Titan 700-129, 700-134 User Manual

Page 1
Owner’s Manual
For professional use only
Do not use this equipment before reading this manual!
NOTE: This manual contains
540ix
Airless Sprayer
Model Numbers:
Skid Basic 700-129 High Rider Basic 700-134
Printed in the U. S. A.
X-Lock Theft Deterrent System
Security Code
— — — —
Serial # _ _ _ _ _ _ _ _ _ _
1206 © 2006 Titan Tool Inc. All rights reserved. Form No. 313-2704A
Page 2
Table of Contents
WARNING
CAUTION
WARNING
WARNING
Safety Precautions.................................................................2
Specifications .........................................................................3
General Description ...............................................................4
Operation ................................................................................4
Setup ....................................................................................4
Preparing to Paint.................................................................4
Painting.................................................................................5
Control Panel Indicators .......................................................5
Pressure Relief Procedure ...................................................6
Xact Digital Control System Operation.................................6
Spraying ..................................................................................8
Spraying Technique ..............................................................8
Practice.................................................................................8
Cleanup ...................................................................................9
Maintenance............................................................................9
General Repair and Service Notes.......................................9
Replacing the Motor ...........................................................10
Replacing the Gears...........................................................10
Replacing the Transducer...................................................11
Replacing the PRIME/SPRAY Valve...................................11
Servicing the Fluid Section.................................................12
Replacing the Filters...........................................................13
Troubleshooting ...................................................................14
Xact Digital Control System Error Messages .....................15
Parts Listings........................................................................20
Main Assembly....................................................................20
Skid Assembly ....................................................................21
Siphon Assembly ................................................................21
Fluid Section Assembly ......................................................22
Drive Assembly...................................................................23
High Rider Cart Assembly ..................................................24
Labels .................................................................................24
Electrical Schematic ...........................................................24
Accessories ........................................................................25
Warranty................................................................................28
Safety Precautions
This manual contains information that must be read and understood before using the equipment. When you come to an area that has one of the following symbols, pay particular attention and make certain to heed the safeguard.
This symbol indicates a potential hazard that may cause serious injury or loss of life. Important safety information will follow
This symbol indicates a potential hazard to you or to the equipment. Important information that tells how to prevent damage to the equipment or how to avoid causes of minor injuries will follow.
NOTE: Notes give important information which should
A. SAVE THESE INSTRUCTIONS – To reduce the risks of
B.
.
be given special attention.
IMPORTANT SAFETY INSTRUCTIONS
fire or explosion, electrical shock, and the injury to persons, read and understand all instructions included in this manual. Be familiar with the controls and the proper usage of the equipment.
WARNING – To reduce the risk of fire or explosion:
1. Do not spray flammable or combustible materials near an open flame, pilot lights or sources of ignition such as hot objects, cigarettes, motors, electrical equipment and electrical appliances. Avoid creating sparks from connecting and disconnecting power cords.
2. For units intended for use with only water-based materials — Do not spray or clean with flammable liquids. For use with water-based liquids only.
3. For units intended for use with only water-based or mineral spirit-type materials with a minimum flash point of 21ºC (69.8ºF) — Do not spray or clean with liquids having a flash point of less than 21ºC (69.8ºF). Flash point is the temperature at which a fluid can produce enough vapor to ignite.
4. Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use only conductive or grounded high-pressure airless paint sprayer hoses specified by the manufacturer.
5. Verify that all containers and collection systems are grounded to prevent static discharge.
6. Connect to a grounded outlet and use grounded extension cords. Do not use a 3 to 2 adapter.
7. Do not use a paint or solvent containing halogenated hydrocarbons. Such as chlorine, bleach mildewcide, methylene chloride and trichloroethane. They are not compatible with aluminum. Contact the coating supplier about compatibility of material with aluminum.
8. Keep spray area well ventilated. Keep a good supply of fresh air moving through the area to keep the air within the spray area free from accumulation of flammable vapors. Keep pump assembly in well ventilated area. Do not spray pump assembly.
9. Do not smoke in the spray area.
10. Do not operate light switches, engines, or similar spark producing products in the spray area.
11. Keep area clean and free of paint or solvent containers, rags, and other flammable materials.
12. Know the contents of the paint and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvent manufacture’s safety instructions.
13. Place pump at least 25 feet (7.62 meters) from the spray object in a well ventilated area (add more hose if necessary). Flammable vapors are often heavier than air. Floor area must be extremely well ventilated. The pump contains arcing parts that emit sparks and can ignite vapors.
14. Plastic can cause static sparks. Never hang plastic to enclose spray area. Do not use plastic drop cloths when spraying flammable material.
15. Fire extinguisher equipment shall be present and working.
C. WARNING – To reduce the risk of skin injection:
HAZARD: Injection injury – A high pressure fluid stream produced
by this equipment can pierce the skin and underlying tissues, leading to a serious injury and possible amputation. See a physician immediately. DO NOT TREAT AN INJECTION AS A SIMPLE CUT.
1. Do not aim the gun at, or spray any person or animal.
2. Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.
3.
Always use the nozzle tip guard. Do not spray without
the nozzle tip guard in place.
4. Only use a nozzle tip specified by the manufacturer.
2 © Titan Tool Inc. All rights reserved.
Page 3
5. Use caution when cleaning and changing nozzle tips.
WARNING
CAUTION
CAUTION
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
In the case where the nozzle tip clogs while spraying,
ALWAYS lock gun trigger, shut pump off, and release all
pressure before servicing, cleaning tip or guard, or changing tip. Pressure will not be released by turning off the motor. The PRIME/SPRAY valve handle must be turned to PRIME to relieve the pressure. Refer to PRESSURE RELIEF PROCEDURE described in the pump manual.
6. Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and relieve the pressure in accordance with the manufacturer’s instructions.
7. High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection occurs, seek medical attention immediately.
8. Check hoses and parts for signs of damage, a leak can inject material into the skin. Inspect hose before each use. Replace any damaged hoses or parts.
9. This system is capable of producing 3300 PSI / 23 MPa. Only use replacement parts or accessories that are specified by the manufacturer and that are rated a minimum of 3300 PSI. This includes spray tips, nozzle guards, guns, extensions, fittings, and hose.
10. Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
11. Verify that all connections are secure before operating the unit.
12. Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls. Pressure will not be released by turning off the motor. The PRIME/SPRAY valve handle must be turned to PRIME to relieve the pressure. Refer to PRESSURE RELIEF PROCEDURE described in the pump manual.
13. Always remove the spray tip before flushing or cleaning the system.
12. Before each use, check all hoses for cuts, leaks, abrasion or bulging of cover. Check for damage or movement of couplings. Immediately replace hose if any of those conditions exist. Never repair a paint hose. Replace with a conductive high-pressure hose.
13. Do not spray outdoors on windy days.
14. Always unplug cord from outlet before working on equipment.
Grounding Instructions
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER — Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary wire to either flat blade terminal. The wire with insulation having a green outer surface with or without yellow stripes is the grounding wire and must be connected to the grounding pin.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided. If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.
, do not connect the green grounding
D. WARNING – To reduce the risk of injury:
10. Follow all appropriate local, state and national codes
11. The United States Government Safety Standards have
1. Always wear appropriate gloves, eye protection, clothing and a respirator or mask when painting. Hazardous vapors – Paints, solvents, insecticides, and other materials can be harmful if inhaled or come in contact with body. Vapors can cause severe nausea, fainting or poisoning.
2. Do not operate or spray near children. Keep children away from equipment at all times.
3.
Do not overreach or stand on an unstable support.
Keep effective footing and balance at all times.
4. Stay alert and watch what you are doing.
5. Do not operate the unit when fatigued or under the influence of drugs or alcohol.
6. Do not kink or over-bend the hose. Airless hose can develop leaks from wear, kinking and abuse. A leak can inject material into the skin.
7. Do not expose the hose to temperatures or pressures in excess of those specified by manufacturer.
8. Do not use the hose as a strength member to pull or lift the equipment.
9. Use lowest possible pressure to flush equipment.
governing ventilation, fire prevention and operation.
been adopted under the Occupational Safety and Health Act (OSHA). These standards, particularly part 1910 of the General Standards and part 1926 of the Construction Standards should be consulted.
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the product. Make sure the extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current the product will draw voltage resulting in loss of power and overheating. A 12 gauge cord is recommended. If an extension cord is to be used outdoors, it must be marked with the suffix W-A after the cord type designation. For example, a designation of SJTW-A would indicate that the cord would be appropriate for outdoor use.
When the sprayer is used with a generator or uncontrolled line voltage, the use of Titan’s “Line Surge Protector” (P/N 800-935) is recommended.
. An undersized cord will cause a drop in line
Specifications
Gallons per minute (GPM)...............0.50 (1.9 LPM)
Maximum tip sizes ...........................0.022”
Maximum pressure ..........................3300 PSI (22.8 MPa)
Power...............................................1.15 HP Infinity Brushless
Weight, Skid.....................................30 lbs. (13.6 kg)
Weight, High Rider...........................55 lbs. (24.9 kg)
Maximum hose length......................300’ (91.4 m)
DC motor, 120 V, 60 Hz, 12 A
© Titan Tool Inc. All rights reserved. 3
Page 4
General Description
CAUTION
WARNING
WARNING
ON/OFF
Switch
Motor
Siphon
Tube
Xact Digital
Control System
(Optional)
Control System
Cover
Pressure
Control
Knob
Oil Cup
Outlet Fitting
Fluid Section
Return Hose
PRIME/ SPRAY Valve
Min PSI
(Bar)
Max PSI
(Bar)
Pulse
Clean
CAUTION
Min PSI
(Bar)
Max PSI
(Bar)
Blinking Yellow
0-200 PSI
Solid Yellow 201-1900 PSI
Solid Green
1901-3300 PSI
Motor Running
Pulse
Clean
Min. – 1900 PSI
(yellow zone)
1901 – 3300 PSI (green zone)
Turbo PulseClean
(red zone)
OFF
(black
zone)
Pressure Control Knob
CAUTION
CAUTION
This airless sprayer is a precision power tool used for spraying many types of materials. Read and follow this instruction manual carefully for proper operating instructions, maintenance, and safety information.
Operation
Always use a minimum 12 gauge, three-wire extension cord with a grounded plug. Never remove the third prong or use an adapter.
Preparing a New Sprayer
If this sprayer is new, it is shipped with test fluid in the fluid section to prevent corrosion during shipment and storage. This fluid must be thoroughly cleaned out of the system with mineral spirits before you begin spraying.
Always keep the trigger lock on the spray gun in the locked position while preparing the system.
Place the siphon tube into a container of mineral spirits
1. that has a flash point of 140ºF (60ºC) or above.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
This equipment produces a fluid stream at extremely high pressure. Read and understand the warnings in the Safety Precautions section at the front of this manual before operating this equipment.
Setup
Perform the following procedure before plugging in the power cord of an electric unit.
1. Ensure that the siphon tube and the return hose are attached and secure.
2. Using a wrench, attach a minimum of 50’ of 1/4” nylon airless spray hose to the outlet fitting on the sprayer. Tighten securely.
3. Attach an airless spray gun to the spray hose. Using two wrenches (one on the gun and one on the hose), tighten securely.
NOTE: Do not attach the tip to the spray gun yet.
Make sure all airless hoses and spray guns are electrically grounded and rated at or above the maximum operating pressure range of the airless sprayer
4. Make sure the pressure control knob is in its OFF position in the black zone.
5. Make sure the ON/OFF switch is in its OFF position.
6. Fill the oil cup with one tablespoon of piston seal lubricant (Piston Lube).
Never operate unit for more than ten seconds without fluid. Operating this unit without fluid will cause unnecessary wear to the packings.
7. Make sure the electrical service is 120V, 15 amp minimum.
8. Plug the power cord into a properly grounded outlet at least 25’ from the spray area.
Remove the tip if it is already attached.
.
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn on the sprayer by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the test fluid out through the return hose and into the waste container.
7. Turn off the sprayer by moving the ON/OFF switch to the OFF position.
Preparing to Paint
Before painting, it is important to make sure that the fluid in the system is compatible with the paint that is going to be used.
NOTE: Incompatible fluids and paint may cause the
Always keep the trigger lock on the spray gun in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
2. Place the return hose into a metal waste
3. Set the pressure to minimum by turning
4. Move the PRIME/SPRAY valve down to the
NOTE: Hold the return hose in the waste
4 © Titan Tool Inc. All rights reserved.
valves to become stuck closed, which would require disassembly and cleaning of the sprayer’s fluid section.
solvent for the material being sprayed (refer to recommendations of the material manufacturer).
An
example of an appropriate solvent is water for latex paint.
container.
the pressure control knob to the “Min” setting in the yellow zone.
PRIME position.
container when moving the PRIME/SPRAY valve to PRIME in case the sprayer is pressurized.
Page 5
5. Turn on the sprayer by moving the ON/OFF switch to the
Min PSI
(Bar)
Max PSI
(Bar)
Pulse
Clean
WARNING
Trigger lock in
locked position.
WARNING
Min PSI
(Bar)
Max PSI
(Bar)
Blinking Yellow
0-200 PSI
Solid Yellow
201-1900 PSI
Solid Green
1901-3300 PSI
Motor Running
Pulse
Clean
Pressure
Indicator
Motor Running
Indicator
WARNING
Trigger lock in
locked position.
WARNING
ON position.
6. Allow the sprayer to run for 15–30 seconds to flush the old solvent out through the return hose and into the metal waste container.
7. Turn off the sprayer by moving the ON/OFF switch to the OFF position.
NOTE: Make sure that the spray gun does not have a
tip or tip guard installed.
8. Move the PRIME/SPRAY valve up to the SPRAY position.
9. Turn on the sprayer.
10. Unlock the gun by turning the gun trigger lock to the unlocked position.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
12.
Trigger the gun into the metal waste container until all air and solvent is flushed from the spray hose and paint is flowing freely. from the gun.
13. Lock the gun by turning the gun trigger lock to the locked position.
14. Turn off the sprayer.
15. Attach tip guard and tip to the gun as instructed by the tip guard or tip manuals.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
11. Trigger the gun into the metal waste container until the old solvent is gone and fresh solvent is coming out of the gun.
12.
Lock the gun by turning the gun trigger lock to the locked position.
13. Set down the gun and increase the pressure by turning the pressure control knob slowly clockwise into the green zone.
14. Check the entire system for leaks. If leaks occur, follow the “Pressure Relief Procedure” in this manual before tightening any fittings or hoses.
15. Follow the “Pressure Relief Procedure” in this manual before changing from solvent to paint.
Be sure to follow the pressure relief procedure when shutting the unit down for any purpose, including servicing or adjusting any part of the spray system, changing or cleaning spray tips, or preparing for cleanup.
Painting
1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
4. Move the PRIME/SPRAY valve down to the PRIME position.
5. Turn on the sprayer by moving the ON/OFF switch to the ON position.
6. Allow the sprayer to run until paint is coming through the return hose into the metal waste container.
7. Turn off the sprayer by moving the ON/OFF switch to the OFF position.
8. Remove the return hose from the waste container and place it in its operating position above the container of paint.
9. Move the PRIME/SPRAY valve up to the SPRAY position.
10. Turn on the sprayer.
11. Unlock the gun by turning the gun trigger lock to the unlocked position.
© Titan Tool Inc. All rights reserved. 5
POSSIBLE INJECTION HAZARD. Do not spray without the tip guard in place. Never trigger the gun unless the tip is in either the spray or the unclog position.
Always engage the
gun trigger lock before removing, replacing or cleaning tip.
16. Turn on the sprayer.
17. Increase the pressure by turning the pressure control knob slowly clockwise toward the green zone and test the spray pattern on a piece of cardboard. Adjust the pressure control knob until the spray from the gun is completely atomized. Try to keep the pressure control knob at the lowest setting that maintains good atomization.
NOTE: Turning the pressure up higher then needed to
atomize the paint will cause premature tip wear and additional overspray.
NOTE: If the sprayer is equipped with an Xact Digital
Control System, go to “Xact Digital Control System Operation” at the end of the Operation section of this Manual.
Control Panel Indicators
The following is a description of the control panel indicators.
Pressure Indicator
The pressure indicator shows the current operating pressure of the sprayer. It has three different indications: blinking yellow, solid yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is operating between 0 and 200 PSI. indicator means:
• The sprayer is plugged in and turned “ON”
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher pressure and the PRIME/SPRAY valve is in the SPRAY position, either the spray tip is worn or the sprayer is in need of service/repair.
A blinking yellow pressure
Page 6
Solid Yellow
Trigger lock in
locked position.
WARNING
PRE-SET #1 750 PRESS +/- TO CHG
PSI SETTING 750 SELECT-4 CHG-2
SELECT
PRE-SETS 1-4
USER PRE-SETS
SELECT-4 MENU-1
SET PSI 3000 ACTUAL PSI 2950
SET PSI 3000 ACTUAL PSI 2950
MENU + SELECT
4321
Display
Function
Keys
When the pressure indicator is solid yellow, the sprayer is operating between 201 and 1900 PSI. indicator means:
• The sprayer is at the proper pressure setting for spraying stain, lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the pressure is set so that it starts at solid green, it indicates one of the following:
a. Tip Wear Indicator — when spraying with latex or at
high pressure the solid yellow appears. This means the tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the
sprayer is put in the gun, the pressure indicator will turn from solid green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure
indicator appears when using a new tip and the pressure is set at maximum, service may be required (worn packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oil-based and latex house paints
• The sprayer is operating at peak performance at a high pressure setting
Motor Running Indicator
The Motor Running indicator is on when the motor is commanded to run. This indicator is used by service centers to troubleshoot motor problems.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure when shutting the unit down for any purpose, including servicing or adjusting any part of the spray system, changing or cleaning spray tips, or preparing for cleanup.
1. Lock the gun by turning the gun trigger lock to the locked position.
2. Turn of
3. Turn the pressure control knob
4. Unlock the gun by turning the gun trigger
5. Hold the metal part of the gun firmly to
6. Trigger the gun to remove any pressure
7. Lock the gun by turning the gun trigger
8. Move the PRIME/SPRAY valve down to
f the sprayer by moving the
ON/OFF switch to the OFF position.
counterclockwise to its OFF position in the black zone.
lock to the unlocked position.
the side of a metal container to ground the gun and avoid a build up of static electricity.
that may still be in the hose.
lock to the locked position.
the PRIME position.
A solid yellow pressure
Xact Digital Control System Operation (if equipped)
The Xact Digital Control System is an optional add-on that increases the functionality of the sprayer. It is installed directly below the pressure control knob on the control panel. It consists of a display and four function keys. The display shows various menu screens that allow the user to customize and monitor sprayer operation using the function keys.
NOTE: The pressure control knob overrides the Xact
Function Keys
The function keys are numbered 1–4. Each key is labeled with an additional function as well.
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens or performs a function described on the active menu screen.
#2/+ Key
Pressing the #2 key performs a function described on the active menu screen or increases a value.
#3/- Key
Pressing the #3 key performs a function described on the active menu screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs a function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize and monitor sprayer operation. They include Main Screen, User Pre-Sets, Volume Pumped, Job Volume, Unit Serial #, TImers, Job Timers, Service Time, Pressure, Security Code, Prime, and Pulse Clean.
Main Screen
The Main Screen is the default screen for the control system at sprayer startup. Pressing the #2 key switches between PSI and MPa units of measure. Press the #1 key to scroll through the remaining menu screens.
User Pre-Sets Screen
The User Pre-Sets screen allows the user to set four dif
ferent pressure settings and save them for future use. To
select the User Pre-Sets screen, press the #4 key. Press keys 1 through 4 from
the Select screen to select or change a pre-set pressure.
Press the #4 key to select the setting and the Main Screen will appear.
Press the #2 key to change the setting. On the following screen, use the #2/+ key to increase the setting or the #3/- screen to decrease the setting. Once the desired setting has been reached, press the #4 key to set and the Main Screen will appear. To select or change the remaining three pre-sets, scroll to the User Pre-Sets screen and repeat the above procedure.
6 © Titan Tool Inc. All rights reserved.
Digital Control System settings. Anytime the pressure control knob is turned, the sprayer pressure will change accordingly.
Page 7
Volume Pumped Screen
SET PSI 3000 ACTUAL PSI 2950
PRESSURE
SELECT-4 MENU-1
SERVICE @ XXXHR RUN HOURS XX
SERVICE TIME
SELECT-4 MENU-1
ON TIME XXXXX:XX RUN TIME XXXX:XX
JOB TIMERS
SELECT-4 MENU-1
ON TIME XXXXX:XX RUN TIME XXXX:XX
TIMERS
SELECT-4 MENU-1
SER # XXXXXXXXXX PRESS 1 FOR MENU
UNIT SERIAL #
SELECT-4 MENU-1
JOB GALLONS XXXX MENU-1 RESET-3
JOB VOLUME
SELECT-4 MENU-1
GALLONS XXXXXX PRESS 1 FOR MENU
VOLUME PUMPED
SELECT-4 MENU-1
PULSE CLEAN
ACTUAL PSI XXXX
PRIME
ENTER NEW CODE
NUMBER
ENTER OLD CODE
NUMBER
SECURITY CODE
SELECT-4 MENU-1
The Volume Pumped screen shows the total number of gallons or liters sprayed by the sprayer
.
To select the Volume Pumped screen, press the #4 key.
Job Volume Screen
The Job Volume screen allows the user to reset a gallon counter to track usage on specific jobs.
To select the Job V screen, press the #4 key.
Unit Serial # Screen
The Unit Serial # screen shows the sprayers serial number
.
To select the Unit Serial # screen, press the #4 key.
Timers Screen
The Timers screen shows the total time the sprayer has been turned on as well as the total time the sprayer has been running (pumping).
T
o select the Timers screen,
press the #4 key.
Job Timers Screen
The Job Timers screen allows the user to reset the “ON TIME” and “RUN TIME” to track time on specific jobs.
T
o select the Job TImers screen, press the #4 key. The screen will toggle between the timers and a screen that allows the user to reset the timers.
Service Time Screen
The Service Time screen allows the user to set a service time interval (in hours). Below the set time, the screens shows the current amount of hours on the sprayer. T #4 key.
The screen will toggle between the service hours and a screen that allows the user to change the service time interval.
When the service time interval is set and met by the run hours, the display will toggle between the "Main screen" and a "Service Required" screen at sprayer startup. To stop the toggling, scroll to the "Service Time" screen and either set a new service time interval or set the service time to "0".
Pressure Screen
The Pressure screen allows the user to see the current set point pressure as well as the actual working pressure.
T
o select the Pressure screen, press the #4 key. This screen is also the Main Screen.
olume
o select the Service TImer screen, press the
Security Code Screen
The Security Code screen allows the user to set a four digit security code to prevent unauthorized use of the sprayer set, the control system display will ask for the code at startup. If the correct code is entered, the display will show the Main Screen and the sprayer will operate. If the wrong code is entered, the display will continue to ask for the correct code and the sprayer will be disabled. To set or change the security code, press the #2 key.
NOTE: If the sprayer is new, no security code is set
Enter the old security code number to access the screen that allows the code change. If the wrong code is entered, the display will continue to ask for the correct code and the security code cannot be changed.
Enter the new security code. Once the new code is entered, the display will automatically ask that the new code be re-entered for verification. If the same new code is re-entered, the display will confirm that the new code has been accepted and return to the Main Screen. If the new code is re-entered incorrectly, the display will return to the “Enter New Code Number” screen and the process will repeat.
NOTE: To inactivate the X-Lock security function,
Prime Screen
The Prime screen appears when the pressure control knob is set at the “Min” setting in the yellow zone.
Pulse Clean Screen
The Pulse Clean screen appears when the pressure control knob is set at the PULSE CLEAN position in the red zone and the PRIME/SPRA
NOTE: If there is no action at any menu screen for 30
and the Main Screen will appear at startup. Also, when setting a security code for the first time, the “Enter Old Code Number” screen will not appear.
enter “1111” at the “Enter New Code Number” screen (this is the default code that leaves the sprayer unlocked). As a result, the Main Screen will appear at sprayer startup.
Y valve is in the PRIME position.
seconds, the display will go back to the Main Screen.
. If a security code has been
© Titan Tool Inc. All rights reserved. 7
Page 8
Spraying
Too Thick
Offspray
Arcing Gun at angle
start
stroke
release
trigger
pull trigger
end stroke
WARNING
Good spray pattern
Paint tailing pattern
Overlap edges
1st 2nd 3rd 4th 5th
POSSIBLE INJECTION HAZARD. Do not spray without the tip guard in place. Never trigger the gun unless the tip is in either the spray or the unclog position. Always engage the gun trigger lock before removing, replacing, or cleaning tip.
Spraying Technique
The following techniques, if followed, will assure professional painting results.
Hold the gun perpendicular to the surface and always at equal distance from the surface. Depending on the type of material, surface, or desired spray pattern, the gun should be held at a distance of 12 to 14 inches (30 to 35 cm).
Move the gun either across or up and down the surface at a steady rate. Moving the gun at a consistent speed conserves material and provides even coverage. The correct spraying speed allows a full, wet coat of paint to be applied without runs or sags.
Holding the gun closer to the surface deposits more paint on the surface and produces a narrower spray pattern. Holding the gun farther from the surface produces a thinner coat and wider spray pattern. If runs, sags, or excessive paint occur, change to a spray tip with a smaller orifice. If there is an insufficient amount of paint on the surface or you desire to spray faster, a larger orifice tip should be selected.
Maintain uniform spray stroke action. Spray alternately from left to right and right to left. Begin movement of the gun before the trigger is pulled.
Avoid arcing or holding the gun at an angle. This will result in an uneven finish.
Proper lapping (overlap of spray pattern) is essential to an even finish. Lap each stroke. If you are spraying horizontally, aim at the bottom edge of the preceding stroke, so as to lap the previous pattern by 50%.
For corners and edges, split the center of the spray pattern on the corner or edge and spray vertically so that both adjoining sections receive approximately even amounts of paint.
When spraying with a shield, hold it firmly against the surface. Angle the spray gun slightly away from the shield and toward the surface. This will prevent paint from being forced underneath.
Shrubs next to houses should be tied back and covered with a canvas cloth. The cloth should be removed as soon as possible. Titan gun extensions are extremely helpful in these situations.
Nearby objects such as automobiles, outdoor furniture, etc. should be moved or covered whenever in the vicinity of a spray job. Be careful of any other surrounding objects that could be damaged by overspray.
Practice
1. Be sure that the paint hose is free of kinks and clear of objects with sharp cutting edges.
2. Set the pressure to minimum by turning the pressure control knob to the “Min” setting in the yellow zone.
3. Move the PRIME/SPRAY valve up to its SPRAY position.
4. Turn the pressure control knob clockwise to its highest setting. The paint hose should stiffen as paint begins to flow through it.
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to check the spray pattern.
8. Use the lowest pressure setting necessary to get a good spray pattern. If the pressure is set too high, the spray pattern will be too light. If the pressure is set too low, tailing will appear or the paint will spatter out in gobs rather than in a fine spray.
8 © Titan Tool Inc. All rights reserved.
Page 9
Cleanup
WARNING
Min PSI
(Bar)
Max PSI
(Bar)
Pulse
Clean
WARNING
CAUTION
WARNING
CAUTION
WARNING
CAUTION
Special cleanup instructions for use with flammable solvents:
• Always flush spray gun preferably outside and at least one hose length from spray pump.
If collecting flushed solvents in a one gallon metal
• container, place it into an empty five gallon container, then flush solvents.
• Area must be free of flammable vapors.
• Follow all cleanup instructions.
13. Continue to trigger the spray gun into the waste container until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
mineral sprits through the entire system. For short-term storage when using latex paint,
pump water mixed with Titan Liquid Shield through the entire system (see the Accessories section of this manual for part number).
14. Follow the “Pressure Relief Procedure” found in the Operation section of this manual.
15. Unplug the unit and store in a clean, dry area.
Do not store the unit under pressure.
The sprayer, hose, and gun should be cleaned thoroughly after daily use. Failure to do so permits material to build up, seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun nozzle tip removed when using mineral spirits or any other solvent to clean the sprayer buildup may result in a fire or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the Operation section of this manual.
Remove the gun tip and tip guard and clean with a brush
2. using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate solvent (refer to recommendations of the material manufacturer). An example of the appropriate solvent is water for latex paint.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to its PRIME position.
NOTE: Hold the return hose in the waste
6. Set the pressure to Turbo PulseClean by
7. Turn on the sprayer by moving the
8. Allow the solvent to circulate through the unit and flush
9. Turn off the sprayer by moving the ON/OFF switch to the
10. Move the PRIME/SPRAY valve up to its
11. Turn on the sprayer.
Ground the gun by holding it against the edge of the metal container while flushing. Failure to do so may lead to a static electric discharge, which may cause a fire.
12. Trigger the gun into the metal waste
container when moving the PRIME/SPRAY valve to PRIME in case the sprayer is pressurized.
turning the pressure control knob to its PULSE CLEAN position in the red zone.
ON/OFF switch to the ON position.
the paint out of the return hose into the metal waste container.
OFF position.
SPRAY position.
container until the paint is flushed out of the hose and solvent is coming out of the gun.
, hose, or gun. Static electricity
Maintenance
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. Additionally, follow all other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver 3/8" Hex Wrench Needle Nose Pliers 5/16" Hex Wrench Adjustable Wrench 1/4" Hex Wrench Rubber Mallet 3/16" Hex Wrench Flat-blade Screwdriver 5/32” Hex Wrench
1. Before repairing any part of the sprayer, read the instructions carefully, including all warnings.
Never pull on a wire to disconnect it. Pulling on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be sure that the problem is corrected. If the sprayer does not operate properly determine if everything was done correctly. Refer to the Troubleshooting Charts to help identify other possible problems.
3. Make certain that the service area is well ventilated in case solvents are used during cleaning. Always wear protective eyewear while servicing. Additional protective equipment may be required depending on the type of cleaning solvent. Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your TITAN Airless Sprayer, call TITAN:
Customer Service (U.S.) .......................1-800-526-5362
Fax ................................................1-800-528-4826
Customer Service (Canada)..................1-800-565-8665
Fax ................................................ 1-905-856-8496
Customer Service (International)...........1-201-337-1240
Fax ................................................1-201-405-7449
, review the repair procedure to
© Titan Tool Inc. All rights reserved. 9
Page 10
Replacing the Motor
Motor
Motor Mounting Screw
Pump Housing
Front Cover
Front Cover Screw
Control Panel
Control Panel Mounting Screw
Motor Cover Screw
Motor Cover
Electronic
Pressure
Control
(EPC)
2nd Stage Gear
Thrust Washer
Gear and Crank Assembly
Armature Gear
Motor
Electronic
Pressure
Control
(EPC)
Motor
Mounting
Screw
Pump Housing
Front Cover
Front Cover Screw
Control Panel
Control Panel Mounting Screw
1. Perform the Pressure Relief Procedure and unplug the sprayer.
2. Loosen and remove the four motor cover screws. Remove the motor cover.
3. At the electronic pressure control (EPC) on the back of the motor, disconnect the wire coming from the potentiometer and the wire coming from the transducer. Also, disconnect the two wires coming from the control panel board (refer to the electrical schematic in the Parts List section of this manual).
4. Remove the four control panel mounting screws. Pull back the control panel for access to the control panel board.
5. At the the control panel board, disconnect the two wires coming from the motor (refer to the electrical schematic in the Parts List section of this manual).
6. Loosen and remove the four motor mounting screws.
7. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the front of the motor crankshaft that extends through the slider assembly.
8. With the motor removed, inspect the gears in the pump housing for damage or excessive wear. Replace the gears, if necessary.
9. Install the new motor into the pump housing.
10. Secure the motor with the four motor mounting screws.
11. Reconnect the wires (refer to the electrical schematic in the Parts List section of this manual).
12. Position the control panel on the pump housing and secure in position using the four control panel mounting screws.
13. Slide the motor cover over the motor. Secure the motor cover with the four motor cover screws.
Replacing the Gears
1. Perform the Pressure Relief Procedure and unplug the sprayer.
2. Loosen and remove the four motor cover screws. Remove the motor cover.
3. At the electronic pressure control (EPC) on the back of the motor, disconnect the wire coming from the potentiometer and the wire coming from the transducer. Also, disconnect the two wires coming from the control panel board (refer to the electrical schematic in the Parts List section of this manual).
4. Remove the four control panel mounting screws. Pull back the control panel for access to the control panel board.
5. At the the control panel board, disconnect the two wires coming from the motor (refer to the electrical schematic in the Parts List section of this manual).
6. Loosen and remove the four motor mounting screws.
7. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the front of the motor crankshaft that extends through the slider assembly.
8. Inspect the armature gear on the end of the motor for damage or excessive wear. If this gear is completely worn out, replace the entire motor.
9. Remove and inspect the 2nd stage gear for damage or excessive wear. Replace if necessary.
10. Remove and inspect the gear and crank assembly for damage or excessive wear. Replace if necessary.
11. Reassemble the pump by reversing the above steps. During reassembly, make sure the thrust washer is in place.
NOTE: Refill the gear box in the pump housing with
five ounces of Lubriplate (P/N 314-171).
10 © Titan Tool Inc. All rights reserved.
Page 11
Replacing the Transducer
T-Slot
Pump Housing
Pump Block
Pump Block Mounting Screw
Front
Cover
Front
Cover
Screw
Transducer
Assembly
WARNING
Gasket
Cam Base
Valve Stem
Pump Block
Valve Housing
Assembly
Valve Handle
Groove Pin
1. Loosen and remove the four front cover screws. Remove the front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the sprayer.
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
4. Tilt the pump back for easy access to the fluid section.
5.
Using a 3/8” hex wrench, loosen and remove the two pump block mounting screws.
6. Pull the pump block down approximately 1/2” from the pump housing to clear the transducer.
7. Slide the pump block and piston rod forward until the piston rod is out of the T-slot on the slider assembly.
8. Carefully pull the transducer wire out of the pump housing until the connection to the transducer jumper is exposed. Unplug the wire from the transducer jumper (refer to the electrical schematic in the Parts List section of this manual).
9. Using a wrench, remove the transducer assembly from the pump block.
10. Thread the new transducer assembly into the pump block. Tighten securely with a wrench.
11. Plug the new transducer wire into the transducer jumper (refer to the electrical schematic in the Parts List section of this manual).
12. Reassemble the pump by reversing steps 1–7.
Additionally, follow all
Replacing the PRIME/SPRAY Valve
Perform the following procedure using PRIME/SPRAY valve replacement kit P/N 700-258
1. Push the groove pin out of the valve handle.
2. Remove the valve handle and the cam base.
3. Using a wrench, loosen and remove the valve housing assembly.
4. Make sure the gasket is in place and thread the new valve housing assembly into the pump block. Tighten securely with wrench.
5. Place the cam base over the valve housing assembly. Lubricate the cam base with grease and line up the cam with the pump block.
6. Line up the hole on the valve stem with the hole in the valve handle.
7. Insert the groove pin into the valve handle and through the valve stem to secure the valve handle in position.
© Titan Tool Inc. All rights reserved. 11
Page 12
Servicing the Fluid Section
WARNING
CAUTION
Install upper packing
with raised lip and O-ring
facing down.
O-Ring
Raised Lip
Beveled Edge
Install lower packing
with the beveled
edge facing up.
Slider Assembly
Retainer Nut
Piston Guide
Upper Packing
Pump Block
Lower Packing
Pump Block Mounting Screw
Piston Rod
T-Slot
Use the following procedures to service the valves and repack the fluid section. Perform the following steps before performing any maintenance on the fluid section.
1. Loosen and remove the four front cover screws. Remove the front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the sprayer.
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. Additionally other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
4. For High Rider cart units, remove the return hose from the hose clip on the siphon tube. Unscrew the siphon tube from the foot valve housing.
5. For Skid units, unscrew the return hose assembly from the pump block. Remove the retaining clip from the bottom of the foot valve housing. Remove the siphon assembly
6. Tilt the sprayer back for easy access to the fluid section.
Servicing the Valves
The design of the fluid section allows access to the foot valve and seat as well as the outlet valve and seat without completely disassembling the fluid section. It is possible that the valves may not seat properly because of debris stuck in the foot valve seat or outlet valve seat. Use the following instructions to clean the valves and reverse or replace the seats.
1. Using a wrench, loosen and remove the foot valve housing from the pump block.
2. Clean out any debris in the foot valve housing and examine the valve housing and seat. If the seat is damaged, reverse or replace the seat.
3. Using a 5/16" hex wrench, loosen and remove the outlet valve retainer from the piston rod.
NOTE: Always service the
4. Clean out any debris and examine the outlet valve housing and seat. If the seat is damaged, reverse or replace the seat.
5. Remove, clean, and inspect the outlet cage, crush washer, and outlet valve ball. Replace if they are worn or damaged.
NOTE: The outlet cage always must be used with the
, follow all
.
Pump Block Bushing Foot Valve
Seal Inlet Cage Foot Valve
Ball Foot Valve
Seat PTFE
O-Ring Foot Valve
Housing
Piston Rod
outlet valve with the piston rod attached to the pump. This will prevent the piston rod from rotating during disassembly of the outlet valve.
crush washer. They are included together in the repacking kit as assembly P/N 704-642.
Outlet Cage Crush
Washer Outlet Valve
Ball Outlet Valve
Seat Outlet Valve
Retainer
6. Reassemble the valves by reversing the steps above.
NOTE: During reassembly of the outlet valve, apply
one drop of Loctite (included in the repacking kit) to the threads of the outlet valve retainer before threading it into the piston rod. Then, torque the retainer to 144 in./lbs. (12 ft./lbs.).
Repacking the Fluid Section
1. Remove the foot valve assembly using the steps in the “Servicing the Valves” procedure above.
NOTE: The outlet valve does not need to be
2. Using a 3/8” hex
3. Pull the pump block
4. Slide the pump block
5. Slide the piston rod
6. Loosen and remove
7. Remove the upper
8. Clean the pump block
9. Inspect the piston rod for wear and replace if necessary.
10. Reassemble the outlet valve assembly into the piston rod.
NOTE: Use the T-slot on the slider assembly to hold
Never use a wrench on the piston itself. This could cause damage to the piston and cause leakage.
11. Insert the piston guide into the retainer nut. Thread the
12.
12 © Titan Tool Inc. All rights reserved.
disassembled from the piston rod for this procedure.
wrench, loosen and remove the two pump block mounting screws.
down approximately 1/2” from the pump housing.
and piston rod forward until the piston rod is out of the T-slot on the slider assembly.
out through the bottom of the pump block
the retainer nut and piston guide from the pump block.
and lower packings from the pump block.
and install the new upper and lower packings. Refer to the illustration below for proper packing orientation.
Tighten the outlet valve retainer with a wrench until secure.
the piston rod in position while securing the outlet valve retainer.
retainer nut into the pump block until it is hand tight. Slide the piston guide tool (included in the repacking kit)
over the top of the piston rod and insert the piston rod through the bottom of the pump block. Using a rubber mallet, tap the bottom of the piston rod lightly until the piston rod is in position in the pump block.
Page 13
Pump Block
Seal
Filter
Filter Housing
NOTE: Coat the piston guide tool and the piston rod
Handle
Handle Seal
Filter
Gun Body
with grease before inserting them into the pump block.
13. Using a wrench, tighten the retainer nut securely.
14. Slide the top of the piston rod into the T-slot on the slider assembly.
15. Position the pump block underneath the pump housing and push up until it rests against the pump housing.
16. Thread the pump block mounting screws through the pump block and into the pump housing. Tighten securely.
17. Reassemble the foot valve assembly into the pump block.
18. For High Rider cart units, thread the siphon tube into the foot valve and tighten securely. Make sure to wrap the threads on the siphon tube with PTFE tape before assembly. Replace the return hose into the hose clip on the siphon tube.
19. For Skid units, insert the elbow on the siphon assembly into the bottom of the foot valve housing. Push the retaining clip up into the groove inside the foot valve housing to secure the siphon assembly in position. Thread the return hose into the pump block and tighten securely.
20. Place the front cover on the pump housing and secure in position using the four front cover screws.
21. Turn on the sprayer by following the procedure in the “Operation” section of this manual and check for leaks.
NOTE: Repacking kit P/N 704-586 is available. For
best results use all parts supplied in this kit.
Replacing the Filters
Pump Filter
1. Loosen and remove the filter housing.
2. Turning clockwise, unscrew the filter from the pump block.
NOTE: Left-handed threads require turning the filter
clockwise to remove. If the filter breaks off in the pump block, use a small wood screw to remove.
3. Inspect the seal. Based on inspection, clean or replace the seal.
4. Turning counterclockwise, thread the new or cleaned filter into the pump block.
5. Slide the filter housing over the filter and thread it into the pump block until secure.
Gun Filter
1. Move the gun trigger lock to the unlocked position.
2. Loosen and remove the handle from the gun body.
3. Turning clockwise, unscrew the filter from the gun body.
NOTE: Left-handed threads require turning the filter
4. Turning counterclockwise, screw the new or cleaned filter
5. Make sure the handle seal is in position and thread the
6. Move the gun trigger lock to the locked position.
NOTE: For more detail, part number information, and
clockwise to remove.
into the gun body.
handle into the gun body until secure.
complete assembly drawings, please see the
II
LX-80 Manual (P/N 313-2293).
Professional Airless Gun Owner's
© Titan Tool Inc. All rights reserved. 13
Page 14
Problem
The unit will not run.
Troubleshooting
Cause
1. The unit is not plugged in.
2. Tripped breaker.
3. The pressure is set too low (pressure control knob set at minimum setting does not supply power to unit).
4. Faulty or loose wiring.
5. Excessive motor temperature.
6. ON/OFF switch is defective.
Solution
1. Plug the unit in.
2. Reset the breaker.
3. Turn the pressure control knob clockwise to supply power to the unit and increase the pressure setting.
4. Inspect or take to a Titan authorized service center.
5. Allow motor to cool.
6. Replace the ON/OFF switch.
The unit will not prime.
The unit will not build or maintain pressure.
1. The PRIME/SPRAY valve is in the SPRAY position.
2. Air leak in the siphon tube/suction set.
3. The pump filter and/or inlet screen is clogged.
4. The siphon tube/suction set is clogged.
1. The spray tip is worn.
2. The spray tip is too large.
3. The pressure control knob is not set properly.
4. The pump filter, gun filter, or inlet screen is clogged.
5. Material flows from the return hose when the PRIME/SPRAY valve is in the SPRAY position.
6. Air leak in the siphon tube/suction set.
7. There is external fluid leak.
8. There is an internal fluid section leak (packings are worn and/or dirty, valve balls are worn).
9. Worn valve seats
10. Motor powers but fails to rotate
1. Rotate the PRIME/SPRAY valve clockwise to the PRIME position.
2. Check the siphon tube/suction set connection and tighten or re-tape the connection with PTFE tape.
3. Remove the pump filter element and clean. Remove the inlet screen and clean.
4. Remove the siphon tube/suction set and clean.
1. Replace the spray tip following the instructions that came with the spray gun.
2. Replace the spray tip with a tip that has a smaller orifice following the instructions that came with the spray gun.
3. Turn the pressure control knob clockwise to increase the pressure setting.
4. Remove the pump filter element and clean. Remove the gun filter and clean. Remove the inlet screen and clean.
5. Clean or replace the PRIME/SPRAY valve.
6. Check the siphon tube/suction set connection and tighten or re-tape the connection with PTFE tape.
7. Check for external leaks at all connections. Tighten connections, if necessary.
8. Clean the valves and service the fluid section following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
9. Reverse or replace the valve seats following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
10. Take unit to a Titan authorized service center.
Fluid leakage at the upper end of the fluid section.
Excessive surge at the spray gun.
1. The upper packing is worn.
2. The piston rod is worn.
1. Wrong type of airless spray hose.
2. The spray tip worn or too large.
3. Excessive pressure.
14 © Titan Tool Inc. All rights reserved.
1. Repack the pump following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
2. Replace the piston rod following the “Servicing the Fluid Section” procedure in the Maintenance section of this manual.
1. Replace hose with a minimum of 50’ of 1/4” grounded textile braid airless paint spray hose.
2. Replace the spray tip following the instructions that came with the spray gun.
3. Rotate the pressure control knob counterclockwise to decrease spray pressure.
Page 15
Problem
HIGH MOTOR
TEMPERATURE
LOW VOLTAGE
CHECK MOTOR
CHECK TRANSDUCER
CHECK PAINT
WARNING
COMMUNICATION
ERROR
EXCEEDED
PRESSURE LIMIT
HIGH LOAD
CHECK MECHANISM
HIGH CONTROL
TEMPERATURE
Poor spray pattern.
Troubleshooting
Cause
1. The spray tip is too large for the material being used.
2. Incorrect pressure setting.
3. Insufficient fluid delivery.
4. The material being sprayed is too viscous.
Solution
1. Replace the spray tip with a new or smaller spray tip following the instructions that came with the spray gun.
2. Rotate the pressure control knob to adjust the pressure for a proper spray pattern.
3. Clean all screens and filters.
4. Add solvent to the material according to the manufacturer's recommendations.
The unit lacks power.
1. The pressure adjustment is too low.
2. Improper voltage supply.
Xact Digital Control System Error Messages (if equipped)
The following error message screens appear whenever the Xact Digital Control System detects a problem with the sprayer. Once a problem occurs and the error message appears, the sprayer will shut down.
Before proceeding, follow the Pressure Relief Procedure outlined previously in this manual. other warnings to reduce the risk of an injection injury, injury from moving parts or electric shock. Always unplug the sprayer before servicing!
Check Paint Screen (E1)
The Check Paint screen appears when the pump pressure drops to a very low level and the pressure control knob has not been adjusted. Check the paint level and refill. Restart the sprayer by following the “Painting” procedure in the Operation section of this manual.
Check Transducer Screen (E2)
The Check Transducer screen appears when the transducer has become disconnected or is defective. center for repair.
Check Motor Screen (E3)
The Check Motor screen appears when the motor or motor sensor is defective. Take the sprayer to a Titan authorized service center for repair
Low Voltage Screen (E4)
The Low Voltage screen appears when the sprayer shuts down because of low input voltage. Check the power supply and correct the problem. Restart the sprayer by following the “Painting” procedure in the Operation section of this manual.
High Motor Temperature Screen (E5)
The High Motor Temperature screen appears when the temperature of the motor has risen too high. Take the sprayer to a center for repair.
Take the sprayer to a Titan authorized service
Additionally, follow all
Titan authorized service
1. Rotate the pressure control knob clockwise to increase the pressure setting.
2. Reconnect the input voltage for 120V AC.
High Control Temperature Screen (E6)
The High Control Temperature screen appears when the temperature of the Xact Digital Control System has risen too high. authorized service center for repair.
High Load Check Mechanism Screen (E7)
The High Load Check Mechanism screen appears when the sprayer shuts down because of high current or when the sprayer goes into current fold back mode.. service center for repair.
Exceeded Pressure Limit Screen (E8)
The Exceeded Pressure Limit screen appears when the sprayer pressure exceeds 3300 PSI / 22.8 MPa. Take the sprayer to a service center for repair.
Communication Error Screen (E9)
The Communication Error screen appears when the Xact Digital Control System loses communication with the control panel. Titan authorized service center for repair.
.
Take the sprayer to a Titan authorized
Take the sprayer to a Titan
Titan authorized
Take the sprayer to a
© Titan Tool Inc. All rights reserved. 15
Page 16
Consignes de sécurité
AVERTISSEMENT
ATTENTION
AVERTISSEMENT
AVERTISSEMENT
Le présent manuel comprend des renseignements devant être lus attentivement avant toute utilisation de l'appareil. Lorsque l'un des symboles suivants apparaît, il est recommandé d'être particulièrement attentif et de tenir compte des mesures de sécurité indiquées.
Ce symbole indique un danger potentiel pouvant causer des blessures graves ou même mortelles. Des renseignements importants sur la sécurité sont également indiqués.
Ce symbole indique un danger potentiel pouvant causer des blessures corporelles ou des dommages à l'équipement. Des renseignements importants sur la façon de prévenir tout dommage à l'équipement ou toute blessure corporelle mineure sont également indiqués.
NOTA : Les remarques donnent des renseignements
A.
B. AVERTISSEMENT – Pour réduire le risque d’incendie
importants requérant une attention particulière.
CONSIGNES DE SÉCURITÉ IMPORTANTES
CONSERVEZ CES CONSIGNES – Pour réduire les risques d’incendie ou d’explosion, d’électrocution et de blessures, lisez et assurez-vous de bien comprendre toutes les consignes contenues dans ce manuel. Familiarisez-vous avec les commandes et l’usage correct de l’équipement.
ou d’explosion :
1. Ne pulvérisez pas de matières inflammables ou combustibles près d’une flamme nue, de voyants lumineux ou de sources d’ignition telles que des objets chauds, cigarettes, moteurs, matériel et appareils électriques. Évitez de produire des étincelles en connectant et en déconnectant les cordons électriques.
2. Pour les appareils destinés à n’utiliser que des produits à l’eau – Ne pulvérisez pas et ne les nettoyez pas avec des liquides inflammables. Exclusivement pour usage avec liquides à base d’eau.
3. Pour les appareils destinés à un usage exclusif avec des produits à l’eau ou des produits minéraux de type alcool avec un point d’éclair minimum de 21 ºC (70 ºF) – Ne pulvérisez pas et ne les nettoyez pas avec des liquides ayant un point d’éclair inférieur à 21 ºC (70 ºF). Le point d’éclair est la température à laquelle un fluide peut produire suffisamment de vapeur pour s’enflammer.
4. L’écoulement de peinture ou de solvant dans l’équipement peut produire de l’électricité statique. L’électricité statique crée un risque d’incendie ou d’explosion en présence de fumées de peinture ou de solvant. Toutes les pièces du système du pulvérisateur, y compris la pompe, l’ensemble du tuyau, le pistolet de pulvérisation et les objets dans et autour de la zone de pulvérisation doivent être correctement reliés à la terre pour protéger contre les décharges d’électricité statique et les étincelles. N’utilisez que des tuyaux conducteurs ou reliés à la terre pour pulvérisateurs de peinture sous vide à haute pression, spécifiés par le fabricant.
5. Vérifiez que tous les conteneurs ou systèmes de stockage sont reliés à la terre pour éviter les décharges d’électricité statique.
6. Connectez à une prise électrique avec prise de terre et utilisez des rallonges électriques reliées à la terre. N’utilisez pas d’adaptateur 3 à 2.
7. N’utilisez pas de peinture ou de solvant contenant du halon, par exemple, le chlore, les agents antimoisissure à l’eau de Javel, le chlorure de méthylène et le trichloroéthane. Ils ne sont pas compatibles avec l’aluminium. Contactez le fournisseur de revêtements pour connaître la compatibilité du matériau avec l’aluminium.
8. La zone de pulvérisation doit toujours être bien aérée. Une bonne quantité d’air frais doit constamment traverser la zone de pulvérisation pour éviter les accumulations de vapeurs inflammables. Le système de pompage doit être placé dans une zone bien aérée. Ne pulvérisez pas le système de pompage.
9. Ne fumez pas dans la zone de pulvérisation.
10. N’actionnez pas d’interrupteurs électriques, de moteurs ou autres dispositifs produisant des étincelles dans la zone de pulvérisation.
11. Maintenez la propreté de la zone et veillez à ce qu’elle ne contienne pas de conteneurs de peinture ou de solvant, de chiffons et autres matières inflammables.
12. Sachez ce que contiennent la peinture et les solvants pulvérisés. Lisez les fiches de sécurité du matériel (MSDS) et les étiquettes apposées sur les conteneurs de peintures et de solvants. Respectez les consignes de sécurité du fabricant de peinture et de solvant.
13. Placez la pompe à une distance minimum de 7,62 mètres (25 pieds) de l’objet à pulvériser, dans une zone bien aérée (ajoutez de la longueur de tuyau si besoin est). Les vapeurs inflammables sont souvent plus lourdes que l’air. La zone près du sol doit être très bien aérée. La pompe contient des pièces qui produisent des arcs et émettent des étincelles pouvant enflammer les vapeurs.
14. Le plastique peut causer des étincelles d’électricité statique. N’accrochez aucun plastique dans une zone de pulvérisation fermée. N’utilisez pas de toiles de protection en plastique quand vous pulvérisez une matière inflammable.
15. Ayez un extincteur en bon état de fonctionnement à portée de main.
C. AVERTISSEMENT – Pour réduire le risque de
pénétration dans la peau :
DANGER : Blessure par injection – Le jet de fluide à haute pression
produit par cet équipement peut transpercer la peau et les tissus sous-jacents, ce qui produit de graves blessures et peut entraîner une amputation. Consultez immédiatement un médecin. NE TRAITEZ PAS UNE INJECTION COMME UNE SIMPLE COUPURE.
1. Ne dirigez pas le pistolet sur et ne pulvérisez pas les personnes ou les animaux.
2.
N’approchez pas les mains ni d’autres parties du corps
de la sortie du produit. Par exemple, ne tentez pas d’arrêter une fuite avec une partie du corps.
3. Utilisez toujours le protège-embout de la buse. Ne pulvérisez pas sans que le protège-embout de la buse ne soit installé.
4. Utilisez exclusivement un embout de buse spécifié par le fabricant.
5. Prenez garde quand vous nettoyez ou que vous changez les embouts de buse. Si l’embout se bouche pendant que vous pulvérisez, verrouillez TOUJOURS la détente du pistolet, arrêtez la pompe et libérez toute la pression avant de réparer ou de nettoyer l’embout ou le protecteur ou avant de changer d’embout. La pression n’est pas libérée par l’arrêt du moteur. La poignée du robinet-valve PRIME/SPRAY (AMORÇAGE/ PULVÉRISATION) doit être placée sur PRIME pour libérer la pression. Consultez la PROCÉDURE DE LIBÉRATION DE PRESSION décrite dans le manuel de la pompe.
Français
16 © Titan Tool Inc. Tous droits réservés.
Page 17
6. Ne laissez pas l’appareil sous tension ou sous pression
AVERTISSEMENT
ATTENTION
Prise de terre
Goupille de mise à la terre
Couvercle du boîtier de prise de terre
quand vous vous en éloignez. Quand vous n’utilisez pas l’appareil, éteignez-le et libérez la pression conformément aux instructions du fabricant.
7. La pulvérisation à haute pression peut injecter des toxines dans le corps et causer de graves blessures corporelles. Si une telle injection se produisait, consultez immédiatement un médecin.
8. Vérifiez les tuyaux et les pièces pour détecter des signes d’endommagement : une fuite peut injecter le produit dans la peau. Inspectez le tuyau avant chaque emploi. Changez tous les tuyaux ou pièces endommagés.
9. Ce système peut produire une pression de 3300 PSI /
22.8 MPa. N’utilisez que les pièces de rechange ou les accessoires spécifiés par le fabricant et ayant une pression nominale minimum de 3300 PSI. Ceci est valable pour les embouts de pulvérisation, les protecteurs de buse, les pistolets, les rallonges, les raccords et le tuyau.
10. Verrouillez toujours la détente quand vous ne pulvérisez pas. Vérifiez que le verrou de la détente fonctionne correctement.
11. Vérifiez que toutes les connexions sont bien serrées avant d’utiliser l’appareil.
12. Sachez comment arrêter l’appareil et le dépressuriser rapidement. Soyez bien familiarisé avec les commandes. La pression n’est pas libérée lorsque le moteur est arrêté. La poignée du robinet-valve PRIME/SPRAY (AMORÇAGE/PULVÉRISATION) doit être placée sur PRIME pour libérer la pression. Consultez la PROCÉDURE DE LIBÉRATION DE PRESSION décrite dans le manuel de la pompe.
13. Retirez toujours l’embout de pulvérisation avant de rincer ou de nettoyer le système.
12. Avant chaque emploi, vérifiez tous les tuyaux pour détecter d’éventuelles coupures, fuites, abrasion ou couvercle bombé. Vérifiez l’état ou le mouvement des accouplements. Changez immédiatement le tuyau si l’une de ces conditions est vérifiée. Ne réparez jamais un tuyau de peinture. Remplacez-le par un tuyau conducteur à haute pression.
13. Ne pulvérisez pas à l’extérieur par temps venteux.
14. Débranchez toujours le cordon électrique de la prise avant de travailler sur l’équipement.
Instructions de mise à la terre
Cet appareil doit être mis à la terre. La mise à la terre réduit les risques d'électrocution lors d'un court-circuit en permettant au courant de s'écouler par le fil de mise à la terre. Cet appareil est muni d'un cordon électrique avec fil de mise à la terre ainsi que d'une fiche de terre. La fiche doit être branchée sur une prise installée correctement et mise à la terre conformément à la réglementation et aux codes en vigueur.
DANGER — Une prise de terre mal branchée peut être à l'origine d'électrocutions. S'il s'avère nécessaire de réparer ou de remplacer le cordon électrique ou la fiche, ne pas brancher le fil vert de mise à la terre sur l'une ou l'autre des bornes à broche plate. Le fil recouvert d'un isolant vert avec ou sans rayures jaunes est le fil de mise à la terre et doit être branché sur la broche de mise à la terre.
Si vous ne comprenez pas les instructions de mise à la terre ou si vous n'êtes pas sûr que l'appareil est correctement mis à la terre, contactez un électricien agréé. Ne pas modifier la fiche d'origine. Si la prise ne convient pas à la fiche, faites installer la prise adéquate par un électricien agréé.
D. AVERTISSEMENT – Pour réduire le risque de blessure :
1. Portez toujours les gants, la protection oculaire, les vêtements et un respirateur ou masque appropriés quand vous peignez. Vapeurs dangereuses – Les peintures, solvants, insecticides et autres matières peuvent être dangereux s’ils sont inhalés ou entrent en contact avec le corps. Les vapeurs peuvent provoquer d’importantes nausées, une perte de connaissance ou un empoisonnement.
2.
Ne travaillez pas et ne pulvérisez pas près d’enfants.
Éloignez toujours les enfants de l’équipement.
3. Ne travaillez pas avec les bras au-dessus de la tête ni sur un support instable. Appuyez-vous bien sur les deux pieds pour toujours conserver l’équilibre.
4. Soyez attentif et regardez ce que vous faites.
5. N’utilisez pas l’appareil quand vous êtes fatigué ou sous l’influence de drogues ou d’alcool.
6. Ne faites pas de n?uds avec le tuyau et ne le tordez pas trop. Le tuyau à vide peut présenter des fuites suite à l’usure, les n?uds ou les mauvais traitements. Une fuite risque d’injecter du produit dans la peau.
7. N’exposez pas le tuyau à des températures ou des pressions supérieures à celles spécifiées par le fabricant.
8. N’utilisez pas le tuyau pour tirer ou soulever l’équipement.
9. Utilisez la plus basse pression possible pour rincer l’équipement.
10. Respectez tous les codes locaux, étatiques et nationaux qui régulent la ventilation, la prévention d’incendies et le fonctionnement.
11. Les normes de sécurité du gouvernement des États­Unis ont été adoptées dans la loi Occupational safety and Health Act (OSHA). Ces normes, en particulier la partie 1910 des Normes générales et la partie 1926 des Normes de construction, doivent être consultées.
Utiliser uniquement une rallonge à trois fils munie d'une fiche de terre dans une prise secteur mise à la terre correspondant au type de fiche de l'appareil. S'assurer que votre rallonge est en bon état. Lorsque vous utilisez une rallonge, assurez-vous qu'elle soit d'un calibre suffisant pour supporter l'intensité du courant requise par l'appareil. Une rallonge trop mince entraîne une chute de tension, une diminution de l'intensité et une surchauffe. Une rallonge de calibre 12 est recommandée. Si vous devez utiliser une rallonge à l’extérieur A après la désignation indiquant le type de cordon. Par exemple, la désignation SJTW-A indique que le cordon est conçu pour être utilisé à l’extérieur.
, celle-ci doit comprendre la marque W-
© Titan Tool Inc. Tous droits réservés. 17
Français
Page 18
Precauciones de seguridad
ADVERTENCIA
PRECAUCION
ADVERTENCIA
ADVERTENCIA
Este manual contiene información que debe leer y comprender antes de usar el equipo. Cuando se encuentre con uno de los siguientes símbolos, asegúrese de observar sus indicaciones de seguridad.
Este símbolo indica la existencia de un peligro potencial que puede causar lesiones graves o la muerte. Después del mismo se incluye información de seguridad importante.
Este símbolo indica la existencia de un peligro potencial para usted o el equipo. Después del mismo se incluye información importante que indica la forma de evitar daños al equipo o la forma de prevenir lesiones menores.
NOTA: los avisos contienen información importante,
A.
B. ADVERTENCIA – Para reducir el riesgo de incendio o
présteles especial atención.
INSTRUCCIONES DE SEGURIDAD IMPORTANTES
GUARDE ESTAS INSTRUCCIONES – Para reducir el riesgo de incendio o explosión, descarga eléctrica y daños a las personas, lea y comprenda todas las instrucciones incluidas en este manual. Familiarícese con los controles y con el uso adecuado del equipo.
explosión:
1. No pulverice materiales inflamables ni combustibles cerca de llamas desnudas, pilotos o fuentes de ignición como objetos calientes, cigarrillos, motores, equipos eléctricos o electrodomésticos. Evite producir chispas al conectar y desconectar los cables de alimentación.
2.
Para unidades que se vayan a utilizar con materiales
acuosos — No pulverice ni limpie con líquidos inflamables. Para su uso con líquidos acuosos solamente.
3. Para unidades que se vayan a utilizar solamente con materiales acuosos o de tipo de alcohol mineral con un punto de inflamación mínimo de 21 ºC (69,8 ºF) — No pulverice ni limpie con líquidos que tengan un punto de inflamación por debajo de 21 ºC (69,8 ºF). El punto de inflamación es la temperatura a la que un fluido puede producir vapor suficiente como para incendiarse.
4. La pintura o disolvente que pase por el equipo puede producir electricidad estática. La electricidad estática supone un riesgo de incendio o explosión en presencia de emanaciones de pintura o disolvente. Todas las piezas del sistema pulverizador, incluyendo la bomba, el conjunto de mangueras, la pistola pulverizadora y los objetos dentro y alrededor de la zona de pulverización se conectarán a tierra para protegerlos frente a descargas estáticas y chispas. Utilice solamente mangueras para pulverizadores de pintura airless (sin aire) de alta presión conductoras o con toma a tierra especificadas por el fabricante.
5. Compruebe que todos los recipientes y sistemas de recogida están conectados a tierra para evitar descargas eléctricas.
6. Conecte a una salida con toma a tierra y utilice cables alargadores puestos a tierra. No utilice un adaptador de 3 a 2.
7. No utilice pintura o disolvente que contenga hidrocarburos halogenados, como cloro, fungicida blanqueador, cloruro de metileno y tricloroetano. No son compatibles con el aluminio. Póngase en contacto con el proveedor del material para conocer su compatibilidad con el aluminio.
Español
8. Mantenga la zona de pulverización bien ventilada. Asegúrese de que circula aire fresco por la zona para evitar que se acumulen vapores inflamables en el aire de la zona de pulverización. Ponga el conjunto de la bomba en una zona bien ventilada. No pulverice el conjunto de la bomba.
9. No fume en la zona de pulverización.
10. No encienda interruptores de luces, motores ni productos similares que puedan producir chispas en la zona de pulverización.
11. Mantenga la zona limpia y despejada de botes de pintura y disolventes, trapos y otros materiales inflamables.
12. Infórmese del contenido de la pintura y de los disolventes que pulverice. Lea las hojas de datos sobre seguridad de los materiales (MSDS) y las etiquetas en los botes de pintura y disolvente. Siga las instrucciones de seguridad del fabricante de la pintura y del disolvente.
13. Coloque la bomba al menos a 7,62 metros (25 pies) del objeto que se va a pulverizar en una zona bien ventilada (añada más manguera si fuera necesario). Los vapores inflamables suelen ser más pesados que el aire. La zona del suelo debe estar muy bien ventilada. La bomba contiene piezas que forman arcos que producen chispas y pueden inflamar los vapores.
14. El plástico puede producir chispas estáticas. Nunca utilice plástico para cercar la zona de pulverización. No utilice cortinas de plástico mientras pulveriza material inflamable.
15. Deberá contar con equipos extintores de incendios que funcionen correctamente.
C. ADVERTENCIA – Para reducir el riesgo de daños en la
piel:
PELIGRO: Lesión causada por inyección. La corriente de líquido a
alta presión que produce este equipo puede perforar la piel y tejidos subcutáneos, pudiendo provocar graves lesiones y posibles amputaciones. Visite a un médico inmediatamente. NO TRATE UNA LESIÓN CAUSADA POR INYECCIÓN COMO UN SIMPLE CORTE.
1. No apunte con la pistola ni pulverice sobre ninguna persona ni animal.
2. Mantenga las manos y el resto del cuerpo lejos de la descarga. Por ejemplo, no trate de detener fugas con ninguna parte de su cuerpo.
3.
Utilice siempre el protector de la boquilla. No pulverice
sin el protector en su sitio.
4. Utilice solamente la boquilla especificada por el fabricante.
5. Tenga cuidado al limpiar y cambiar las boquillas. Si la boquilla se atasca durante la pulverización,
ponga SIEMPRE el seguro del gatillo de la pistola,
apague la bomba y libere toda la presión antes de reparar, limpiar el protector o la boquilla o cambiar la boquilla. La presión no se libera apagando el motor. Para liberar la presión hay que poner la manija de la válvula PRIME/SPRAY (cebar/pulverizar) en PRIME. Consulte el Procedimiento para liberar presión que se describe en el manual de la bomba.
6. No deje el aparato con corriente ni con presión cuando nadie esté pendiente de ella. Cuando no utilice el aparato, apáguelo y libere la presión siguiendo las instrucciones del fabricante.
7. La pulverización a alta presión puede inyectar toxinas en el cuerpo y producir daños graves en el mismo. En caso de que esto ocurra, visite a un médico inmediatamente.
8. Compruebe las mangueras y las piezas en busca de daños; una fuga puede inyectar material en la piel. Inspeccione la manguera antes de cada uso. Sustituya las mangueras o las piezas dañadas.
18 © Titan Tool Inc. Todos los derechos reservados.
Page 19
9. Este sistema es capaz de producir 3300 PSI / 22.8
ADVERTENCIA
PRECAUCION
Tomacorriente aterrado
Terminal de tierra
Tapa de la caja del tomacorriente aterrado
MPa. Utilice solamente piezas de repuesto o accesorios especificados por el fabricante y con una capacidad nominal de 3300 PSI como mínimo. Entre ellos se incluyen boquillas pulverizadoras, protectores para las boquillas, pistolas, alargadores, racores y mangueras.
10. Ponga siempre el seguro del gatillo cuando no esté pulverizando. Verifique que el seguro del gatillo funciona correctamente.
11. Antes de utilizar el aparato, verifique que todas las conexiones son seguras.
12. Aprenda a detener el aparato y a liberar la presión rápidamente. Familiarícese a conciencia con los controles. La presión no se libera apagando el motor. Para liberar la presión hay que poner la manija de la válvula PRIME/SPRAY (cebar/pulverizar) en PRIME. Consulte el Procedimiento para liberar presión que se describe en el manual de la bomba.
13. Quite siempre la boquilla pulverizadora antes de enjuagar o limpiar el sistema.
D. ADVERTENCIA – Para reducir el riesgo de lesiones:
1. Cuando pinte, lleve siempre guantes, protección para los ojos, ropa y un respirador o máscara adecuados. Vapores peligrosos: Las pinturas, disolventes, insecticidas y otros materiales pueden ser perjudiciales si se inhalan o entran en contacto con el cuerpo. Los vapores pueden producir nauseas intensas, desmayos o envenenamiento.
2. Nunca utilice el aparato ni pulverice cerca de niños. Mantenga el equipo alejado de los niños en todo momento.
3. No se estire demasiado ni se apoye sobre un soporte inestable. Mantenga los pies bien apoyados y el equilibrio en todo momento.
4.
No se distraiga y tenga cuidado con lo que hace.
5. No utilice el aparato si está fatigado o se encuentra bajo la influencia del alcohol o de las drogas.
6. No retuerza ni doble la manguera en exceso. En la manguera airless pueden aparecer fugas a causa del desgaste, de retorcimientos o de un mal uso. Una fuga puede inyectar material en la piel.
7. No exponga la manguera a temperaturas o presiones que superen las especificadas por el fabricante.
8. No utilice la manguera como elemento de fuerza para tirar del equipo o levantarlo.
9. Utilice la presión más baja posible para enjuagar el equipo.
10. Cumpla todos los reglamentos locales, estatales y nacionales pertinentes relativos a ventilación, prevención de incendios y funcionamiento.
11. Las normas sobre seguridad del gobierno de los Estados Unidos se han adoptado al amparo de la Ley de salud y seguridad ocupacional (OSHA). Deben consultarse tres normas, particularmente la sección 1910 de las Normas generales y la sección 1926 de las Normas sobre construcción.
12. Cada vez que vaya a utilizar el equipo, compruebe antes todas las mangueras en busca de cortes, fugas, abrasión o bultos en la cubierta. Compruebe el movimiento de los acoplamientos y si están dañados. Sustituya inmediatamente una manguera si descubre alguna de estas anomalías. No repare nunca una manguera de pintura. Sustitúyala por una manguera conductora a alta presión.
13. No pulverice al aire libre si hace viento.
14. Desenchufe siempre el cable antes de trabajar en el equipo.
Instrucciones para conectar a tierra
Este producto se debe conectar a tierra. En caso de que ocurra un corto circuito, la conexión a tierra reduce el riesgo de choque eléctrico al proporcionar un alambre de escape para la corriente eléctrica. Este producto está equipado con un cable que tiene un alambre de conexión a tierra con un enchufe de conexión a tierra apropiado. El enchufe se debe enchufar en una toma de corriente que se haya instalado y conectado a tierra debidamente, de acuerdo con todos los códigos y estatutos locales.
PELIGRO — Una instalación inapropiada del enchufe de conexión a tierra puede dar como resultado el que exista un riesgo de choque eléctrico. Si es necesario reparar o reemplazar el cable o el enchufe, no conecte el alambre de conexión a tierra a ninguno de los terminales de hoja planos. El alambre con aislamiento que tiene la superficie exterior de color verde con franjas amarillas o sin ellas es el alambre de conexión a tierra que debe conectarse al conector de conexión a tierra.
Verifique con un electricista o técnico de servicio calificado si las instrucciones para conectar a tierra no le han quedado completamente claras, o si duda que el producto haya quedado conectado a tierra de manera apropiada. No modifique el enchufe que se proporciona. Si el enchufe no entra en la toma de corriente, pídale a un electricista calificado que instale la toma apropiada.
Use solamente extensiones trifilares que tengan un enchufe de conexión a tierra de 3 hojas y un receptáculo de triple ranura que acepte el enchufe del producto. Asegúrese de que su extensión esté en buenas condiciones. Cuando use una extensión, asegúrese de usar una que sea lo suficientemente resistente como para soportar la corriente que descargue su producto. Un cable de un tamaño menor causará una caída de voltage en la línea que dará como resultado una pérdida de energía y un sobrecalenta|ôento. Se recomienda usar un cable de calibre 12. Si se utiliza un cable de extensión en el exterior después de la designación del tipo de cable. Por ejemplo, SJTW-A para indicar que el cable es apropiado para uso en exteriores.
, tiene que estar marcado con el sufijo W-A
© Titan Tool Inc. Todos los derechos reservados. 19
Español
Page 20
Parts List
12
13
1
3
6
5
7 8
9
10
4
11
2
18
19
20
22
21
23
24
25 26
27
16
17
15
14
High Rider Model
Main Assembly
20 © Titan Tool Inc. All rights reserved.
Page 21
Item Part # Description Quantity
1
3
4 5
2
6
7
8
9
10
2
1
2
3
4 5
6
1 704-181 Screw (includes washer and grommet)......4
2 704-232 Motor cover.................................................1
3 700-681 Screw..........................................................4
4 704-499 Power cord (skid)........................................1
704-553 Power cord (high rider)
5 704-229 Ground screw .............................................1
6 704-486 Screw..........................................................4
7 704-488 Pressure control knob.................................1
8 704-469 Xact Digital Control System assembly
(optional).....................................................1
9 704-467 Xact Digital Control system cover
(optional).....................................................1
10 704-487 Screw..........................................................2
11 704-300 Siphon/Return assembly (skid)...................1
12 704-599 Dust cover (for sprayers without Xact
Digital Control System)...............................1
13 704-473 Control panel cover (for sprayers without
Xact Digital Control System).......................1
Item
Part # Description Quantity
14 765-063 Strain relief (skid)........................................1
704-369 Strain relief (high rider)
15 704-331 Gasket ........................................................1
16 761-178 Hex screw ..................................................4
17 ---------- Skid assembly.............................................1
18 704-470 Control panel ..............................................1
19 704-538 Fluid section assembly (skid).......................1
704-571 Fluid section assembly (high rider)
20 704-117 Socket screw ..............................................2
21 704-304 Pail hook (high rider) ..................................1
22 763-552 Lock washer (high rider).............................2
23 710-033 Hex screw (high rider) ................................2
24 702-239 Return hose (high rider)..............................1
25 755-225 Siphon tube (high rider)..............................1
26 730-334 Hose clip (high rider) ..................................1
27 710-046 Inlet screen (high rider) .............................1
28 800-929 Fuse, 15A (not shown)................................1
Skid Assembly
Item Part # Description Quantity
1 700-761 Cord wrap ...................................................1
2 710-199 Plug.............................................................4
3 704-164 Leg, left.......................................................1
4 700-642 Screw..........................................................2
5 226-001 Lock nut ......................................................1
6 700-1043 Drip cup ......................................................1
7 704-244 Clip..............................................................1
8 704-243 Screw..........................................................1
9 704-163 Leg, right.....................................................1
10 761-188 Screw..........................................................2
704-179 Leg, left, complete
(includes items 1–4)
704-178 Leg, right, complete
(includes items 5–10)
Siphon/Return Assembly (P/N 704-300)
Item Part #
1 700-1023 Siphon tube assembly
2 704-263 Return hose ................................................1
3 700-805 Inlet screen .................................................1
4 704-121 O-ring..........................................................2
704-109 O-ring (for hot solvents, optional)
5 700-1024 Elbow ..........................................................1
6 704-127 Retaining clip ..............................................1
7 704-391 Return hose clip (not shown)......................1
Description Quantity
(includes items 3, 4, and 7) ........................1
© Titan Tool Inc. All rights reserved. 21
Page 22
Fluid Section Assembly (Skid P/N 704-538, High Rider 704-571)
23
24
25 26 27 28 29 30
9
8
11
12
10
7
1
2
3
4
5
14
13
15
16
17
18
19
6
21
22
20
Install upper packing
with raised lip and
O-ring facing down.
O-Ring
Raised Lip
Install lower packing
with the beveled
edge facing up.
Beveled Edge
NOTE: When using “hot” solvents, replace Viton valve
stem o-ring (item 27) with optional PTFE valve stem o-ring (P/N 700-897). Install using o-ring replacement tool (P/N 700-890).
22 © Titan Tool Inc. All rights reserved.
Page 23
Item Part # Description Quantity
3
1
4
5
2
7
6
8
9
10
11
12
1 730-508 Retainer nut ................................................1
2 700-587 Piston guide................................................1
3 704-564 Upper packing assembly with tool..............1
4 704-532 Pump block.................................................1
5 227-006 Outlet fitting.................................................1
6 704-547 Lower packing assembly ............................1
7 704-551 Piston rod....................................................1
8 704-642 Outlet cage (includes item 9.......................1
9 704-612 Crush washer..............................................1
10 762-144 Outlet valve ball ..........................................1
11 704-558 Outlet valve seat.........................................1
12 704-587 Outlet valve retainer ...................................1
13 755-186 Piston bushing ............................................1
14 700-821 Foot valve seal ...........................................1
15 730-510 Inlet cage ....................................................1
16 762-145 Foot valve ball ............................................1
17 762-137 Foot valve seat ...........................................1
18 762-058 O-ring, PTFE ..............................................1
19 704-054 Foot valve housing (skid)............................1
730-511 Foot valve housing (high rider)
20 700-421 Filter housing ..............................................1
Drive Assembly
Item Part # Description Quantity
21 540-030 Filter............................................................1
22 560-038 Seal.............................................................1
23 700-258 PRIME/SPRAY valve assembly..................1
24 700-697 Valve handle...............................................1
25 700-759 Groove pin ..................................................1
26 700-252 Cam base ...................................................1
27 700-721 Valve stem o-ring, Viton..............................1
700-897 Valve stem o-ring, PTFE (optional)
28 221-012 O-ring, Viton................................................1
29 222-012 O-ring, PTFE ..............................................1
30 700-537 Gasket ........................................................1
31 762-202 Packing tool (not shown) ............................1
704-560 Piston assembly (includes items 7–12)
704-586 Repacking kit (includes items 2, 3, 6, 8, 9,
10, 14, 16, and 18. Also included are packing grease P/N 700-203 and piston guide tool P/N 700-793)
Item Part # Description Quantity
1 704-380 ON/OFF Switch...........................................1
2 700-139 Screw..........................................................8
3 704-019 Front cover..................................................1
4 704-492 Transducer assembly (includes item 5)......1
5 704-584 Transducer o-ring .......................................1
6 704-588 Electronic pressure control (EPC) ..............1
7 704-589 Motor (without EPC) ...................................1
8 704-173 Crankshaft/gear assembly..........................1
9 704-174 Thrust washer.............................................1
Item
10 704-176 2nd stage gear............................................1
11 704-510 Pump housing.............................................1
12 700-2060 Slider assembly ..........................................1
13 704-548 Transducer jumper wire (not shown)..........1
14 730-260 Electronic pressure control
15 704-126 Electronic pressure control
16 704-594 Surge suppressor (not shown) ...................1
NOTE: All electrical work should be performed
by an authorized service center.
Part # Description Quantity
mounting screw (not shown).......................4
lock washer (not shown).............................4
© Titan Tool Inc. All rights reserved. 23
Page 24
Potentiometer
Fuse
Motor
Transducer
Transducer Jumper
Plug
WHITE
WHITE
WHITE
BLACK
BLACK
GREEN
Control Panel
Board
Surge
Suppressor
Electronic Pressure
Control (EPC)
J16
AC-Motor
AC-NeutAC-Line
AC-Motor
J9
J2 J1
J12 J7
Switch
Ground
High Rider Cart Assembly
1
2
3
5
4
(P/N 704-574)
Labels
Part # Description
313-1638 Front cover label 313-2706 Motor cover label 313-1673 Warning label
(injection/explosion) 313-1847 Shock hazard label 313-1906 Infinity motor label 313-2324 X-Lock label 313-2327 Xact Digital Control System label 313-2328 Xact Instruction label 313-2430 Transducer warning label
Item Part # Description Quantity
1 704-573 Cart weldment (includes item 5).................1
2 704-355 Cap .............................................................2
3 704-354 Spacer ........................................................4
4 704-353 Wheel..........................................................2
5 710-199 Plug.............................................................4
Electrical Schematic
NOTE: All electrical work should
be performed by an authorized service center.
24 © Titan Tool Inc. All rights reserved.
Page 25
Accessories
Tip Size Spray Material Filter Type
.011 – .013 Lacquers and stains 100 mesh filter
.015 – .019 Oil and latex 60 mesh filter
.021 – .026 Heavy bodied latex and blockfillers 30 mesh filter
Airless Tip Selection
Tips are selected by the orifice size and fan width. The proper selection is determined by the fan width required for a specific job and by the orifice size that will supply the desired amount of fluid and accomplish proper atomization.
For light viscosity fluids, smaller orifice tips generally are desired. For heavier viscosity materials, larger orifice tips are preferred. Please refer to the chart below.
NOTE: Do not exceed the sprayer's recommended tip
The following chart indicates the most common sizes and the appropriate materials to be sprayed.
Fan widths measuring 8" to 12" (20 to 30 cm) are preferred because they offer more control while spraying and are less likely to plug.
Liquid Shield Plus
Cleans and protects spray systems against rust, corrosion and premature wear. Now with -25º anti-freeze protection.
Piston Lube
Specially formulated to prevent materials from adhering to the piston rod, which becomes abrasive to the upper seals. Piston Lube will break down any material that may accumulate in the oil cup and keep it from drying.
size.
Part #
314-483...........4 ounce bottle
314-482...........1 quart bottle
Part #
314-481...........4 ounce bottle
314-480...........8 ounce bottle
Description
Description
Synergy Fine Finish Tips
• Perfect for all fine finish work
• Ideal for lacquers, stain, enamels, urethane, and clear top coats
• Increases standard tip life up to 80%
• Delivers up to a 27% finer atomization at lower pressures
• Increases transfer efficiency resulting in less overspray
Part No.
671-XXX ..........Synergy Fine Finish Tips
Description
WideSpray Reversible Tips
• Designed for high production applications
• Increase production up to 100%
• WideSpray will save time and make you more money
Part No.
661-XXXX .........WideSpray Reversible Tips
Description
I-Remote Universal Remote Control System
• Operates your sprayer from over 100 feet away
• Works through walls, trees and other obstacles
• Increase or decrease the pressure of the sprayer without climbing down off the ladder
Part No.
800-690...........I-Remote Control System
800-691...........I-Remote Control Only
800-692...........I-Remote Receiver Only
Description
Xact Digital Control System
The Xact Digital Control System is an optional add-on that increases the functionality of the sprayer. It consists of a display and four function keys. The display shows the user menu features that enable the user to become more productive and profitable
• X-Lock Security Features (Individualized Codes)
• Pressure Reading — Set Pressure and Working Pressure
• User Preset Keys
• Total Gallons Sprayed
• Resetable Job Gallon Counter
• Total On Time and Run Time
• Resetable On Time and Run Time
• Programmable Service Time (Hour Meter)
• Advanced Diagnostics
Part No.
704-555...........Xact Digital Control System with Cover
Description
LX-80IIAirless Gun
• 3600 PSI
• All metal construction
• In-handle filter
• High pressure swivel
Part No.
580-100...........LX-80II— 4 Finger Gun
581-085...........LX-80II— 2 Finger Gun
580-050...........LX-80II— 4 Finger GTH Kit
581-150...........LX-80II— 2 Finger GTH Kit
Description
S-3 Stainless Steel Airless Gun
• 3900 PSI
• Stainless Steel fluid passages
• High Pressure Swivel
• In-handle filter
• 4-finger trigger pull
Part No.
550-250...........S-3 — 4 Finger Gun
© Titan Tool Inc. All rights reserved. 25
Description
Miscellaneous
Part No.
490-012...........Hose Coupling, 1/4" x 1/4"
730-397...........High Pressure Fl. Gauge
314-171...........Lubriplate, 14 ounce individual
314-172...........Lubriplate, 6 lb. can
700-1037..........Electrostatic discharge (ESD) wrist strap
Description
Page 26
Notes
26 © Titan Tool Inc. All rights reserved.
Page 27
Notes
© Titan Tool Inc. All rights reserved. 27
Page 28
Warranty
United States Sales & Service
1-800-526-5362
Fax 1-800-528-4826
107 Bauer Drive
Oakland, NJ 07436
www.titantool.com
Canadian Branch
1-800-565-8665
Fax 1-905-856-8496
200 Trowers Road, Unit 7B
Woodbridge, Ontario L4L 5Z8
International
1-201-337-1240
Fax 1-201-405-7449
107 Bauer Drive
Oakland, NJ 07436 USA
Titan Tool, Inc., (“Titan”) warrants that at the time of delivery to the original purchaser for use (“End User”), the equipment covered by this warranty is free from defects in material and workmanship. With the exception of any special, limited, or extended warranty published by Titan, Titan’s obligation under this warranty is limited to replacing or repairing without charge those parts which, to Titan’s reasonable satisfaction, are shown to be defective within twelve (12) months after sale to the End User. This warranty applies only when the unit is installed and operated in accordance with the recommendations and instructions of Titan.
This warranty does not apply in the case of damage or wear caused by abrasion, corrosion or misuse, negligence, accident, faulty installation, substitution of non-Titan component parts, or tampering with the unit in a manner to impair normal operation.
Defective parts are to be returned to an authorized Titan sales/service outlet. All transportation charges, including return to the factory, if necessary, are to be borne and prepaid by the End User. Repaired or replaced equipment will be returned to the End User transportation prepaid.
THERE IS NO OTHER EXPRESS WARRANTY. TITAN HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING, BUT NOT LIMITED TO, THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, TO THE EXTENT PERMITTED BY LAW. THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD SPECIFIED IN THE EXPRESS WARRANTY. IN NO CASE SHALL TITAN LIABILITY EXCEED THE AMOUNT OF THE PURCHASE PRICE. LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
TITAN MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY TITAN. THOSE ITEMS SOLD, BUT NOT MANUFACTURED BY TITAN (SUCH AS GAS ENGINES, SWITCHES, HOSES, ETC.) ARE SUBJECT TO THE WARRANTY, IF ANY, OF THEIR MANUFACTURER. TITAN WILL PROVIDE THE PURCHASER WITH REASONABLE ASSISTANCE IN MAKING ANY CLAIM FOR BREACH OF THESE WARRANTIES.
Patents
These products are covered by one or more of the following U.S. patents:
6,031,352 5,848,566 5,769,321 5,725,364 5,671,656 5,435,697 5,228,842 5,346,037 5,252,210 5,217,238 5,192,425 4,908,538 4,768,929 4,744,571 D384,676 6,179,222 5,934,883 4,723,892
Material Safety Data Sheets (MSDS) are available on Titan’s website or by calling Customer Service.
28 © Titan Tool Inc. All rights reserved.
Loading...