TMB Solaris Flare Q+ RZ 50, Solaris Flare Q+ Rayzr 50, Solaris Flare Q+ RZ 100, Solaris Flare Q+ Rayzr 102 Operation Manual

Flare Q+ RZ
Operation Manual
TMB 24/7 Technical Support
US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 e-mail: techsupport@tmb.com
2
Overview
Solaris Flare indoor LED fixtures are combination wash/str obe/b li nders with class-leading LED RGBW brightness with greater than 9,5 00 lumens (Rayzr 50 cm) and greater than 19,500 lumens (Rayzr 100 cm). Features include instant color mixing and 1200Hz refresh rate for smooth on-camera dimming. Q+ technology increases the brightness with virtuall y no additiona l fan noise.
Note: Solaris Flare Rayzr Q+ 50 cm has two cooling fans and one safety hitch.
3
Specifications
Solaris Flare Q+ Rayzr
50 cm
100 cm
Light sources
18 CREE© LEDs
(divided in to 6 pixels)
36 CREE© LEDs
(divided in to 12 pixels)
Beam Spread
36°, optional beam angles available: 20°, 54°, and 70°
Colors
R, G, B, W
Average color wavelength
(manufacturer rated)
Red: 625 nm, Green: 530 nm, Blue: 460 nm, White: >5700K
Refresh rate
1200 Hz
Intensity control
16-bit or 8-bit
Operating Voltage
100-240VAC 50/60Hz
Fuse
2A 250V slow-blow (5x20mm)
4A 250V slow-blow (5x20mm)
Cooling
Air cooling + fan
Operating temperature
-4 °F - +104 °F (-20 °C - +40 °C)
DMX channels
3-32 depending on control mode
3-56 depending on control mode
DMX connectors
Input 5-pin XLR male, Thru 5-pin XLR female
DMX pin configuration
pin 1 shield, pin 2 (data-), pin 3 (data+), pin 4 n/a, pin 5 n/a
Max. power draw
200 W
400 W
RDM support
Yes
Power Connector Input
PowerCON 20A blue
Fixing
Adjustable yoke
Unit Dimensions (LxWxH)
19.92 x 1.61 x 5.76 in
(506 x 41 x 146,5 mm)
39.60 x 1.61 x 5.76 in
(1006 x 41 x 146,5 mm)
Shipping Dimensions (LxWxH)
22.25 x 7.67 x 10.62 in
(565 X 195 X 270 mm)
41.92 x 7.67 x 10.62 in
(1065 X 195 X 270 mm)
Unit Weight
8.16 lb. (3,7 kg)
13.89 lb. (6,3 kg)
Shipping weight
10.58 lb. (4,8 kg)
15.65 lb. (7,1 kg)
4
Unpacking Instructions
Upon receipt of the fixture, carefully unpack the carton and check the contents to ensure that all parts are present and in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling. Save the carton and all packing materials. If a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Power Requirements
Before powering the unit, make sure the line voltage is within the range of accepted voltages. Fixtures operating voltage is 100-240 VAC 50/60Hz. All fixtures must be powered directly from a switched circuit and cannot be operated with a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely as a 0-100% switch.
When powered up, Solaris performs a preprogrammed internal test. On initial power-up the factory default DMX address appears on the display screen and Solaris is ready for operation. After initial power-up, the last­saved DMX address will appear.
Frequency Settings
Depending on location, change the Default Frequency setting to match the mains power (e.g., US and Canada should be set at 60Hz). Proper frequency setting will ensure minimum number of visible artifacts when using Solaris on camera.
Safety Instructions
Please keep this Operation Manual for future reference. If the unit is sold to another user, make sure they also receive this instruction booklet.
Ensure fixture is connected to proper voltage, and that line voltage is not higher than that stated on the fixture.
Make sure there are no flammable materials close to the u nit w hi le operating.
Always disconnect from the power source before servicing or fuse replacement. Always use the fuse specified in this manual.
Always use a safety cable when hanging fixture overhead.
Maximum ambient temperature (Ta) is 40°C (104°F). Do not operate fixture at temperatures above this rating.
In the event of a serious operating problem, stop using the unit immediately. Repairs must be carried out by trained, authorized personnel. Contact the nearest authorized technical assistance center. Only OEM spare parts should be used.
Do not connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source during operation.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your distributor.
Please read these instructions carefully. This user guide contains essential information about the installation, usage and maintenance of this fixture.
5
Dimensions
Solaris Flare Q+ Rayzr 50 cm
Dimensions in inches (mm)
Solaris Flare Q+ Rayzr 100 cm
Dimensions in inches (mm)
6
Setup
Fuse Replacement
1. Flare Q+ Rayzr devices use a slow-blow fuse (5x20mm).
Flare Q+ Rayzr 50 uses a 2A 250V fuse
Flare Q+ Rayzr 100 uses a 4A 250V fuse
To replace a Fuse:
2. With a screwdriver turn the fuse cap counter-clockwise to remove fuse cap with fuse.
3. Replace fuse attached to fuse cap.
4. Reinsert fuse cap with new fuse and tighten clockwise.
Power Linking
Solaris Flare Q+ Rayzr has Neutrik® PowerCon IN and THRU connections allowing power linking (daisy-chaining). Depending on the power provided, you should not ex c eed the po wer thres ho ld.
Max. 5 units 100-120V; max. 10 units 208-240V for Flare Q+ Rayzr 50cm. Max. 3 units 100-120V; max. 6 units 208-240V for Flare Q+ Rayzr 100cm.
Fixture Linking
A DMX data link is needed to operate one or more fixtures via a DMX-512 lighting console. The combined number of channels required b y al l t he f ixtur es on a D MX data link det ermines the number of fixtures the DMX da ta l i nk can support.
Important: Fixtures on a DMX da ta link must be daisy-chained in o ne single line. To comply with th e EIA­485 standard, no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance between fixtures: 984 ft. (300 meters).
Disconnect the power cord before replacing the fuse. Always replace with the correct fuse type.
7
Setting up a DMX Serial Data Link
1)
Connect the male 5-pin XLR connector of the data cable to the female 5-pin XLR output of the DMX console. Connect the other end of the data cable (female 5-pin XLR) to the male 5-pin XLR connector located on the Solaris Flare.
2)
Connect from the fixture output as stated above to the input of the following fixture.
3)
Continue linking until the last fixture is connected in your DMX signal data chain.
8
Fixture Mounting
Orientation
Flare Q+ Rayzr fixtures may be m ounted in any position. Each h ave a yoke with mounting hol e for clamps or couplers. Always make sure there is adequate room for ventilation. Do not obstruct the unit’s fan or vents.
Rigging
To avoid possibility of risk, both Rayzr fixtures comes wit h a hitch to be used with safety cables. Always consult a certified rigging specialist before suspending any fixture overhead!
Use ProBurger
®
couplers or equivalent C - or O-type clamps for att aching to truss . It is im portant never to o bstruc t the fan or vents pathway. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs.
Note!
Always use safety cables!
When selecting installation location, consider routine maintenance.
Never mount fixture where it will be exposed to moisture, excessive humidity, ex treme temperatures, or
restricted ventilation.
9
Fixture accessories
Dimensions in inch (mm)
Rayzr Joining Adapter
Unit Weight: 0.44 lb. (0,2 kg)
Maximum vertical length for joined Rayzrs is 5 meters
10
Rayzr Hanging Adapter
Unit Weight: 0.57 lb. (0,26 kg)
Loading...