Toa SV-200MA User Manual

SV-200MASURVEILLANCE BOARD
INSTALLATION MANUAL
(For qualified service technicians only)
1. GENERAL DESCRIPTION
The SV-200MA Surveillance Board consists of an SV-200M board and an SV extension board to be used in combination. Installing the SV-200MA board inside the VM-2120 or VM-2240 amplifier adds the functions in the following Features section to the existing VM amplifier's functions.
• Permits monitoring of individual speaker line or power amplifier failures for status indication. For the SV-200MA's surveillance function, refer to the descriptions about the SV-200M in the VM-2120/2240 instruction manual.
• Enables the VM amplifier to bypass external attenuators on individual zone calls. Individual zone calls on the current VM amplifier do not bypass external attenuators. However, the SV extension board enables the VM amplifier to bypass external attenuators when an individual zone broadcast is made in a 4-wire attenuator system. Either enabling or disabling this function depends on the jumper setting of JP1 on the SV extension board. For setting, refer to Step 2 in the following Installation section.
• Backup amplifier function The SV extension board has a relay for BGM/paging operation with backup amplifier function, which is introduced in Sections 4-5-9 and 4-5-10 of the VM COOK BOOK as a customized relay circuit. So, the additional amplifier normally works as a BGM/paging amplifier and also acts as a backup amplifier when the internal power amplifier fails. Connections between the SV-200MA and the VM amplifier differ depending on whether this function is used or not. For details, refer to Step 6 in the following Installation section.
• Control inputs and outputs corresponding to individual zone selection status Although current VM amplifiers have expandable zone handling capability, the arrangement of speaker lines is fixed (i.e. 5 zones with 120 W or 240 W). The SV extension board permits flexible designs on speaker lines because it outputs control signals corresponding to individual zone selection status. The SV extension board also has control inputs to allow zone selections from external equipment, for Emergency messages, for example.
[Additional pin functions of the Surveillance I/O connector]
*1The VM amplifier whose internal power amplifier has first failed outputs the signal so that the BGM/paging amplifier
changes its current operation to back up the failed amplifier.
*
2
The external equipment can access this pin only when the corresponding OUTPUT status is High (24 V).
*
3
Input: No-voltage make contact input, open voltage: 24 V DC, short-circuit current: under 60 mA Output: Open collector output, withstand voltage: 24 V DC (used with VM 24 V DC output), control current: under 20 mA
Pin No. Signal Name IN/OUT Logic/Signal *
15
16 ZONE 5
17 ZONE 4
18 ZONE 3 High (24 V) Zone 3 is activated.
19 ZONE 2
20 ZONE 1
21 RY_INTATT
22 RY_EXTAMP
PA FAULT LINK
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
INPUT
OUTPUT
Open No amplifier in the system has failed. Short
Low (0 V)
Short
High (24 V) Zone 5 is activated.
Low (0 V) Zone 5 is not activated.
Short Selection of Zone 4 is canceled by external equipment.*
High (24 V) Zone 4 is activated.
Low (0 V) Zone 4 is not activated.
Short Selection of Zone 3 is canceled by external equipment.*
Low (0 V) Zone 3 is not activated.
Short
High (24 V) Zone 2 is activated.
Low (0 V) Zone 2 is not activated.
Short
High (24 V) Zone 1 is activated.
Low (0 V) Zone 1 is not activated.
Short
High (24 V) The internal Zone Attenuators are bypassed.
Low (0 V) The internal Zone Attenuators are not bypassed.
Short
High (24 V) External SP Input is active.
Low (0 V) External SP Input is not active.
3
Another amplifier in the system has failed. The internal Amplifier has failed.* Selection of Zone 5 is canceled by external equipment.*
Selection of Zone 2 is canceled by external equipment.*
Selection of Zone 1 is canceled by external equipment.*
Internal Zone Attenuator Bypass is canceled by external equipment.*
Activated external SP Input is canceled by external equipment.*
Function/Status
1
2
2
2
2
2
2
2
3. INSTALLATION
Step 1. Set the DIP switch on the SV-200M board referring to the installation manual for the VM-2120 and
VM-2240.
Step 3. Remove 4 screws on the amplifier rear panel and a
total of 6 screws on the sides to remove the cover.
Step 4. Detach the surveillance I/O blank panel on the
amplifier rear panel by removing 2 fixing snap rivets.
Step 2. JP1 on the SV extension board is a 3-pin jumper
header and its short circuit socket is normally set to A position. If you need to bypass the external attenuator not only on all-zone broadcast but also individual zone broadcast, set the socket to B position.
Note
External attenuator bypass function with individual zone broadcast can be used only with 4-wire attenuators. This function basically cannot be used with BGM/Paging function.
Step 5. Make connections of the supplied flat cables.
5-1 Remove the flat cable connected between the VM
CPU board's CN7 and the VM relay board's CN1001 of the VM amplifier.
5-2 Connect the supplied 2 flat cables to CN7 and to
CN1001, respectively.
[Orientation of the flat cable]
Note
Pay attention to the orientation of the cable so that it's contact face touches the connector's contacts.
Rear: M3 x 6 machine screw
and M3 plain washer ..... 4 pieces
SV-200M board
SV extension board
JP1
AB
Short circuit socket
B
A
A position
(Factory-preset)
Side: M4 x 8 machine screw ..... 3 pieces each
B
A
B position
VM relay board
Flat cable
Contact face
Contact
On-board connector
Surveillance I/O blank panel
Snap rivet
5
-1
Remove
CN1001
For VM relay board
CN7
CN6
5
-2
VM CPU board
Rear panel
Contact face
For VM CPU board