Toa CM-960 User Manual

INSTALLATION MANUAL
CEILING MOUNT SPEAKER
Please
follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
1. SAFETY PRECAUTIONS
Before installation or use, be sure to carefully read all the instructions in this section for correct and safe operation.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.
Install the unit only in a location that can structurally support the weight of the unit and the mounting bracket. Doing otherwise may result in the speaker falling down and causing personal injury and/or property damage.
CAUTION
Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
Do not operate the speaker for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire.
4. APPLICABLE SPEAKER PANELS
• CM-760: CP-73, CP-77
• CM-960: CP-93, CP-97
5. INSTALLATION
Step 1. Make a hole with the following diameter in the
[Mounting hole diameter]
• CM-760: ø150 mm ±3
• CM-960: ø200 mm ±3
Step 2. Connect the speaker cables to the push-in terminal
Step 3. Mount the speaker in the ceiling. Usable ceiling
Step 4. Connect springs to the speaker panel to attach it.
CM-760, CM-960
ceiling.
block. (Parallel-branch connections can be made.)
boards are those which are up to 50 mm thick.
Ceiling
Max. 50 mm
2. INSTALLATION PRECAUTION
Never cut off the wire ties attached to the coil spring as shown below since they serve to prevent the speaker panel from falling off if the coil spring accidentally beaks.
Speaker
Wire ties
Coil spring
3. WIRING DIAGRAM
3 W (3.3 kΩ)
6 W (1.7 kΩ)
COM
Bridging terminal
Terminal
(BRN)
(BLK)
(WHT)
6.7 kΩ
3.3 kΩ
1.7 kΩ
MT
COM
6. CONNECTIONS
Cables connectable to the push-in terminals are IV or HIV
cables (solid wire of ø0.8 – 1.2 mm or stranded-conductor
of 0.75 – 1.25 mm
Step 1. Trim a cable jacket about 9 mm. (Use the strip
gauge provided at the terminal block.)
Step 2. Fully insert the cable into the hole in the terminal
according to the cable indications on the terminal. To remove the cable, press the terminal button, then pull the cable.
Manufacturer:
TOA Corporation 7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH Suederstrasse 282, 20537 Hamburg, Germany
2
).
Traceability Information for Europe
URL: http://www.toa.jp/
533-06-083-2B