TJERNLUND 950-0018 SS2 HIGH LIMIT KIT 8504071 REV. 0398, 950-0018, SS2 User Manual

TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
MODEL (950-0018) SS2 REPLACEMENT HIGH LIMIT INSTRUCTIONS
READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION
Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. NOTE: The High Limit Switch you are replacing may not be defective. Depress reset button on High Limit as noted in troubleshooting guide
in the SS2 instructions or junction box label on back of SS2. Call us toll free at 1-800-255-4208 if you are unsure if the High Limit is defective.
1. Remove vent pipe and SS2 inlet pipe by twisting counter clockwise.
2. Remove (9) screws from rear and bottom of vent cabinet.
4. Remove (2) wires and (2) screws from High Limit Switch.
5. Remove defective High Limit Switch from SS2.
6. Follow the above steps in reverse order for reassembly of new High Limit Switch and SS2.
7. Reestablish power and run SS2 & appliance through a couple of heating cycles to verify proper operation.
HIGH LIMIT
Rev. 3/98 Copyright © 1998, Tjernlund Products, Inc. All rights reserved. P/N 8504071