The RS-480VSET consists of an intercom substation RS-480V, and a video substation interface unit IF-480V. The RS-480V is an intercom substation with a color camera which is designed for indoor and outdoor use in combination with the IF-480V, and the N-8400RS substation interface unit. It requires only one CAT5 cable to connect between the RS-480V and the IF-480V.
2. SPECIFICATIONS
2.1. Basic Specifications
[RS-480V]
Power Source Supplied from IF-480V Call Button Momentary (Emergency call: Press twice within 400 ms.) Rated Input 1 W Control Output Open collector, Maximum controlled voltage: 30 V DC, Control current: 30 mA Internal Speaker Cone-type Internal Mic Electret condenser type Camera Resolution 520TVL Camera Angle 170° horizontal Minimum Illumination 0.008 lux/f2.0 Function Day & night dual mode auto switch Indicator When called: Status indicator (red) flashing
In conversation: Status indicator (red) is lit Wiring CAT5 cable, RJ45 female connector attached Transmission Range 3,000ft (AWG24) Operating Temperature –10 to +50°C (Temperature range not to freeze the speaker and switch) Finish Panel: Stainless steel, hairline
Call button: Metal, silver Dimensions 4.72”(w) x 4.72”(h) x 1.99”(d) (120 x 120 x 50.5mm) Weight 1.30 lb (605g) Supplied Accessories No.6-32UNC x 18 ... 4, Machine screw M4 x 25 ... 4 Applicable Box 2-gang electrical box: YC-302 (option)
[IF-480V]
Power Source Supplied AC adapter must be used Indicator Power LED (green), Lock LED (blue), Color LED (orange) Connectors RJ45 (to RS-480V), Removable terminal block 4P (to N-8400RS),
BNC (Video out) x2 Finish Anodized aluminum, Black Dimensions 4.13”(w) x 1.30”(h) x 5.00”(d) (105 x 33 x 127mm) Weight 10.00 oz (285g) Supplied Accessories AC adapter Options Rack mount plate: MB-480V4 (up to four IF-480Vs are mountable in 1 unit)
*Not including connectors.
TOA Electronics, Inc.
Page 2
2.2. LED Indications
and
is received properly.
IF-480V
3. CONNECTIONS
3.1. System Components
3.2 External Relay
RS-480V
To monitor displays, video recorders, or video switchers
COLOR: Orange LED lit when the color signal strength is good
LOCK: Blue LED lit when the video signal strength is good
and is received properly.
POWER: Green LED lit when the IF-480V is power on.
When the COLOR or LOCK LED is off, the following problems are suspected:
• The cable length from the RS-480V is too long.
• The problem of the camera or the cable.
CAT5 Cable (Max. 3,000ft)
IF-480V
AC adapter (accessory)
Coaxial Cable
Twisted pair cable (2-pair)
N-8400RS
TOA Electronics, Inc.
Page 3
4. WALL MOUNTING
4.72”
1.81”
4.72”
3.29”
Mount the RS-480V to an electrical box mounted in the wall.
Notes Dimensional Diagram
• When using the PA paging function, keep the switch panel as far away from the PA paging speaker as possible to avoid feedback.
• When installing the RS-480V at outdoor or locations where it gets wet, tightly seal the panel edge s. Also, provi de a we e p ho l e at the underside of the mounting box to permit water to
drain out.
[120mm]
[46mm]
[120mm]
[83.5mm]
6. MOUNTING LOCATIONS
Do not install the RS-480V in the following environments in order to achieve the maximum performance of the camera and capture the target objects clearly:
• Locations where the camera is in direct sunlight.
• Locations where the backlight occurs against the target objects.