![](/html/79/7978/79789d073bfb0fef71cf808eb63a7230ce9324551f30be998790376df1dae0c2/bg1.png)
©2004 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED P/N: 8504123
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
950-0745 SS1C PRESSURE SWITCH BLEED ORIFICE KIT
In order for the SideShot SS1C pressure switch to function properly for the intended application, the proper bleed orifice has to be
selected as determined below.
1. Upon installation, if the vent connector length is less than 3.1 equivalent meters (10 feet), then the smaller
opening #52 bleed orifice should be used.
2. Upon installation, if the vent connector length is greater than 3.1 equivalent meter (10 feet), then the larger
opening #40 bleed orifice should be used.
3. Once proper bleed orifice has been determined, install into the Bleed Orifice port as indicated.