Toa DA-250FH CE-AU User Manual

Page 1
MULTICHANNEL POWER AMPLIFIERS
DA-250F CE301 DA-250F CE-GB DA-250F CE-AU
DA-250F
DA-250FH
OPERATING INSTRUCTIONS
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
DA-250FH CE301 DA-250FH CE-GB DA-250FH CE-AU
Page 2
2
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS ............................................................................... 3
2. GENERAL DESCRIPTION ............................................................................. 5
3. FEATURES .......................................................................................................... 5
4. HANDLING PRECAUTIONS .......................................................................... 5
5. INSTALLATION PRECAUTIONS ................................................................. 6
6. NOMENCLATURE AND FUNCTIONS
Front ......................................................................................................................... 7
Rear .......................................................................................................................... 8
7. SETTINGS AND CONNECTIONS
7.1. Switch Settings and Speaker Connections
7.1.1. When using the DA-250F ........................................................................ 9
7.1.2. When using the DA-250FH .................................................................... 11
8. REMOVABLE TERMINAL PLUG CONNECTION .................................. 12
9. PROTECTION OPERATION LIST ............................................................... 13
10. TAMPER-PROOF CAP ATTACHMENT .................................................... 13
11. CLEANING THE FILTER ................................................................................ 14
12. DIMENSIONAL DIAGRAM ............................................................................ 15
13. BLOCK DIAGRAMS
13.1. DA-250F ........................................................................................................... 16
13.2. DA-250FH ........................................................................................................ 17
14. SPECIFICATIONS
14.1. DA-250F CE301, DA-250F CE-GB, DA-250F CE-AU ..................................... 18
14.2. DA-250FH CE301, DA-250FH CE-GB, DA-250FH CE-AU ............................. 19
Page 3
3
When Installing the Unit
• Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.
• Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock.
• Be sure to replace the unit's terminal cover after connection completion. Because the voltage of up to 100 V is applied to the high impedance speaker terminals, never touch these terminals to avoid electric shock. (DA-250FH only)
• External wiring connected to the terminals marked with requires installation by an instructed person.
(DA-250FH only)
• The apparatus shall be connected to a mains socket outlet with a protective earthing connection.
When the Unit is in Use
• Should the following irregularity be found during use, immediately turn off this unit's power switch, disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock.
· If you detect smoke or a strange smell coming from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If the power supply cord is damaged (exposure of the core, disconnection, etc.)
· If it is malfunctioning (no tone sounds.)
• To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing such as modification inside the unit to qualified service personnel.
• Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock.
• Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.
• Do not touch a plug during thunder and lightning, as this may result in electric shock.
When Installing the Unit
• Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.
• When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.
1. SAFETY PRECAUTIONS
• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or cautions regarding safety.
• After reading, keep this manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
WARNING
CAUTION
CAUTION
Page 4
4
• When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.
• Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.
• To avoid electric shocks, be sure to first turn off this unit's power switch when connecting speakers.
• The unit is designed exclusively to be mounted in an equipment rack. Be sure to follow the instructions below when rack-mounting the unit. Failure to do so may cause a fire or personal injury.
· Install the equipment rack on a stable, hard floor.
Fix it with anchor bolts or take other arrangements to prevent it from falling down.
· The supplied rack-mounting screws can be used
for the TOA equipment rack only. Do not use them for other racks.
· When installing the unit in a rack other than that
of TOA, be sure to use the screws with a diameter of over 5 mm and length of over 12 mm to mount the unit.
· When connecting the unit's power cord to an AC
outlet, use the AC outlet with current capacity allowable to the unit.
When the Unit is in Use
• Make sure to set all input level controls to ∞(infinity) position before power is switched on. Loud noise produced when power is switched on with any of those controls set to the position other than ∞position can impair hearing.
• Do not operate the unit for an extended period of time with the sound distorting. Doing so may cause the connected speakers to heat, resulting in a fire.
• Contact your TOA dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result.
• If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely.
• Turn off this unit's power switch, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.
The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Page 5
5
2. GENERAL DESCRIPTION
TOA's DA-250F and DA-250FH Multichannel Power Amplifiers feature high power handling capabilities and durability. The DA-250F is configured with 250 W x 4 channels (4 Ω output) and 170 W x 4 channels (8 Ω output), and the DA-250FH features a 250 W x 4 channels (100 V line, 40 Ω output) configuration. Besides, the DA-250F's output is made available for bridge connection, allowing it to be used as a 500 W (8 Ω) x 2 channels stereo amplifier or as a 3-channel amplifier comprised of 500 W (8 Ω) + 250 W (4 Ω) x 2 channels. Their wide range of applications include stores and permanent sound systems.
3. FEATURES
• 1U rack mounting size*.
• Low power consumption and light weight.
• An input signal to Channel 1 can be routed to all channels, and the output level adjusted using the input level control for each channel.
• Electronically-balanced inputs.
• Input terminals employ removable terminal blocks to provide maximum connection ease.
• Equipped with the LED indicators that show the input/output status, etc.
• Built-in protection circuitry disconnects the power amplifier's output from the load when a short circuit, overload, or unusual temperature rise occurs.
* 1U size = 44.5 mm (reference size)
4. HANDLING PRECAUTIONS
• Keep the input cable away from the output cable. If installed close to each other, oscillation could occur.
• To avoid unit failures, never connect outputs of two or more channels in parallel.
• Only connect speakers with an impedance equal to or greater than those specified. Connecting speakers with a smaller impedance than specified could cause damage to the unit.
• Periodically clean the filter located inside the ventilation panel on the unit's front panel. If the filter becomes clogged, heat will become trapped inside the enclosure.
• Install the unit in locations where the temperature is between –10 and +40°C and the moisture is less than 90%RH (no dew condensation must be formed).
• To clean, be sure to first turn off this unit's power switch, then wipe with a dry cloth. When the unit gets very dirty, use a cloth damped in a neutral cleanser. Never use benzene, thinner, alcohol, or chemically-treated cleaning cloth because such volatile liquids could deform or discolor the unit.
• The fan is a consumable product. As a guideline, we recommend that it be replaced with a new one when its total operating time reaches approximately 20000 hours (when used in ambient temperatures of approximately 25°C).
Note: The above figure is simply a guideline, and does not guarantee the fan’s operating life. Since
broadcasts from the digital power amplifier could be disabled if the fan malfunctions, the fan requires regular inspection and maintenance. For maintenance service, please contact the dealer from whom the digital amplifier was purchased.
Page 6
6
5. INSTALLATION PRECAUTIONS
• The supplied power supply cord is designed for exclusive use with this unit. Never use it with other equipment.
• When mounting the unit in an equipment rack, the inside of the rack must be sufficiently ventilated. To achieve sufficient ventilation, remove all panels on the rear of the rack.
• When mounting the unit in the rack, also mount a Perforated Panel larger than 1U in size*:
(1) at the top and the bottom of the rack, and (2) above and below every 5 units.
• Robust structure is one of the unit's main features. However, if the strength is particularly needed when installing the unit in the rack, use a supporting runner for the safety purposes.
* 1U size = 44.5 mm (reference size)
The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks. When installing the unit in a rack other than that of TOA, be sure to use the screws with a diameter of over 5 mm and length of over 12 mm to mount the unit. Failure to do so may cause personal injury.
CAUTION
Power amplifiers
(5 units)
Power amplifiers
(5 units)
Perforated panel
Page 7
7
1. Power switch [ ON / OFF]
Turning this switch on causes the amplifier to function, and turning it off causes the amplifier to cease function.
Note: The unit is not completely disconnected
from the power supply even if this Power switch is turned off.
2. Power indicator [POWER]
Lights blue when the Power switch (1) is turned on.
3. Input level controls
[CH 1 (BRIDGE 1), CH 2, CH 3 (BRIDGE 2), CH 4]
Adjust the input level of each channel. Turn the control clockwise to increase the input level and counterclockwise to decrease the level.
4. Ventilation panel (Air Vent)
A filter is located inside the ventilation panel. To clean the filter, remove the ventilation panel. (See p. 14; Cleaning the Filter.)
5. Indicators [INPUT, OUTPUT, PEAK, PROTECT]
The indicators are as follows from left to right:
• Input indicator [INPUT]
Lights green regardless of the input level control setting when an input signal level exceeds about –20 dB.
• Output indicator [OUTPUT]
Lights yellow when an output level exceeds about 1W at an 8 Ω load (DA-250F) or 40 Ω load (DA-250FH).
• Peak indicator [PEAK]
Lights red when an output signal clips (distortion occurs).
Note
When the Peak indicator lights, turn the input level control (3) counterclockwise until its light extinguishes or decrease the input signal level of the connected external device. Operating the unit while the Peak indicator remains lit may cause the protection circuitry to be activated.
• Protection indicator [PROTECT]
Lights red when the protection circuitry is activated. (See p. 13; Protection Operation List.) When the power is switched on, this indicator lights for about 2 seconds and then extinguishes.
When a bridge connection is made (DA-250F only)
• When Channels 1 and 2 are bridge­connected (BRIDGE 1 ON/OFF switch (9) is set to ON), the CH 1/BRIDGE 1 level control adjusts the input levels of Channels 1 and 2. In this event, the CH 2 level control cannot be used.
• When Channels 3 and 4 are bridge­connected (BRIDGE 2 ON/OFF switch (9) is set to ON), the CH 3/BRIDGE 2 level control adjusts the input levels of Channels 3 and 4. In this event, the CH 4 level control cannot be used.
6. NOMENCLATURE AND FUNCTIONS
[Front]
DA-250F
DA-250FH
1243 5
1243 5
Page 8
8
[Rear]
6. AC inlet
Connect the supplied power cord to this inlet. The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible.
7. Functional ground terminal [SIGNAL GND]
Hum noise may be generated when external equipment is connected to the unit. Connecting this terminal to the functional ground terminal of the external equipment may reduce the hum noise.
Note
This terminal is not for protective earth.
8.
Speaker output terminals (with a terminal cover) [OUTPUTS (DA-250F), OUTPUTS 100 V (DA-250FH)]
Connect speaker cables to these terminals.
9. BRIDGE ON/OFF switches (DA-250F only) [BRIDGE 1, BRIDGE 2, ON / OFF]
Used when bridge-connecting the unit's Channels 1 and 2, and Channels 3 and 4. (See p. 9; Settings and Connections.)
• 4-channel output mode
Set both BRIDGE 1 and 2 switches to OFF. (factory-preset)
• 3-channel output mode
Set either BRIDGE 1 or 2 switches to ON. When bridge-connecting Channels 1 and 2, set BRIDGE 1 switches to ON, and BRIDGE 2 switches to ON when bridge-connecting Channels 3 and 4.
• 2-channel output mode
Set both BRIDGE 1 and 2 switches to ON.
Note
Be sure to first turn off the Power switch (1) when changing these switch settings.
10. CH 1 mode ON/OFF switch [CH 1 TO ALL, ON / OFF]
Setting this switch to ON transmits the Channel 1 input signal to all channels. (CH1 to All ch mode) Note that output signal levels can be individually adjusted with each channel's Input level control (3). Setting this switch to OFF (factory-preset) transmits each channel's input signal to each corresponding channel. (Each ch mode)
Note
Be sure to first turn off the Power switch (1) when changing this switch setting.
11. Input terminals [INPUTS]
Electronically-balanced inputs of 3-pin removable terminal block type. (H: Hot, C: Cold, E: Earth)
6 7
DA-250F
6 7 10
DA-250FH
8
9 910
11
8
11
Page 9
9
Step 1. Turn off this unit's Power switch.
Step 2. Set the BRIDGE ON/OFF switches (DA-250F only) and CH 1 mode ON/OFF switch.
Step 3. Connect the sound source equipment to the Input terminals.
Note: Refer to p. 12 for the removable terminal plug connection.
Step 4. Connect speakers to the Speaker output terminals.
4-1. Unscrew the output terminal cover.
4-2. Strip 10 mm of insulative jacket from the end of the speaker cable,
as shown in the figure at right.
4-3. Connect speaker cables to the output terminals.
4-4. Replace the output terminal cover in place.
Be sure to replace the unit's terminal cover after connection completion. Because high voltage is generated at the speaker output terminals, never touch these terminals to avoid electric shock. (DA-250FH only)
WARNING
7.1.1. When using the DA-250F
7. SETTINGS AND CONNECTIONS
7.1. Switch Settings and Speaker Connections
CH 1 mode ON/OFF switch
[Rear panel]
Speaker output terminals
(with a terminal cover)
BRIDGE 2 ON/OFF switch
(DA-250F only)
Input terminals
Note: The figure shows the DA-250F.
BRIDGE 1 ON/OFF switch (DA-250F only)
[4 inputs - 4 outputs] (factory-preset)
CH4
-
+
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Setting
OFF
OFF
OFF
CH3
-
10 mm
CH2
+
CH1
-
+
-
+
Speaker output terminals
+
4 – 8 Ω
– +
4 – 8 Ω
– +
4 – 8 Ω
– +
4 – 8 Ω
Page 10
10
[1 input - 4 outputs]
CH1
CH1
CH2
CH3
CH4
[2 inputs - 2 outputs]
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Setting
OFF
OFF
ON
CH4
-
CH3
CH2
+
-
+
CH1
-
+
-
+
Speaker output terminals
+
4 – 8 Ω
+
4 – 8 Ω
+
4 – 8 Ω
+
4 – 8 Ω
CH1
CH1
CH2
CH3
CH3
CH4
[1 input - 2 outputs]
CH1
CH1
CH2
CH3
CH4
[3 inputs - 3 outputs (1)]
CH1
CH1
CH2
CH2
CH3
CH3
CH4
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Setting
ON
ON
OFF
Setting
ON
ON
ON
Setting
OFF
ON
OFF
BRIDGE 2
Speaker output terminals
-
-
+
+
BRIDGE 1BRIDGE 2
+
8 Ω
+
8 Ω
Speaker output terminals
-
-
+
+
BRIDGE 1BRIDGE 2
+
8 Ω
– +
8 Ω
CH1
CH2
-
-
+
+
Speaker output terminals
-
+
+
4 – 8 Ω
– +
4 – 8 Ω
– +
8 Ω
[3 inputs - 3 outputs (2)]
CH1
CH1
CH2
CH3
CH3
CH4
CH4
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Setting
ON
OFF
OFF
CH4
-
CH3
-
+
+
Speaker output terminals
-
+
BRIDGE 1
+
8 Ω
– +
4 – 8 Ω
– +
4 – 8 Ω
Page 11
11
[1 input - 3 outputs (1)]
7.1.2. When using the DA-250FH
CH1
CH1
CH2
CH3
CH4
[1 input - 3 outputs (2)]
CH1
CH1
CH2
CH3
CH4
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
Setting
OFF
ON
ON
Setting
ON
OFF
ON
BRIDGE 2
CH4
-
CH1
CH2
-
-
+
+
Speaker output terminals
-
+
+
4 – 8 Ω
+
4 – 8 Ω
+
8 Ω
CH3
-
+
+
Speaker output terminals
-
+
BRIDGE 1
+
8 Ω
– +
4 – 8 Ω
– +
4 – 8 Ω
[4 inputs - 4 outputs] (factory-preset)
CH1
CH1
CH2
CH2
CH3
CH3
CH4
CH4
[1 input - 4 outputs]
CH1
CH1
CH2
CH3
CH4
Switch Setting
CH 1 mode OFF
Switch Setting
CH 1 mode ON
CH4
-
CH4
-
CH3
CH2
+
-
+
CH1
-
+
-
+
Speaker output terminals
+
40 Ω
– +
40 Ω
– +
40 Ω – +
40 Ω –
CH3
CH2
+
-
+
CH1
-
+
-
+
Speaker output terminals
+
40 Ω
– +
40 Ω
– +
40 Ω
– +
40 Ω
Page 12
12
Connector connections
Step 1. Loosen the terminal screw, then insert the cable.
Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.)
Tip
Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm in width
8. REMOVABLE TERMINAL PLUG CONNECTION
Cautions
• Be sure to use shielded cables for audio signal lines.
• Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.
• Use cables of AWG 12 – 24.
Cable end treatment
Shielded cable
7 mm
20 mm
Slotted screwdriver
Tightens Loosens
2
1
Hot
Earth
Cold
Shielded cable
Bit shape 3 mm
1
Terminal screw
Removable terminal plug
Page 13
13
10. TAMPER-PROOF CAP ATTACHMENT
To protect the input level control from accidental operation, it is recommended to replace the control knob with the supplied tamper-proof cap as illustrated.
9. PROTECTION OPERATION LIST
Failure Protection Operation Indicator Remedy Recovery
Overcurrent due to overload
Short circuit Current limiter activated.
Temperature rise at power amp. heat sink (over 110°C)
Temperature rise inside the unit (over 80°C)
Abnormal DC voltage output
Current limiter activated when impedance drops below the specified value.
Load is disconnected.
Load disconnected. Protection indicator
Built-in amplifier unit that caused the failure halted.
Load disconnected. Protection indicator
Peak indicator lights. Remove overload. Connecting a correct load
automatically restores normal operation.
Protection indicator lights.
lights.
Four indicators of the corresponding channel extinguish.
lights.
Check speakers and lines for short circuit.
Check the unit for correct ventilation and overload.
Contact the TOA dealer where the unit was purchased.
Turn off this unit's Power switch. Correct the load, then turn on the power.
Operation automatically returns to normal when the temperature decreases.
Input level control
Tamper-proof cap (accessory)
Page 14
14
11. CLEANING THE FILTER
Step 1. Turn off this unit's Power switch.
Step 2. Remove the ventilation panel as shown in the figure.
Step 3. Detach the filter inside the ventilation panel.
Step 4. Clear the filter of dust.
Step 5. Replace the filter and ventilation panel.
Ventilation Panel
Filter
3
2
Detach the panel by pressing on the left or right sides.
Ventilation Panel
Page 15
15
12. DIMENSIONAL DIAGRAM
Unit: mm
442
371 22.5
401.8
465
482
31.8
44
Page 16
16
13. BLOCK DIAGRAMS
13.1. DA-250F
BRIDGE 1
OUTPUT
+
CH 1
OUTPUT
-
BRIDGE 2
OUTPUT
-
+
CH 2
OUTPUT
CH 3
OUTPUT
+
-
-
+
CH 4
OUTPUT
OUTPUT 1
relay
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
OUTPUT 2
relay
ON
10 dB)
-
relay
OUTPUT 3
Short Detector
Current Limiter
Protection Circuit
OFF
BRIDGE 1 ON/OFF switch
10 dB
+4 dB
-
10 dB)
-
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
OUTPUT 4
relay
ON
10 dB)
-
Short Detector
Current Limiter
Protection Circuit
OFF
BRIDGE 2 ON/OFF switch
10 dB
+4 dB
-
10 dB)
-
CH 1 INPUT
E
H
C
CH 1 sensitivity
selection jumper
CH 1
input level
control
CH 2 INPUT
(+4 dB/
H
C
CH 2 sensitivity
selection jumper
(+4 dB/
CH 2
input level
control
E
CH 3 INPUT
E
H
C
CH 3 sensitivity
selection jumper
CH 3
input level
control
(+4 dB/
CH 4 INPUT
E
H
C
CH 1 TO ALL
CH 4
switch
input level
CH 4 sensitivity
selection jumper
(+4 dB/
control
Page 17
17
13.2. DA-250FH
CH 1
+
-
OUTPUT
CH 2
OUTPUT
+
-
CH 3
OUTPUT
+
-
CH 4
OUTPUT
+
-
OUTPUT 1
relay
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
relay
OUTPUT 2
10 dB)
-
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
OUTPUT 3
relay
10 dB)
-
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
OUTPUT 4
10 dB)
-
relay
Short Detector
Current Limiter
Protection Circuit
10 dB
+4 dB
-
10 dB)
-
CH 1 INPUT
E
H
C
CH 1 sensitivity
selection jumper
CH 1
input level
control
CH 2 INPUT
(+4 dB/
H
C
CH 2 sensitivity
selection jumper
(+4 dB/
CH 2
input level
control
E
CH 3 INPUT
E
H
C
CH 3 sensitivity
selection jumper
CH 3
input level
control
(+4 dB/
CH 4 INPUT
E
H
C
CH 1 TO ALL
CH 4
switch
input level
control
CH 4 sensitivity
selection jumper
(+4 dB/
Page 18
18
220 – 240 V AC, 50/60 Hz
Class D
200 W (based on EN standards)
1200 W (rated output 4 Ω x 4)
800 W (rated output 8 Ω x 4)
4 circuits, +4 dB* (1.23 V, input level control in maximum position), 10 kΩ, electronically-balanced, removable terminal block (3 pins) CH 1 mode ON/OFF switch (ON: CH 1 to All ch, OFF: Each ch)
4 channels: 250 W x 4 (4 Ω), 170 W x 4 (8 Ω) 2 channels (BRIDGE): 500 W x 2 (8 Ω) M4 screw terminal, distance between barriers: 8.8 mm
20 – 20,000 Hz (±1 dB)
0.1% (1 kHz), 0.3% (20 – 20,000 Hz)
Protection against excessive current flow due to overload, short circuit, unusual DC voltage output, temperature rise at power amp. heat sink (over 110°C), temperature rise inside the unit (over 80°C)
100 dB (A-weighted)
70 dB (A-weighted)
Power (blue) x 1, Input (green) x 4, Output (yellow) x 4, Peak (red) x 4, Protect (red) x 4
Forced air cooling
–10°C to +40°C
Under 90%RH (no condensation)
Panel: Aluminum, black, alumite Case: Plated steel sheet
482. (w) x 44 (h) x 401.8 (d) mm
6.8 kg
Power Source
Amplification system
Power Consumption
Input
Rated Output
Frequency Response
Total Harmonic Distortion
Protection Circuit
S/N Ratio
Crosstalk
LED Indicator
Cooling
Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
14. SPECIFICATIONS
* 0 dB = 0.775 V
Note: The design and specifications are subject to change without notice for improvement.
Power cord (2 m) ................................................................. 1
Removable terminal plug (3 pins) ........................................ 4
Rack mounting screw (with plain washer) 5 x 12 ................ 4
Tamper-proof cap ................................................................ 4
• Accessories
14.1. DA-250F CE301, DA-250F CE-GB, DA-250F CE-AU
Page 19
19
* 0 dB = 0.775 V
Note: The design and specifications are subject to change without notice for improvement.
Power cord (2 m) ................................................................. 1
Removable terminal plug (3 pins) ........................................ 4
Rack mounting screw (with plain washer) 5 x 12 ................ 4
Tamper-proof cap ................................................................ 4
• Accessories
220 – 240 V AC, 50/60 Hz
Class D
200 W (based on EN standards) 1150 W (rated output 100 V line, 40 Ω x 4)
4 circuits, +4 dB* (1.23 V, input level control in maximum position), 10 kΩ, electronically-balanced, removable terminal block (3 pins) CH 1 mode ON/OFF switch (ON: CH 1 to All ch, OFF: Each ch)
4 channels: 250 W x 4 (100 V line, 40 Ω) M4 screw terminal, distance between barriers: 8.8 mm
50 – 20,000 Hz (–3 dB, +1 dB)
0.1% (1 kHz), 0.3% (100 – 20,000 Hz)
Protection against excessive current flow due to overload, short circuit, unusual DC voltage output, temperature rise at power amp. heat sink (over 110°C), temperature rise inside the unit (over 80°C)
100 dB (A-weighted)
70 dB (A-weighted)
Power (blue) x 1, Input (green) x 4, Output (yellow) x 4, Peak (red) x 4, Protect (red) x 4
Forced air cooling
–10°C to +40°C
Under 90%RH (no condensation)
Panel: Aluminum, black, alumite Case: Plated steel sheet
482. (w) x 44 (h) x 401.8 (d) mm
6.8 kg
Power Source
Amplification system
Power Consumption
Input
Rated Output
Frequency Response
Total Harmonic Distortion
Protection Circuit
S/N Ratio
Crosstalk
LED Indicator
Cooling
Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
14.2. DA-250FH CE301, DA-250FH CE-GB, DA-250FH CE-AU
Page 20
133-22-238-2A
URL: http://www.toa.jp/
Traceability Information for Europe (EMC directive 2004/108/EC)
Manufacturer:
TOA Corporation 7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH Suederstrasse 282, 20537 Hamburg, Germany
Loading...