Toa CU-62, EXES-6000 Specifications

2-WIRE INTERCOM SYSTEM
EXES-6000
CU-62
CALL ALERT RELAY UNIT
Features
1. Flush or surface mountable with optional back box.
CALL ALERT RELAY UNIT (CU-62)
3. Call indicator LED.
4. Two relay output contacts.
5. Call tone duration adjustment.
General Description
The CU-62 call alert relay unit is designed for use
who otherwise fail to notice the incoming calls.
with the TOA EXES-6000 intercom systems. The relay remains activated for a maximum of 2
It is provided with 2 relay output contacts which
sense incoming calls to the station and activate such
seconds for a single incoming call tone, or
continuously for duration of the continuous external call indicators as lamps and buzzers, incoming call tone, and causes the external signalling to the people in high noise level areas
Specifications
Supply voltage: Current consumption: Controls: Rated relay contact
capacity:
Adjustments:
Finish:
Associated equipment:
Weight: Dimensions:
24V DC (22V to 28V) Max. 0.08A
Two-relay output contacts
0.5A (24V DC)
l
Relay activated duration—
Max. 2.0 sec. (full clockwise)
l
Activated sensitivity Brushed aluminum front panel DS-100 (DC power supply unit)
YC-150 (flush-mounted back box) YS-13 (surface-mounted back box)
570g (1.26 Ibs.) See the Dimensional Diagram
as below.
indicators to operate.
Architects and Engineers Specifications
The call alert relay unit shall be TOA model CU-62. The call alert relay unit shall be designed for use with
the TOA EXES-6000 series intercom systems, and shall be capable of activating external lamps, buzzers or other external call indicators by responding to the
station call tone. The call alert relay unit shall be operated on 24V DC, and shall have a rated contact capacity of 0.5A (24 DC). It shall also be equipped with a “call alert” indicator for quick monitoring of the
relay activation. The relay shall remain activated for a
maximum of 2 seconds for a single incoming call tone, or continuously for duration of the continuous
incoming call tone, and shall cause the external
indicators to operate. The call alert relay unit shall be either surface mounted or flush mounted in the wall and its panel shall be finished with brushed aluminum.
Dimensional Diagram
Block Diagram
Dimensional Diagram of Associated Equipment
YC-150
DS-100
YS-13
TOA Electronics, Inc.,
South San Francisco, California 94080
Specifications are subject to change without notice.
601 Gateway Boulevard
© 1990 TOA Electronics, Inc. Printed in U.S.A. 09-90-1