TMB PCCAT6AP User Manual

CAT6a Ethernet Cable
PCCAT6AP
Applications
Flexible cable for digital, communication and local area network, indoor and outdoor use, harsh environmental applications, and high data rates.
General construction
The cable includes 4 twisted
pairs, special central ller unit and
Aramid in SF/UTP structure and an industrial grade PU compound jacket.
General Specications
Conductors 24 AWG (0.25 mm2) 7x0.2 mm stranded bare copper. Insulation Solid PO, Nom. Diameter 0.047” [1.2 mm]
Pairs
Assembly
Shields
Jacket
Marking ProPlex PCCAT6AP Cat.6A SF/UTP Data Cable [+batch number] Weight 50.4 lbs./mft (75 Kg/Km)
Temperature Range Bending Radius 75 mm min.
Typical Operational Installation Length
Tensile Force 150 N max.
Compliance
Colour Coded singles twisted into pairs Colour Code: White X Blue; White X Orange; White X Green; White X Brown
4 pairs cabled together with a special shaped central ller member, overall wrapped with non-
woven PET, overall braided with Aramid strength members and overall shielded Aluminium foil, 100% coverage with 30% overlap, metal face out.
Tinned copper braid, 80% nom coverage. Material: Industrial grade PU compound
OD: 8.3 mm +/- 0.3 mm
Colour: Black
Working: -40°C to +70°C
Up to 85 m (20°C)
Flame test: IEC 60332.1
Environmental: per IEC 61156-6 and ISO/IEC 11801
RoHS compliance: 2002/95/EC
Innovave, Performance-Driven Show Technology Since 1983
Los Angeles
+1 818-899-8818
London
+44 (0)20-8574-9700
New York
+1 201-896-8600
© 2017, TMB. All rights reserved. LITPPXCAT6APA4 – Effective: 4 August 2017
Specications are subject to change without notice. This information supersedes all previously supplied information.
Beijing
tmb.com
Toronto
+1 519-538-0888
Jacket
NW Tape
+ Aramid braid
Pairs
Braid Shield
Aluminium Foil
Central shaped ller
Electrical Specications
Dielectric Strengtrh 500 Vrms/min. Pair Mutual Capacitance 42 pF/m Capacitance Unbalance 1.4 pF/m (800 Hz) Pair characteristic impedance 100 +/- 5 Ohm
NVP (Nominal Velocity of Propagation) 66 % Max skew delay 25 nSec/100m
Conductor DC resistance (20° C) Resistance unbalance (within pairs) 2% max. Insulation resistance Not less than 5 GΩ-km Alien cross talk Proven by design per IEC 61156-6 Coupling Attenuation Type I per IEC 61156-6 Transfer impedance Grade 1 per IEC 61156-6 Transverse conversion loss (TCL) Level A per IEC 61156-6
93 Ohm
Transmission Performance
Freq. MHz
1 2.4 72.3 75.3 20 67 65 68 4 4.2 63.3 66.3 23 67 53 56 10 6.4 57.3 60.3 25 67 45 48 20 9.1 52.8 55.8 25 67 39 42 30 11.5 50.1 53.1 23.8 67 35.4 38.4 100 21.4 42.3 45.3 21.1 62.5 25 28 150 26.6 39.7 42.7 18.8 59.8 21.5 24.5 200 50.5 37.8 40.8 18 58 19 22 250 34.3 36.3 39.3 17.3 56.5 17 20 300 37.7 35.1 38.1 17.3 55.3 15.5 18.5 400 44.5 33.3 36.3 17.3 53.4 13 16 500 50.5 31.8 34.8 17.3 52 11 14
ProPlex CAT6a Ethernet cables (w/copper conductor) meets attenuation specs up to 85m (275 ft).