa
115 USG/min at 100 psi
Aluminum alloy
Aluminum alloy
4
φ82.5,5 threads per
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
1
Performance Curve
V20ES
1
SPECIFICATIONS
1
22
9
10
13
14
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
15
16
17
18
5
1
9
10
13
14
15
16
17
18
Performance Curve
V20D2S
1
SPECIFICATIONS
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
6
(
)
1
9
10
13
14
15
16
17
18
2
OPERATING DEVICE
Discharge valve handle
Discharge port
adaptor (opt)
Priming lever
・Main switch (For Model S)
・Stop switch (For Model M)
Pressure gauge
(Compound pressure
gauge)
Vacuum gauge
(Compound pressure
gauge)
Socket
Oil pot
(For V20E(S))
Fuse
For Model S
Spark plug cap
Fuel tank cap
Governor oil
gauge
Drain valve
Battery
(For Model S)
Muffler
(Inside of muffler cover)
Muffler cover
Exhaust pipe
Vacuum pump drain pipe
Fuel gauge
Carburetor
Throttle dial
Recoil starter handle
Fuel valve
Fuel drain knob
Fuel tank
Carrying handle
Fuel drain pot
Vacuum pump
Strainer cap
for Vacuum
pump
Suction port cap
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
7
1
9
10
13
14
15
16
17
18
3
LABELS
WARNING & CAUTION
Fuel danger label
Exhaust gas warning label
Muffler caution label
Instruction label
Spark plug & High voltage
caution label
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
8
1
9
10
13
14
15
16
17
18
4
OPERATING PRECAUTIONS
Installing pump
The fire pump must be installed on level ground. Otherwise, an
accident may occur.
If the fire pump should be installed on uneven ground, it must
be secured.
Place the pump as near as possible to water source, and water
suction height as low as possible.
When putting the porta ble fire pum p down t o t he gr ound, put it gentl y
and horizontally.
In case of the inclined location or u neven g rou nd, mak e sure that t h e
water suction hose is lower than the suction port of the pump.
In case of the suction hose is put undulated, air can be left easily in
the hose, and possibly cause suction inability when the water
discharge valve is opened.
In case of the suction inability due to air remaining in the suction
hose, set the water discharge valve half-opened, and operate
vacuum pump until water is discharged continuously. (for 3 to 5
seconds from beginning of water discharge)
Be sure to install strainer and basket on the end of suction hose. If
the pump may suck sand or mud of the bottom of water source,
place sheet below the basket.
Strainer and basket of suction hose should be placed more than 3 00
mm (11.8 in) below water surface to prevent suck of air.
Discharge hose should be arranged not to be bent.
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
9
1
9
10
4
OPERATING PRECAUTIONS
When installing the portable pump in the vehicle, place the
vehicle on a level place, and install the pump.
When transporting the portable fire pump, assign one person
per handle. Also, when you transport the portable fire pump, it
should be transported holding the handle firmly.
Do not touch the exhaust pipe and the muffler
while the engine is running, or for more than 10
minutes after the engine has been stopped.
These parts are very hot and will cause severe
burns.
When putting down the portable fire pump on the ground. Put it
gently and horizontally.
1
22
33
44
55
66
77
88
9
10
1111
13
14
15
16
17
18
10
1212
13
14
15
16
17
18
1
9
10
13
14
15
16
5
DESCRIPTION OF DEVICES
Suction port
The diameter of the thread for fire pump is
V20E, V20ES : BSP thread 2-1/2” (male)
V20D2, V20D2S : JIS-B-9912
dimensions of screwed type coupling
for fire hose 2-1/2”
When the pump runs while the strainer is not
installed, if you insert your finger into the
suction port, you may be seriously injured by
the rotating inducer.
Installed the standard strainer to the
suction port.
Do not run the pump if the strainer is not
installed.
If the pump is run when the strainer is not
installed, gravel may enter the pump, resulting
in significantly reduced water discharge
capacity.
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
17
18
11
1
9
10
13
14
15
16
5
DESCRIPTION OF DEVICES
Carrying handle
The fire pump is equipped with for carr ying handles
To prevent injuries, two persons
should work together when carrying
and placing the pump.
Discharge port
The diameter of the thread for fire pump is
BSP thread 2-1/2” (male) for V20E(S) model.
JIS-B-9912 dimensions of screwed type coupling for fire
hose 2-1/2”(φ82.5,5 threads per inch, thread angle 55°)
for V20D2(S) model.
Discharge valve
Use the discharge valve handle for opening and closing
the discharge valve.
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
17
18
12
1
9
10
13
14
15
16
17
18
5
DESCRIPTION OF DEVICES
Drain valve
Use the drain valves to drain water.
Fuel tank
Refill appropriate amount of gasoline to the fuel tank.
Close the fuel tank cap all the time except refuel.
Engine oil tank (V20E(S))
Refill appropriate amount of oil to the oil tank.
Close the oil tank cap all the time except filling.
The oil tank has an oil level sensor.
The warning buzzer sounds, if the engine oil is not
enough filled.
Close all the valve(s) when operating
the fire pump. If the valve is opened,
water cannot be suctioned.
If you run the pump despite of the
warning buzzer sounds, the engine
could be damaged and/or be stuck.
If the engine oil is not enough, the warning buzzer sounds.
1
22
33
44
55
66
77
88
9
10
1111
1212
13
14
15
16
17
18
13
Loading...
+ 63 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.