STEP 1: TTMEBRIDGEV2-RSData Preparation
Connect the serial cable adapter (black end) to either black port on the TTMEBRIDGEV2-RSData. Plug the serial cable into the serial TTMEBRIDGEV2­RSData cable adapter. Ensure the screws on all serial connections are tight.
STEP 2: TT33003G and TTMEBRIDGEV2-RSData Installation
Connect the TT33003G to the TTMEBRIDGEV2-RSData (see the diagram for correct connections) using the supplied harnesses. Connect the serial cable to the spreader control so the wiring is secure and will not be damaged. Install both the TT33003G and TMEBRIDGEV2-RSData devices in a secure position where they will not be subject to moisture damage and cannot easily be found (preferably under the dash).
Ensure the TT33003G is installed flat with the correct side pointing skyward with no metal blocking the unit from the sky. DO NOT install the devices closer than 18 inches to the vehicle’s radio or BCM( Body Control Module).
For Live Tech Support:
Call Certified Tracking Solutions at 1-780-391-3800.
8AM to 6PM Monday to Friday MST
www.TitanGPS.ca
Primary Wire connections
The supplied harness comes pre assembled to give power to both the TT33003G and the TTMEBRIDGEV2-RSData.
TT33003G
TTMEBRIDGEV2-RSData
Black: Ground
Red: 12 Volts (Constant)
White: Ignition (MUST be a true ignition
source)
Black: Ground
Red: 12 Volts (Constant)
GROUND MUST BE CONNECTED DIRECTLY TO THE CHASSIS WITH PAINT REMOVED
STEP 3: Call to test
Call Certified Tracking Solutions at 1-780-391-3800 to test the modem to ensure it is reporting correctly. This MUST be done to ensure proper installation. The hours of operation are Monday to Friday, 8am to 6pm MST.
Confirm LED Status
LED Color Type LED Action Description
Blue Cellular
Double Blinks Indicates device has connected to the
cellular network
Green
GPS Blinking Indicates device has obtained a valid
GPS signal
Spreader Controls
Accucast 7000/7500 - Connection at back of cab to serial connection.
REV032316
QUICK INSTALL GUIDETT33003G TTMEBRIDGE2 - RSDATA
RED - 12V
Constant 12V
BROWN - TX
BLUE - RX
GREEN - Starter Disable
BLACK - GND
True Ignition
WHITE - True Ignition
Serial of TTMEBRIDGEV2-RSData to Output of Plow Spreader Data
*Either connector works
TT3300 3G
GND
Red
Black
Brown
Blue
TTMEBRIDGEV2-RSData
Sections in diagram that are enlarged need to be connected
TTMEBRIDGEV2-RSData Wiring Diagram