This manual contains information that must be read and
understood before using the equipment. When you come to an
area that has one of the following symbols, pay particular
attention and make certain to heed the safeguard.
This symbol indicates a potential hazard that may cause
serious injury or loss of life. Important safety information will
follow.
This symbol indicates a potential hazard to you or to the
equipment. Important information that tells how to prevent
damage to the equipment or how to avoid causes of minor
injuries will follow.
NOTE: Notes give important information which should
be given special attention.
WARNING
HAZARD: Injection injury - A high pressure stream
produced by this equipment can pierce the skin
and underlying tissues, leading to serious
injury and possible amputation. See a
physician immediately.
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE CUT!
Injection can lead to amputation. See a physician
immediately.
The maximum operating range of the sprayer is 3200
PSI/221BAR fluid pressure.
PREVENTION:
• NEVER aim the gun at any part of the body.
• NEVER allow any part of the body to touch the fluid stream.
DO NOT allow body to touch a leak in the fluid hose.
• NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
•ALWAYS lock the gun trigger, shut the sprayer off, and
release all pressure before servicing, cleaning the tip or
guard, changing tip, or leaving unattended. Pressure will
not be released by turning off the motor. The
PRIME/SPRAY valve must be turned to PRIME to relieve
the pressure. Refer to the PRESSURE RELIEF
PRESSURE described in the sprayer manual.
•ALWAYS keep the tip guard in place while spraying. The
tip guard provides some protection but is mainly a warning
device.
•ALWAYS remove the spray tip before flushing or cleaning
the system.
• The paint hose can develop leaks from wear, kinking and
abuse. A leak can inject material into the skin. Inspect
the hose before each use.
•NEVER use a spray gun without a trigger lock and trigger
guard in place and in good working order.
• All accessories must be rated at or above 3200 PSI/221
BAR. This includes spray tips, guns, extensions, and
hose.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury. It is
important to treat the injury as soon as possible. DO
NOT delay treatment to research toxicity. Toxicity is a
concern with some coatings injected directly into the
blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.
HAZARD: EXPLOSION OR FIRE - Solvent and paint fumes
can explode or ignite. Severe injury and/or
property damage can occur.
PREVENTION:
• Provide extensive exhaust and fresh air introduction to
keep the air within the spray area free from accumulation
of flammable vapors.
•Avoid all ignition sources such as static electric sparks,
open flames, pilot lights, and hot objects. Connecting or
disconnecting power cords or working light switches can
make sparks.
•Do not smoke in spray area.
• Fire extinguisher must be present and in good working
order.
• Place paint sprayer at a minimum of 3 feet (preferably
more) into a separate, well ventilated room from the spray
object or at least 20 feet from the spray object in a well
ventilated area (add more hose if necessary). Flammable
vapors are often heavier than air. Floor area must be
extremely well ventilated. The paint sprayer contains
arcing parts that emit spark and can ignite vapors.
• The equipment and objects in and around the spray area
must be properly grounded to prevent static sparks.
• Use only conductive or grounded high pressure fluid hose.
Gun must be grounded through hose connections.
• Power cord must be connected to a grounded circuit.
• Always flush unit into a separate metal container, at low
pump pressure, with spray tip removed. Hold gun firmly
against side of container to ground container and prevent
static sparks.
• Follow the material and solvent manufacturer's warnings
and instructions.
• Use extreme caution when using materials with a
flashpoint below 70° F (21° C). Flashpoint is the
temperature that a fluid can produce enough vapors to
ignite.
• Plastic can cause static sparks. Never hang plastic to
enclose a spray area. Do not use plastic drop cloths
when spraying flammable materials.
• Use lowest possible pressure to flush equipment.
Always place sprayer outside of structure in fresh air. Keep all
solvents away from the engine exhaust. Never fill fuel tank
with a running or hot engine. Hot surface can ignite spilled
fuel. Always attach ground wire from sprayer unit to a
grounded object, such as a metal water pipe. Refer to engine
owner’s manual for complete safety information.
HAZARD: EXPLOSION HAZARD DUE TO INCOMPATIBLE
MATERIALS - Will cause severe injury or
property damage.
PREVENTION:
• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as
mildewcide, methylene chloride and 1,1,1 trichloroethane. They are not compatible with aluminum.
• Contact your coating supplier about the compatibility of
material with aluminum.
HAZARD: HAZARDOUS VAPORS - Paints, solvents,
insecticides, and other materials can be
harmful if inhaled or come in contact with the
body. Vapors can cause severe nausea,
fainting, or poisoning.
PREVENTION:
• Use a respirator or mask if vapors can be inhaled. Read
all instructions supplied with the mask to be sure it will
provide the necessary protection.
•Wear protective eyewear.
•Wear protective clothing as required by coating
manufacturer.
HAZARD: GENERAL - This product can cause severe
injury or property damage.
PREVENTION:
• Read all instructions and safety precautions before
operating equipment.
• Always disconnect the motor from the power supply
before working on the equipment.
• Follow all appropriate local, state, and national codes
governing ventilation, fire prevention, and operation.
• The United States Government Safety Standards have
been adopted under the Occupational Safety and Health
Act (OSHA). These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards, should be consulted.
• Use only manufacturer authorized parts. User assumes
all risks and liabilities when using parts that do not meet
the minimum specifications and safety devices of the
sprayer manufacturer.
• Before each use, check all hoses for cuts, leaks, abrasion
or bulging of cover. Check for damage or movement of
couplings. Immediately replace the hose if any of these
conditions exist. Never repair a paint hose. Replace it
with another grounded high-pressure hose.
• All hoses, swivels, guns, and accessories must be
pressure rated at or above 3200PSI/221 BAR.
• Do not spray outdoors on windy days.
•Wear clothing to keep paint off skin and hair.
Grounding Instructions
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
DANGER — Improper installation of the grounding plug can
result in a risk of electric shock. If repair or replacement of the
cord or plug is necessary, do not connect the green grounding
wire to either flat blade terminal. The wire with insulation
having a green outer surface with or without yellow stripes is
the grounding wire and must be connected to the grounding
pin.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product is properly grounded.
Do not modify the plug provided. If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated below. A
temporary adapter which looks like the adapter illustrated in
the figure below may be used to connect this plug to a 2 pole
receptacle as shown if a properly grounded outlet is not
available.
The temporary adapter should be used only until a properly
grounded outlet as shown below can be installed by a qualified
electrician. The green colored rigid ear, lug, or the grounding
wire extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box
cover. Whenever the adapter is used, it must be held in place
by a metal screw.
CAUTION
Use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept the
plug on the product. Make sure your extension cord is in
good condition. When using an extension cord, be sure
to use one heavy enough to carry the current your
product will draw. An undersized cord will cause a drop
in line voltage resulting in loss of power and overheating.
A 12 gauge cord is recommended. If an extension cord is
to be used outdoors, it must be marked with the suffix WA after the cord type designation. For example, a
designation of SJTW-A would indicate that the cord would
be appropriate for outdoor use.
This piston pump is a precision power tool used for spraying
many types of materials. Read and follow this instruction
manual carefully for proper operating instructions,
maintenance, and safety information.
Preparing a New Sprayer
If this unit is new, it is shipped with test fluid in the fluid section
to prevent corrosion during shipment and storage. This fluid
must be thoroughly cleaned out of the system with mineral
spirits before you begin spraying.
Siphon
Hose
Return
Tube
Electrical
Box
Filter
Outlet
Fitting
Motor
Pressure
Control
Knob
PRIME/
SPRAY
Val ve
Fluid
Section
Operation
WARNING
This equipment produces a fluid stream at extremely high
pressure. Read and understand the warnings in the
Safety Precautions section at the front of this manual
before operating this equipment.
Setup
Perform the following procedure before plugging in the power
cord of an electric unit.
1. Ensure that the suction set and the return hose are
attached and secure.
2. Attach a minimum of 50’ of nylon airless spray hose to the
unit.
3. Attach an airless spray gun to the spray hose. Do not
attach the tip to the spray gun yet. Remove the tip if it is
already attached.
WARNING
Make sure all airless hoses and spray guns are electrically
grounded and rated for at least 3200 psi (220 bar) fluid
pressure.
4. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
5. Make sure the ON/OFF switch is in its OFF position.
6. Fill the wet cup with one tablespoon of piston seal
lubricant (Piston Lube).
Never operate unit for more than ten seconds without
fluid. Operating this unit without fluid will cause
unnecessary wear to the packings.
7. Make sure the electrical service is 120V, 15 amp
minimum.
8. Plug the power cord into a properly grounded outlet at
least 25’ from the spray area.
CAUTION
Always use a minimum 12 gauge, three-wire extension cord
with a grounded plug. Never remove the third prong or use
an adapter.
Always keep the trigger lock on the spray gun in the
locked position while purging the system.
1. Place the suction tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
4. Move the PRIME/SPRAY valve down to the PRIME
position.
5. Turn the unit on by moving the ON/OFF switch to the ON
position.
6. Slowly turn the pressure control knob clockwise to
increase the pressure until fluid starts to come out of the
return hose. Use only enough pressure to keep the fluid
coming out.
7. Allow the sprayer to run for 15–30 seconds to flush the
test fluid out through the return hose and into the waste
container.
8. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
9. Turn the unit off by moving the ON/OFF switch to the OFF
position.
Preparing to Paint
Before painting, it is important to make sure that the fluid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer’s fluid section.
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
1. Place the suction tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
2. Place the return hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
4. Move the PRIME/SPRAY valve down to the PRIME
position.
5. Turn the unit on by moving the ON/OFF switch to the ON
position.
6. Slowly turn the pressure control knob clockwise to
increase the pressure until fluid starts to come out of the
return hose. Use only enough pressure to keep the fluid
coming out.
7. Allow the sprayer to run for 15–30 seconds to flush the old
solvent out through the return hose and into the metal
waste container.
8. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
9. Turn the unit off by moving the ON/OFF switch to the OFF
position.
NOTE: Make sure that the spray gun does not have a
tip or tip guard installed.
10. Move the PRIME/SPRAY valve up to the SPRAY position.
12. Unlock the gun by turning the gun trigger lock to the
WARNING
Trigger lock
in locked position.
WARNING
WARNING
WARNING
unlocked position.
11.Unlock the gun by turning the gun trigger lock to the
unlocked position.
WARNING
Ground the gun by holding it against
the edge of the metal container while
flushing. Failure to do so may lead to
a static electric discharge, which may
cause a fire.
13. Trigger the gun into the metal waste
container.
14. Slowly turn the pressure control knob clockwise to
increase the pressure until fluid starts to come out of the
gun. Use only enough pressure to keep the fluid coming
out.
15. Continue to trigger the gun until the old solvent is gone
and fresh solvent is coming out of the gun.
16. Lock the gun by turning the gun
trigger lock to the locked position.
17. Set down the gun and increase the
pressure by turning the pressure
control knob slowly clockwise.
18. Check the entire system for leaks.
If leaks occur, follow the “Pressure
Relief Procedure” in this manual
before tightening any fittings or hoses.
19. Follow the “Pressure Relief Procedure” in this manual
before changing from solvent to paint.
Be sure to follow the pressure relief procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for cleanup.
Painting
1. Place the suction tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Turn the pressure control knob fully counterclockwise to
its lowest pressure setting.
4. Move the PRIME/SPRAY valve down to the PRIME
position.
5. Turn the unit on by moving the ON/OFF switch to the ON
position.
6. Slowly turn the pressure control knob clockwise to
increase the pressure until paint starts to flow out of the
return hose into the metal waste container. Use only
enough pressure to keep the paint coming out.
7. Turn the unit off by moving the ON/OFF switch to the OFF
position.
8. Remove the return hose from the waste container and
place it in its operating position above the container of
paint.
9. Move the PRIME/SPRAY valve up to the SPRAY position.
10. Turn the unit on.
Ground the gun by holding it against
the edge of the metal container while
flushing. Failure to do so may lead to
a static electric discharge, which may
cause a fire.
12. Trigger the gun into the metal waste
container until all air and solvent is flushed from the spray
hose and paint is flowing freely. from the gun.
13. Lock the gun by turning the gun
trigger lock to the locked position.
14. Turn the unit off.
15. Attach tip guard and tip to the gun
as instructed by the tip guard or tip
manuals.
POSSIBLE INJECTION HAZARD. Do not spray without the
tip guard in place. Never trigger the gun unless the tip is
in either the spray or the unclog position. Always engage
the gun trigger lock before removing, replacing or
cleaning tip.
16. Turn the unit on.
17. Increase the pressure by turning the pressure control
knob slowly clockwise and test the spray pattern on a
piece of cardboard. Adjust the pressure control knob until
the spray from the gun is completely atomized.
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear
and additional overspray.
Trigger lock
in locked position.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for cleanup.
1. Lock the gun by turning the gun
trigger lock to the locked position.
2. Turn the unit off by moving the
ON/OFF switch to the OFF position.
3. Turn the pressure control knob fully
counterclockwise to its lowest
pressure setting.
4. Unlock the gun by turning the gun
trigger lock to the unlocked position.
5. Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any
pressure that may still be in the hose.
7. Lock the gun by turning the gun trigger lock to the locked
position.
8. Move the PRIME/SPRAY valve down to the PRIME
position.
POSSIBLE INJECTION HAZARD. Do not spray without the
tip guard in place. Never trigger the gun unless the tip is
in either the spray or the unclog position. Always engage
the gun trigger lock before removing, replacing, or
cleaning tip.
Spraying Technique
The following techniques, if followed, will assure professional
painting results.
Hold the gun perpendicular to the surface and always at equal
distance from the surface. Depending on the type of material,
surface, or desired spray pattern, the gun should be held at a
distance of 12 to 14 inches (30 to 35 cm).
Move the gun either across or up and down the surface at a
steady rate. Moving the gun at a consistent speed conserves
material and provides even coverage. The correct spraying speed
allows a full, wet coat of paint to be applied without runs or sags.
Holding the gun closer to the surface deposits more paint on
the surface and produces a narrower spray pattern. Holding
the gun farther from the surface produces a thinner coat and
wider spray pattern. If runs, sags, or excessive paint occur,
change to a spray tip with a smaller orifice. If there is an
insufficient amount of paint on the surface or you desire to
spray faster, a larger orifice tip should be selected.
Maintain uniform spray stroke action. Spray alternately from
left to right and right to left. Begin movement of the gun before
the trigger is pulled.
Avoid arcing or holding the gun at an angle. This will result in
an uneven finish.
Offspray
Too Thick
ArcingGun at angle
Proper lapping (overlap of spray pattern) is essential to an
even finish. Lap each stroke. If you are spraying horizontally,
aim at the bottom edge of the preceding stroke, so as to lap
the previous pattern by 50%.
For corners and edges,
split the center of the
spray pattern on the
corner or edge and spray
vertically so that both
adjoining sections receive
approximately even
amounts of paint.
If conditions are windy, angle the
spray pattern into the wind to
minimize drifting. Work from
ground to roof. Do not attempt
to spray if wind is excessive.
When spraying with a shield,
hold it firmly against the surface. Angle the spray gun slightly
away from the shield and toward the surface. This will prevent
paint from being forced underneath.
Shrubs next to houses should be tied back and covered with a
canvas cloth. The cloth should be removed as soon as
possible. Titan gun extensions are extremely helpful in these
situations.
Nearby objects such as automobiles, outdoor furniture, etc.
should be moved or covered whenever in the vicinity of a
spray job. Be careful of any other surrounding objects that
could be damaged by overspray.
Practice
1. Be sure that the paint hose is free of kinks and clear of
objects with sharp cutting edges.
2. Turn the pressure control knob counterclockwise to its to
its lowest setting.
3. Turn the PRIME/SPRAY valve up to its SPRAY position.
4. Turn the pressure control knob clockwise to its highest
setting. The paint hose should stiffen as paint begins to
flow through it.
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to
check the spray pattern.
8. Use the lowest pressure
setting necessary to get a
good spray pattern. If the
pressure is set too high, the
spray pattern will be too light.
If the pressure is set too low,
tailing will appear or the paint
will spatter out in gobs rather
than in a fine spray.
Special cleanup instructions for use with flammable
solvents:
•Always flush spray gun preferably outside and at least one
hose length from spray pump.
• If collecting flushed solvents in a one gallon metal
container, place it into an empty five gallon container, then
flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
The pump, hose, and gun should be cleaned thoroughly
after daily use. Failure to do so permits material to cake,
seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun nozzle tip
removed when using mineral spirits or any other solvent
to clean the pump, hose, or gun. Static electricity buildup
may result in a fire or explosion in the presence of
flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the suction tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to its PRIME
position.
6. Turn the unit on by moving the ON/OFF switch to the ON
position.
7. Slowly turn the pressure control knob clockwise to
increase the pressure until fluid starts to come out of the
return hose. Use only enough pressure to keep the fluid
coming out.
8. Allow the solvent to circulate through the unit and flush
the paint out of the return hose into the metal waste
container.
9. Turn the unit off by moving the ON/OFF switch to the OFF
position.
10. Move the PRIME/SPRAY valve up to its SPRAY position.
11.Turn the unit on.
Ground the gun by holding it against
the edge of the metal container while
flushing. Failure to do so may lead to
a static electric discharge, which may
cause a fire.
12. Trigger the gun into the metal waste
container until the paint is flushed out of the hose and
solvent is coming out of the gun.
13. Continue to pull and release the trigger until the solvent
coming out of the gun is clean.
NOTE: Pulling and releasing the trigger of the spray
gun creates a “pulsing” action that cleans out
the hose and the spray gun more effectively.
NOTE: For long-term or cold weather storage, pump
mineral sprits through the entire system.
For short-term storage when using latex paint,
pump water mixed with Titan Liquid Shield
through the entire system (see the Accessories
section of this manual for part number).
14. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
15. Unplug the unit and store in a clean, dry area.
Do not store the unit under pressure.
Maintenance
Before proceeding, follow the Pressure Relief Procedure
outlined previously in this manual. Additionally, follow all
other warnings to reduce the risk of an injection injury,
injury from moving parts or electric shock. Always unplug
the sprayer before servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
1. Before repairing any part of the sprayer, read the
instructions carefully, including all warnings.
CAUTION
Never pull on a wire to disconnect it. Pulling on a wire
could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to
be sure that the problem is corrected. If the sprayer does
not operate properly, review the repair procedure to
determine if everything was done correctly. Refer to the
Troubleshooting section to help identify other possible
problems.
3. Make certain that the service area is well ventilated in
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
4. If you have any further questions concerning your TITAN
Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................1-800-526-5362
2. Loosen and remove the four rear cover screws. Remove
the rear cover.
3. Remove the cover plate and the insulator plate on the
pump housing by removing the corresponding four
screws.
4. Disconnect the white motor wire from the white power
cord wire and the black motor wire from the motor starter.
Position the disconnected wires so they can slide easily
through the rear bearing housing assembly when the
motor housing is removed.
5. Loosen and remove the four motor mounting screws.
6. Carefully remove the motor housing so that the two motor
wires slide through the rear bearing housing one at a time.
Be careful not to lose the spring washer as it sits loosely
on the end of the armature.
7. Remove the armature from the pump housing by pulling
up on the armature. Inspect the pinion on the old
armature. If damaged, the pinion gear in the pump
housing must be replaced also.
8. Install the new motor assembly into the pump housing.
Make sure that the motor wires are fed through the rear
bearing housing and into the pump housing one at a time
during installation.
9. Before securing the motor, make sure that the motor wires
are completely free of the motor and have been fed
properly into the pump housing.
10. Secure the motor housing with the four motor mounting
screws.
11. Slide the rear cover over the motor with the air vent facing
down. Secure the rear cover with the four rear cover
screws.
12. Connect the “male” white motor wire to the “female” white
power cord wire. Connect the black motor wire to position
#2 on the motor starter.
13. Place the insulator plate and the cover plate on the pump
housing and secure in position using the corresponding
four screws.
Rear Cover
End Cap
Brush Clamp
Motor Brush
and Tube
Motor Housing
Motor Wires
Replacing the Motor Brushes
1. Loosen and remove the rear cover screws. Remove the
rear cover.
2. Loosen and remove the end cap screws. Remove the
end cap.
3. Loosen and remove the brush clamp screws. Remove the
brush clamps.
4. Disconnect the wire lead to the motor brushes. Remove
the motor brush.
5. Reassemble in reverse order using the new motor
brushes.
Replacing the Gears
1. Loosen and remove the four front cover screws. Remove
the front cover.
2. Remove the cover plate and the insulator plate on the
pump housing by removing the corresponding four
screws.
3. Disconnect the white motor wire from the white power
cord wire and the black motor wire from the motor starter.
Position the disconnected wires so they can slide easily
through the rear bearing housing assembly when the
motor housing is removed.
4. Loosen and remove the four rear cover screws. Remove
the rear cover.
5. Loosen and remove the four motor mounting screws.
6. Carefully remove the motor housing and armature so that
the two motor wires slide through the rear bearing housing
one at a time. Be careful not to lose the spring washer as
it sits loosely on the end of the armature.
7. Inspect the gears on the armature for damage or
excessive wear. Replace the motor assembly if
necessary.
8. Loosen and remove the three rear bearing housing
screws.
9. Using a rubber mallet, carefully tap the front of the
crankshaft that extends through the connecting rod. This
will dislodge the rear bearing housing from the pump
housing. Remove the rear bearing housing.
10. Inspect the gears for damage or excessive wear. Replace
if necessary.
11. Reassemble the pump by reversing the above steps.
During reassembly, make sure all washers are in place
and all gears and bearings are greased properly.
NOTE: Grease the crankshaft and connecting rod
every 100 hours of use (grease fittings
supplied).