Specifications
TOA Architectural and Engineering Specifications
1 Introduction
Welcome to the TOA N-8000 Network Intercom Architectural and Engineering Specification
Guide!
This document is designed to help you easily specify the groundbreaking N-8000 Network
Intercom System for your projects. If you need more information, please visit TOA on the web at
http://www.toaelectronics.com
and more!
If you’d like a demonstration or a sample for evaluation, please contact a TOA Sales
Representative at http://www.toaelectronics.com/reps.asp.
Please let me know if you have any comments on improving this guide or any suggestions for
existing or new products.
Thank you for your support!
Steve Mate, CT
Director of Marketing
TOA Electronics, Inc.
1-800-733-7088, ext. 255
steve_mate@toaelectronics.com
Acknowledgements:
Thanks to David Menasco of the TOA Product Support Group for his work in producing the
content for this guide.
where you’ll find specification sheets, manuals, CAD files, software
2
TOA Architectural and Engineering Specifications
2 Table of Contents
1 Introduction 2
2 Table of Contents 3
3 General 5
Conditions and Requirements 5
Manufacturer 5
Contractor 5
Qualifications 5
Standard Products 5
Service Facilities 5
4 System Features 5
General 5
System Programming 6
Dialing 6
Station Numbering and Naming 6
Standard Features (No Programming Required) 6
Automatic Line Release 6
Camp on Busy 6
Push to Talk and Release to Listen 6
Mic-Off 6
Remote Response 6
Single Digit Dialing 6
Redial 6
Recall 6
Ambient Noise Control 7
Selectable Features (Enabled Through Programming) 7
Paging and Response 7
PA (External) Paging and Response 7
Automatic Access to Paging 7
Call Forwarding 7
Call Transfer 7
Continuous Calling Tone - One Touch Response 7
Continuous Calling Tone - Handset Response 7
Dial Operation 7
Group Blocking (Restricted Dialing) 8
Group Remote Response 8
Master/Sub Relationship 8
Scan Monitor 8
Executive Priority 8
Programmable Station Numbers 8
Restricted Access 8
Time-Out of Conversation, Paging, or Unanswered Call 8
Optional features (Additional Equipment Required) 8
Annunciation 9
Door Control 9
BGM (Background music) 9
External audio source distribution 9
PBX Interface 9
3
TOA Architectural and Engineering Specifications
5 System Configuration and Components 10
General 10
System Size 10
Connection of External Equipment 10
Wiring 10
Service Distances 10
Exchange Components 10
N-8000EX Exchange Unit 10
N-8010EX Exchange Unit 10
E-7000TB System Terminal Blocks 11
Peripheral Interface Components 11
N-8000MI Multi-Interface Unit 11
Station Components 11
N-8500MS IP Multifunction Master Station 11
N-8540DS IP Door Station 11
N-8000MS Multifunction Master Station 12
N-8010MS Handset Master Station 12
N-8011MS Hands-Free Master Station 12
N-8020MS Industrial-Use Master Station 12
N-8031MS Flush-Mount Master Station 12
N-8050DS Door Station 13
4
TOA Architectural and Engineering Specifications
3 General
Conditions and Requirements
Manufacturer
The manufacturer shall have been in the business of manufacturing microprocessor-based
communication systems for more than ten years, and shall provide a minimum of two years
limited warranty to the authorized installing dealer.
Contractor
The contractor shall only submit products for which they are factory authorized to sell, install and
service. The contractor shall furnish all equipment, accessories and material. This shall be done
in strict accordance with specifications and applicable drawings as required for a complete and
working solid state microprocessor based intercom system. All material and /or equipment
necessary for proper operation of the system not specified or described herein shall be deemed
part of the specifications.
Qualifications
Any system substitution proposed as an equal to that herein specified shall be proven to be such
by the contractor. The contractor shall send the name and model numbers of substitute
equipment and material together with three copies of specifications and dimensional drawings to
the architect no less than ten days prior to the bid date. The contractor shall obtain the Architect's
approval in writing, by addendum, prior to bid date.
Standard Products
The equipment furnished under this specification shall be equal in every way to that
manufactured by TOA Electronics Inc. Catalog and model numbers are intended to indicate type
and quality of design and material, as well as exact operating features. All equipment shall be
designed by the manufacturer to operate as a complete system, and shall be accompanied by the
manufacturer's complete installation and operating instructions. Contractor shall provide drawings
showing all system inter-connections.
Service Facilities
The contractor shall make available to the purchaser a local service agent for the manufacturer's
equipment. This service agent shall stock the manufacturer's parts and shall provide maintenance
during normal working hours at no cost to the purchaser for the warranty period of ____ years.
Damage caused by misuse, abuse or accident is exempt from this warranty. On-site service
provided outside of normal working hours shall be made available at the prevailing overtime labor
rate.
4 System Features
General
The contractor shall furnish and install a TOA N-8000 Series Network-based Intercommunication
System. The system shall be microprocessor controlled, and the operating system (software)
shall be stored in EPROM memory. All user-programmable functions shall be stored in nonvolatile memory. The system shall offer standard, programmable and optional features. Standard
features are those available to all systems. Programmable features are those available by
changing system programming. Optional features shall be made available by installing additional
equipment.
5
TOA Architectural and Engineering Specifications
System Programming
System programming shall be accessible by the contractor, or the end user, to allow restructuring
of the system as needed. System programming shall be accessible from a Windows PC computer
on the same Ethernet network as the intercom exchange, running the dedicated setup software.
Limited programming features shall be available through a web browser running on the same IP
network as the intercom exchange.
Dialing
Dialing a station number of two to six digits in length shall establish an immediate
communications link between two stations within a system. The number of dialing digits shall be
established using the system setup software.
Station Numbering and Naming
It shall be possible to assign or change station numbers and alphanumeric names via the setup
software. A simple programming sequence shall be used without the need to open, disable or
disassemble the system hardware.
Standard Features (No Programming Required)
Automatic Line Release
The system shall release the speech path if dialing is not completed within five seconds.
Camp on Busy
A calling party shall be able to wait or “camp-on” if the called station is busy. Once the called
party becomes available, the camped-on party shall be automatically connected.
Push to Talk and Release to Listen
One way conversation shall be available by using the PUSH-TO-TALK key. Releasing the PUSHTO-TALK key shall reverse the one way conversation. The PUSH-TO-TALK key shall have
precedence over the voice switched mode.
Mic-Off
A Master Station’s microphone shall be mutable during conversation. This function shall hold a
call in progress without interruption and without forcing the user to re-establish the call.
Remote Response
A Master Station shall be able to seize a call placed to another station by entering a remote
response code.
Single Digit Dialing
A Master Station shall have the ability to dial up to 20 digits by the touch of one button. The user
shall be able to program these digits at each Master Station.
Redial
A Master Station shall be able to redial the last station called by pressing the Redial key.
Recall
A Master Station shall be able to redial the last conversation partner by pressing a designated
key.
6
TOA Architectural and Engineering Specifications
Ambient Noise Control
A Master Station shall be able to automatically adjust its voice switching threshold to compensate
for ambient noise when a designated key is pressed.
Selectable Features (Enabled Through Programming)
Paging and Response
The system programming shall allow stations to be grouped into paging zones. Paging access
shall be able to be restricted to Master Stations specified in programming. The paged party shall
be able to respond to the paging party by dialing a paging response code at the nearest Master
Station included in the paged zone.
PA (External) Paging and Response
Paging shall be available to external amplifiers for use with external PA system speakers, and
may be responded to by dialing a paging response code at a Master Station in the paged zone.
Automatic Access to Paging
Master Stations programmed for this feature shall be able to initiate a Paging Call by pressing a
designated single-digit dialing key.
Call Forwarding
Calls to a Master Station shall automatically forward to another Master Station when call forward
is activated.
No Answer Call Forwarding
When No Answer Call Forwarding is enabled for a station, calls to that station shall automatically
forward to another station if not answered within a designated number of seconds.
Busy Call Forwarding
When Busy Call Forwarding is enabled for a station, calls to that station shall automatically
forward to another station if the called station is busy when the call is placed.
Time-Based Call Forwarding
When Time-Based Call Forwarding is enabled for a station, calls to that station shall automatically
forward to another station during a designated time period.
Call Transfer
The system shall support call transfer, allowing a user to transfer a call from any Master Station to
any other station.
Continuous Calling Tone - One Touch Response
A Master Station, programmed for continuous calling tone, shall be able to answer a call by
touching any numeric key.
Continuous Calling Tone - Handset Response
A Master Station, programmed for continuous calling tone, shall be able to answer a call by lifting
the handset. Handset conversations shall be full duplex.
Dial Operation
The following selections can be made to determine dialing sequences for station dialing and
paging response.
7
TOA Architectural and Engineering Specifications
•Station dialing numbers shall be independent of connected exchange number or
other hardware configuration. Station numbering shall be programmable as two to six
digits in length.
• Paging Zone Numbering shall be programmable as single, double or triple digit.
• Paging Response shall be accomplished by pressing the paging response key or by
pressing the paging response key plus the zone number.
Group Blocking (Restricted Dialing)
The system shall support the inclusion of stations into any of 31 groups. These groups shall be
prohibited from calling or paging each other unless specifically allowed via system programming.
Group Remote Response
The system shall support remote response groups. This feature shall enable stations so
programmed to respond to calls to any station within the same remote response group.
Master/Sub Relationship
All Sub-Stations shall be able to call a designated Master Station by one touch operation.
Scan Monitor
The system shall support scan monitor groups. Each Master Station shall be able to select any
one of up to four arbitrary groups of up to 16 preprogrammed stations per group for auditory
monitoring. Setup Software shall allow the pre-programming of member stations and scan
sequence for each scan monitor group and time interval for automatic scanning. The Master
Station shall be able to select which group to scan and shall have the ability to pause the
automatic scan sequence, manually step through the sequence forward and backward, and restart the automatic scan sequence. Pressing the PTT key during scan monitor shall activate a
speech path from the Master Station to the monitored station.
Executive Priority
When a called party is busy, the caller shall be able to interrupt the conversation. The original call
shall be terminated once the new conversation is established. This function shall be selectable on
a per station basis via the programming Master Station.
Programmable Station Numbers
Station dialing numbers shall be programmable and shall be independent of connected exchange
number or other hardware configuration. Any number having the pre-selected number of digits (2-
6), and not duplicated in the system, shall be useable.
Restricted Access
Access to All-Call Paging and Zone Paging shall be able to be restricted on a per station basis.
Time-Out of Conversation, Paging, or Unanswered Call
Time-out settings shall be available, per exchange, to optionally and independently limit the
duration of conversations, paging announcements, and unanswered calls. The available settings
shall range from 10 to 999 seconds in 10 second increments.
Optional features (Additional Equipment Required)
Choose the functions you want available, and ensure that the ‘COMPONENTS’ section
(SECTION 3) of this specification includes the equipment listed "as required".
8
TOA Architectural and Engineering Specifications
Annunciation
Dry Contact Closures
The system shall provide dry contact closures that can be controlled from the Master Stations, or
activated upon call-in by designated Master Stations or Sub-Stations, for use in driving custom
annunciator panels indicating calling party or hospital waiting status, to trigger CCTV camera callup, or other custom functions. User shall have the choice of one-shot make or latching
make/break operation when controlling the contact closures manually. Install TOA N-8000MI
Multi-Interface Unit(s) as required.
Open Collector Outputs
The system shall provide open collector outputs at designated Master Stations for use in
triggering annunciator lamps or related equipment to indicate a call incoming and in-use status.
Install N-8020MS Master Station(s) as required.
Door Control
Dry Contact Closures
The system shall provide dry contact closures that can be controlled from the Master Stations for
use in door remote control or other custom functions. User shall have the choice of one-shot
make or latching make/break operation. Duration of one-shot make closure shall be software
programmable from 1 to 9 seconds. Install TOA N-8000MI Multi-Interface Unit(s) as required.
Open Collector Outputs
The system shall provide open collector outputs at designated Door Stations for use in door
remote control or other custom functions. Duration of door trigger shall be software
programmable from 1 to 9 seconds. Install N-8050DS Door Station(s) as required.
BGM (Background music)
The system shall allow connection of up to eight BGM sources, and assigned Master Stations
shall be able to access any of these sources. Install TOA N-8000MI Multi-Interface Unit(s) as
required.
External audio source distribution
The system shall allow distribution of audio from external sources to system paging zones.
Control inputs shall allow audio distribution to be activated by applying a dry contact closure.
Install TOA N-8000MI Multi-Interface Unit(s) as required.
PBX Interface
Access to a PBX system shall be possible by dialing a programmable access code. Once access
is gained, standard DTMF dial tones shall be available from within the intercom exchange to
complete dialing and connect a full duplex conversation. Calls originating from the PBX system
shall have access to intercom stations using the same station dialing numbers used by intercom
Master Stations. Install TOA N-8000MI Multi-Interface Unit(s) as required.
9
TOA Architectural and Engineering Specifications
5 System Configuration and Components
General
System Size
The intercom Exchange Unit shall support 16 station ports and 2 paging audio outputs (N8000EX only). Connecting exchanges to a local area or wide area IP network (10BASET/100BASE-TX) shall permit the establishment of multiple-exchange systems supporting up to a
maximum of 1280 station ports and a maximum of 160 paging zones. User dialed key sequences
required for inter-exchange calling and paging shall be identical to those used for intra-exchange
calling and paging. A single system shall support up to 80 total Exchange Units and MultiInterface Units. Each 16-station exchange shall allow up to eight connected stations or paging
ports to operate simultaneously in conversation with other stations (N-8000EX only).
Connection of External Equipment
The N-8000MI Multi-Interface unit shall support up to 2 audio (BGM) input sources, up to 2 audio
output lines, up to 2 inter-system tie-lines for expansion of existing EXES-6000 and EXES-2000
intercom systems, or up to 2 PBX interface connections. The Multi-Interface Unit shall also allow
simultaneous connection of up to 2 relay contact outputs, and up to 2 no-voltage make contact
inputs. A single system shall support up to 80 total Exchange Units and Multi-Interface Units.
Wiring
Each station shall be connected to its associated exchange by means of a single, non-polarized,
twisted-pair cable. Systems requiring more than one non-polarized, twisted pair cable shall not be
acceptable.
Service Distances
The system Master Stations and Sub-Stations shall remain fully functional using the following
wire gauge and distances: 26 gauge/1,870 ft; 24 gauge/2,950 ft; 22 gauge /4,920 ft; 19
gauge/9,500 ft.
Exchange Components
N-8000EX Exchange Unit
The Exchange Unit shall store and execute the system operating instructions, perform all call
routing and power distribution functions for the connected stations and shall include an
Ethernet/IP interface for connection to a standard 10BASE-T/100BASE-TX LAN or WAN network.
The Exchange Unit shall also provide two paging audio outputs and two paging control outputs.
Connection of each station shall be via one twisted pair cable terminated with supplied miniclamp connector. Connection to the network shall be via standard CAT5 cable terminated with
RJ-45 connector. Connection of paging audio and paging control outputs shall be via standard
audio (shielded) and control (unshielded) cabling terminated with 4-pin removable terminal
blocks. Connection to AC Mains power source shall be via removable IEC type Universal Power
Cord. The Exchange Unit shall mount in a standard 19" equipment rack and occupy one vertical
rack space (1.75"). Dimensions (W, H, D) shall be 16.53” x 1.74” x 13.75”. Weight shall be 9.26
lbs.
N-8010EX Exchange Unit
The Exchange Unit shall store and execute the system operating instructions, perform all call
routing and power distribution functions for the connected stations and shall include an
Ethernet/IP interface for connection to a standard 10BASE-T/100BASE-TX LAN or WAN network.
Connection of each station shall be via one twisted pair cable terminated with supplied miniclamp connector. Connection to the network shall be via standard CAT5 cable terminated with
RJ-45 connector. Connection to AC Mains power source shall be via removable IEC type
Universal Power Cord. The Exchange Unit shall mount in a standard 19" equipment rack and
10
TOA Architectural and Engineering Specifications
occupy one vertical rack space (1.75"). Dimensions (W, H, D) shall be 16.53” x 1.74” x 13.75”.
Weight shall be 9.26 lbs.
E-7000TB System Terminal Blocks
The contractor shall use a System Terminal Board for connection of the stations to the exchange.
The System Terminal Board shall be the TOA E-7000TB.
Peripheral Interface Components
N-8000MI Multi-Interface Unit
The Multi-Interface Unit shall allow the connection of up to 2 audio (BGM) input sources, up to 2
audio output lines, up to 2 inter-system tie-lines for expansion of existing EXES-6000 and EXES2000 intercom systems, or up to 2 PBX interface connections. The Multi-Interface Unit shall also
allow connection of up to 16 relay contact outputs, and up to 16 no-voltage make contact inputs.
The intercom system shall support up to 80 Multi-Interface Units. The Multi-Interface Unit shall
mount in a standard 19" equipment rack and occupy one vertical rack space (1.75"). Dimensions
(W, H, D) shall be 16.53” x 1.74” x 9.2”. Weight shall be 6.2 lbs.
Station Components
N-8500MS IP Multifunction Master Station
The IP Multifunction Master Station shall incorporate a 10BASE-T/100BASE-TX network interface
allowing intercom operation via a local area or wide area IP network and shall support Powerover-Ethernet (PoE) technology. The IP Multifunction Master Station shall be capable of handsfree full-duplex communication with all other intercom stations through a built-in speaker and
condenser microphone and shall also have a handset for full-duplex private conversations. It
shall be capable of supporting an external microphone and headset via a 1/8 inch mini-phone
jack. The IP Multifunction Master Station shall have a 32 alphanumeric character LCD display, an
in-use LED, 26 operating keys, plus 8 dedicated keys for programmable one-touch speed dialing.
In the absence of call activity, the LCD display shall indicate the time of day and station number.
During call activity, the LCD display shall indicate the calling or called station number, calling or
called station name, and call status. This station shall be equipped with an RJ-45 Ethernet jack
for connection to the network, a second RJ-45 Ethernet jack to allow connection of a PC to the
connected network, a 2.25 inch speaker, and an external speaker output. Microphone sensitivity,
speaker volume, and calling tone volume shall be software-adjustable. Speaker volume shall also
be adjustable at the station. Power supply to the IP Multifunction Master Station shall be via
Power-over-Ethernet (PoE) -capable switching hub or external AC adaptor. The station shall be
capable of being desk or wall mounted and shall be constructed of ABS resin, with a dust proof
rubber key pad. The IP Multifunction Master Station shall be the TOA N-8000MS. The optional
120 VAC power supply shall be the TOA AD-1210P. The optional wall-mount bracket shall be the
TOA YC-280.
N-8540DS IP Door Station
The IP Door Station shall incorporate a 10BASE-T/100BASE-TX network interface allowing
intercom operation via a local area or wide area IP network and shall support Power-overEthernet (PoE) technology. The IP Door Station shall provide a call switch and an in-use LED,
and shall be capable of hands-free full-duplex communication with other stations through a builtin speaker and condenser microphone. The IP Door Station shall provide an open collector output
for use in controlling a door-opening relay or other external equipment. Power supply to the IP
Door Station shall be via Power-over-Ethernet (PoE) -capable switching hub or external AC
adaptor. The IP Door Station faceplate shall be brushed stainless steel, #11 gauge and shall
mount to a standard three-gang enclosure. Pressing and releasing the call button shall initiate
call-in to a pre-programmed Master Station or Master Station Group. Microphone sensitivity,
speaker volume, calling tone volume, and open-collector output duration shall be softwareadjustable. The IP Door Station shall be a TOA N-8540DS. The optional 120 VAC power supply
shall be the TOA AD-1210P. The optional flush-mount backbox shall be the TOA YC-150. The
optional surface-mount backbox shall be the TOA YS-13A.
11
TOA Architectural and Engineering Specifications
N-8000MS Multifunction Master Station
The Multifunction Master Station shall connect to the exchange mainframe via one unshielded
twisted pair (UTP) cable. The Multifunction Master Station shall be capable of hands-free fullduplex communication with all other intercom stations through a built-in speaker and condenser
microphone and shall also have a handset for full-duplex private conversations. It shall be
capable of supporting an external microphone and headset via a 1/8 inch mini-phone jack. The
Multifunction Master Station shall have a 32 alphanumeric character LCD display, an in-use LED,
26 operating keys, plus 8 dedicated keys for programmable one-touch speed dialing. In the
absence of call activity, the LCD display shall indicate the time of day and station number. During
call activity, the LCD display shall indicate the calling or called station number, calling or called
station name, and call status. This station shall be equipped with a modular line jack, a 2.25 inch
speaker, and an external speaker output. Microphone sensitivity, speaker volume, and calling
tone volume shall be software-adjustable. Speaker volume shall also be adjustable at the station.
The station shall be capable of being desk or wall mounted and shall be constructed of ABS
resin, with a dust proof rubber key pad. The Multifunction Master Station shall be the TOA N8000MS. The optional wall-mount bracket shall be the TOA YC-280.
N-8010MS Handset Master Station
The Handset Master Station shall connect to the exchange mainframe via one unshielded twisted
pair (UTP) cable. The Handset Master Station shall be capable of hands-free full-duplex
communication with all other intercom stations through a built-in speaker and condenser
microphone and shall also have a handset for full-duplex private conversations. The Handset
Master Station shall have an in-use LED and 20 operating keys. This station shall be equipped
with a modular line jack, a 2.25 inch speaker, and software-adjustable microphone sensitivity,
speaker volume, and calling tone volume controls. It shall be capable of being desk or wall
mounted and shall be constructed of ABS resin, with a dust proof rubber key pad. The Handset
Master Station shall be the TOA N-8010MS. The optional wall-mount bracket shall be the TOA
YC-280.
N-8011MS Hands-Free Master Station
The Hands-Free Master Station shall connect to the exchange mainframe via one unshielded
twisted pair (UTP) cable. The Hands-Free Master Station shall be capable of hands-free fullduplex communication with all other intercom stations through a built-in speaker and condenser
microphone. The Hands-Free Master Station shall be equipped with an in-use LED, 20 operating
keys, a modular line jack and a 2.25 inch speaker. Microphone sensitivity, speaker volume, and
calling tone volume shall be software-adjustable. Speaker volume shall also be adjustable at the
station. The station shall be capable of being desk or wall mounted and shall be constructed of
ABS resin, with a dust proof rubber key pad. The Hands-Free Master Station shall be the TOA N8011MS. The optional wall-mount bracket shall be the TOA YC-290.
N-8020MS Industrial-Use Master Station
The Industrial-Use Master Station shall connect to the exchange mainframe via one unshielded
twisted pair (UTP) cable. The Industrial-Use Master Station shall be surface mounted and shall
be splash and dust resistant. This station shall be capable of hands-free full-duplex
communication with all other intercom stations through a built-in speaker and condenser
microphone and shall also have a handset for full-duplex private conversations. The IndustrialUse Master Station shall be equipped with an in-use LED, 20 operating keys, a modular line jack
and a 2.25 inch speaker. Microphone sensitivity, speaker volume, and calling tone volume shall
be software-adjustable. Speaker volume shall also be adjustable at the station. The station shall
be capable of being desk or wall mounted and shall be constructed of ABS resin, with a splashproof key pad and weather-resistant seals covering all cable entry points. The Industrial-Use
Master Station shall be the TOA N-8020MS. The optional wall-mount bracket shall be the TOA
YC-280.
N-8031MS Flush-Mount Master Station
The Flush-Mount Master Station shall connect to the exchange mainframe via one unshielded
twisted pair (UTP) cable. The Flush-Mount Master Station shall mount in a standard 5-gang
12
TOA Architectural and Engineering Specifications
electrical box and shall be splash and dust resistant. This station shall be capable of hands-free
full-duplex communication with all other intercom stations through a built-in speaker and
condenser microphone. A handset option shall be available to enable private full-duplex
conversations. The Flush-Mount Master Station shall be equipped with an in-use LED, 20
operating keys, a 2.25 inch speaker, and remote control connections for keys 7, 8, 9, and C to
enable one-touch dialing of pre-assigned stations and call cancellation using a remote
momentary-contact switch. Microphone sensitivity, speaker volume, and calling tone volume shall
be software-adjustable. Speaker volume shall also be adjustable at the station. The station shall
incorporate a stainless steel front panel, with a splash-proof key pad and speaker. The FlushMount Master Station shall be the TOA N-8031MS. The optional handset shall be the TOA RS-
191. The optional flush-mount backbox shall be the TOA YC-241. The optional surface-mount
backbox shall be the TOA YC-251.
N-8050DS Door Station
The Door Station shall connect to the exchange mainframe via one unshielded twisted pair (UTP)
cable. The Door Station shall provide a call switch and an in-use LED, and shall be capable of
hands-free full-duplex communication with other stations through a built-in speaker and
condenser microphone. The Door Station shall provide an open collector output for use in
controlling a door-opening relay or other external equipment. The Door Station faceplate shall be
brushed stainless steel, #11 gauge and shall mount to a standard three-gang enclosure. Pressing
and releasing the call button shall initiate call-in to a pre-programmed Master Station or Master
Station Group. Microphone sensitivity, speaker volume, calling tone volume, and open-collector
output duration shall be software-adjustable. The Door Station shall be a TOA N-8050DS. The
optional flush-mount backbox shall be the TOA YC-150. The optional surface-mount backbox
shall be the TOA YS-13A.