TOA RS-170, RS-150 Installation Guide

INSTALLATION MANUAL
RS-150, RS-160, RS-170, RS-180SUBSTATION
Thank you for purchasing TOA's Substation. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
Note: For operation of the units, refer to the N-8000 series operating instructions.
1. GENERAL DESCRIPTION
TOA's RS-150, RS-160, RS-170, and RS-180 are Substations designed to be used with TOA's N-8000 Series Packet Intercom System.
2. SPECIFICATIONS
Model No. RS-150 RS-160 RS-170 RS-180 Rated Input 1 W Rated Impedance 625 Ω (1 W, 25 V) Internal Speaker 4 cm dynamic type Transmission Range 0.5 km/ø0.5 mm (AWG24)
0.8 km/ø0.65 mm (AWG22)
1.3 km/ø0.9 mm (AWG19)
Control Output (RS-180 only)
Open collector, Control current: 30 mA
(The open collector output is kept turned on till the conversation is finished after the call button was pressed.)
Operating Temperature
(Temperature range not to freeze the speaker and switch)
Finish (Panel) Stainless steel, hairline
(Call button) Resin Metal
(Printed circuit board) (RS-170, RS-180 only) Weather-resistant coating
Dimensions (w) 120 mm
(h) 120 mm (d) 48.5 mm 57.5 mm 58.5 mm
Weight 410 g 540 g 570 g Accessories Machine screw M4 x 25 ... 4, UNC No. 6-32 x 18 ... 4
Applicable Box (For ush-mount) 2-gang electrical box: YC-302 (option)
(For surface-mount) Wall-mount box: YC-822 (option) Wall-mount box: YC-822/YC-823 (option)
Note: The design and specifications are subject to change without notice for improvement.
Withstand voltage:
–10 to +50°C
30 V DC,
[Connection to the N-8000RS or N-8010RS (for 25 V line)]
(N-8000RS or N-8010RS)
A B C
Orange
Brown
Black
[Connection to the external relay (RS-180 only)]
RS-180
Blue (HOT)
White (COM)
Diode
Relay
-
Open collector output: 24 V DC (max.), 30 mA
RS-150/160/170/180
Speaker Call button
+
Status indicator (RS-180 only)
Open collector output (RS-180 only)
External power supply
24 V DC
GND
Blue (HOT)
White (COM)
Note
Cut out the control cables if they are not used to avoid short-circuiting.
4. MOUNTING
This figure is
[Flush mounting using an electrical box] [Wall surface mounting using the Wall-mount box]
Mount the substation to an electrical box mounted to the wall. Attach the Substation to the YC-822 (Indoor wall-mount
box) or YC-823 (Outdoor wall-mount box)
2-gang electrical box YC-302 (option)
Wall surface
wall.
Note
This figure is
Wall surface
RS-160/170.
RS-150/160/170/180
Note
This figure is RS-160/170.
RS-150/160/170/180
Machine screw M4 x 25 (accessory)
Wall
[Section view]
RS-150/160/170/180
Machine screw M4 x 25 (accessory)
Note
When using the PA paging function, keep the station as far away from the PA paging speaker as possible to avoid acoustic feedback.
Note
In the case of the YC-823, install it facing the ø6 mm weep hole side down.
installed on a
YC-822/823
Note
the YC-822.
YC-823 bottom
ø6 mm weep hole
[Dimensional diagram]
120
83.5
46
120
37
18.2
*1
3
[YC-822 dimensional diagram]
60
30
φ28 (Knockout hole)
4-M4 (for substation mounting)
46
83.5
66.7
84
124
Unit: mm
*1
*2
2 (RS-150)
*2
43.5 (RS-150)
φ28 hole
73
124
52.5
8-5×7 oval hole (for wall mounting)
83
Accessory screws
The RS-150, RS-160, RS-170, and RS-180 come with 2 types of screws: M4 x 25 and UNC No. 6-32 x 18. For the electrical box provided with unified threads, use the UNC No. 6-32 x 18 screw.
[YC-823 dimensional diagram]
8-5×7 oval hole (for wall mounting)
4-M4 (for substation mounting)
46
73
φ28 hole
124
83
83.5
66.7
84
124
Unit: mm
Unit: mm
φ6 weep hole
10
10
61
62
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Traceability Information for Europe
Manufacturer:
TOA Corporation 7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH Suederstrasse 282, 20537 Hamburg, Germany
URL: http://www.toa.jp/
133-06-00030-00
Loading...