![](/html/fd/fd80/fd8023333a55e893dba240d63d872f7c243652fe588d9bb5bf2cfb06a0830477/bg1.png)
OWNERS INSTRUCTIONS
THESE INSTRUCTIONS
MUST REMAIN
WITH EQUIPMENT
DO NOT DESTROY
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (651) 426-2993 • (800) 255-4208 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
MODEL VH1 SERIES VENT HOODS 6”, 8”, 10”
The VH1-8 and VH1-10 do not have a secondary heat shield. A thimble will have to be added to maintain clearances to
combustibles if penetrating a combustible wall with these models.
1. Terminate the vent system so that proper minimum clearances are maintained as cited in the latest edition of the
National Fuel Gas Code (NFPA # 54) and the latest edition of NFPA #211, or as follows:
• Not be less than 7 feet above grade when located adjacent to public walk ways
• At least 3 feet above any forced air inlet located within 10 feet
• At least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into any building
• At least 12 inches above grade.
THE MANUFACTURER ALSO RECOMMMENDS:
• The vent terminal shall also not be installed closer than 3 feet from the inside corner of an L-shaped structure
• Not less than 2 feet from an adjacent building
• Flue gases are not directed so as to jeopardize people, overheat combustible structures or enter buildings
2. Check vent pipe system for leakage. All vent pipe joints on “positive” side of power venter must be sealed.
3. A vent system incorporating a Tjernlund VH1 Series vent hood should not exceed 550oF. gross.
4. Termination of a sidewall vent system with a device other than the Tjernlund VH1 vent hood could affect system
performance and result in a possible safety hazard.
5. Plan the vent system layout to avoid the possibility of accidental contact with concealed wiring or plumbing inside walls.
6. Installation must be done by one experienced and familiar with venting of combustion gases.
SIDE VIEW FRONT VIEW
SIDE VIEW FRONT VIEW
![](/html/fd/fd80/fd8023333a55e893dba240d63d872f7c243652fe588d9bb5bf2cfb06a0830477/bg2.png)
The VH1-8 and VH1-10 do not have a secondary heat shield. A thimble will have to be added to maintain clearances to
combustibles if penetrating a combustible wall with these models.
1. Use inside wall cover plate as a template to mark a hole on appropriate place on wall. Cut hole 1/2” larger to facilitate
installation.
2. Slide hood through opening from outside. Fasten the vent hood with provided anchors and screws.
3. Install cover plate and fasten to inside wall with provided anchors and screws.
4. Seal all vent pipe connections between the Power Venter and vent hood with high-temperature silicone sealant or metal
tape to prevent flue gas leakage.
MAINTENANCE
The vent system must be inspected regularly. Points of inspection are as follows.
1. Screened opening of the vent hood should be free from foreign material and cleaned as necessary.
2. Structural integrity of the vent hood should be maintained so as not to reduce vent discharge opening.
3. Check all vent system connections for leakage and re-seal where needed. If any vent pipe shows signs of deterioration,
replace immediately and check new connections for possible leaks. Re-seal with high-temperature silicone sealant or
metal tape to prevent flue gas leakage.
TJERNLUND LIMITED ONE YEAR WARRANTY
Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE
FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS
LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty
lasts, so that limitation may may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not
apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Send all inquiries regarding warranty work to Tjernlund Products, Inc.
1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 or email us at fanmail@tjfans.com.
P/N 8504054 ©2000, Tjernlund Products, Inc. REV. B 9/00